{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_2246"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_2246","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Design and numerical investigations of a counter-rotating axial compressor for a geothermal power plant application","abstract":"Geothermal provides a steady source of energy unlike other renewable sources, however, there are non-condensable gases (NCG's) that need to be removed before the steam enters the turbine/generator or the efficiency suffers. By utilizing a multistage counter-rotating axial compressor with integrated composite wound impellers the process of removing NCG's could be significantly improved. The novel composite impeller design provides a high level of corrosion resistance, a good strength to weight ratio, reduced size, and reduced manufacturing and maintenance costs. This thesis focuses on the design of the first 3 stages of a multistage counter-rotating axial compressor with integrated composite wound impellers for NCG removal. Because of the novel technique, an unusual set of constraints required a simplified 1 and 2D design methodology to be developed and investigated through CFD. The results indicate that by utilizing constant thickness blades with constant shroud radius (to ease manufacturing difficulties) a total pressure ratio of 1.37 with a total polytropic efficiency of 89.81% could be achieved.","abstract_html":"Geothermal provides a steady source of energy unlike other renewable sources, however, there are non-condensable gases (NCG&#x27;s) that need to be removed before the steam enters the turbine/generator or the efficiency suffers. By utilizing a multistage counter-rotating axial compressor with integrated composite wound impellers the process of removing NCG&#x27;s could be significantly improved. The novel composite impeller design provides a high level of corrosion resistance, a good strength to weight ratio, reduced size, and reduced manufacturing and maintenance costs. This thesis focuses on the design of the first 3 stages of a multistage counter-rotating axial compressor with integrated composite wound impellers for NCG removal. Because of the novel technique, an unusual set of constraints required a simplified 1 and 2D design methodology to be developed and investigated through CFD. The results indicate that by utilizing constant thickness blades with constant shroud radius (to ease manufacturing difficulties) a total pressure ratio of 1.37 with a total polytropic efficiency of 89.81% could be achieved.","abstract_has_math":false,"creators":["Qualman, Thomas, II"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mueller, Norbert","Wichman, Indrek","Engeda, Abraham"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-18T17:44:40Z","subjects":["Axial flow compressors","Geothermal power plants"],"languages":["English"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:2246","isbn:9781303623837","isbn:1303623838","oclc:931760886","umi:1549709","local:QualmanII_grad.msu_0128N_12601"],"render_values":[{"text":"etd:2246","href":null,"code":true},{"text":"isbn:9781303623837","href":null,"code":true},{"text":"isbn:1303623838","href":null,"code":true},{"text":"oclc:931760886","href":null,"code":true},{"text":"umi:1549709","href":null,"code":true},{"text":"local:QualmanII_grad.msu_0128N_12601","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_2246","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mueller, Norbert","Wichman, Indrek","Engeda, Abraham"]},{"key":"dc:creator","label":"Author","values":["Qualman, Thomas, II"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Text","Theses"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Axial flow compressors","Geothermal power plants"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:2246","isbn:9781303623837","isbn:1303623838","oclc:931760886","umi:1549709","local:QualmanII_grad.msu_0128N_12601"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Geothermal provides a steady source of energy unlike other renewable sources, however, there are non-condensable gases (NCG's) that need to be removed before the steam enters the turbine/generator or the efficiency suffers. By utilizing a multistage counter-rotating axial compressor with integrated composite wound impellers the process of removing NCG's could be significantly improved. The novel composite impeller design provides a high level of corrosion resistance, a good strength to weight ratio, reduced size, and reduced manufacturing and maintenance costs. This thesis focuses on the design of the first 3 stages of a multistage counter-rotating axial compressor with integrated composite wound impellers for NCG removal. Because of the novel technique, an unusual set of constraints required a simplified 1 and 2D design methodology to be developed and investigated through CFD. The results indicate that by utilizing constant thickness blades with constant shroud radius (to ease manufacturing difficulties) a total pressure ratio of 1.37 with a total polytropic efficiency of 89.81% could be achieved.","Thesis (M.S.)--Michigan State University. Mechanical Engineering - Master of Science, 2013","Includes bibliographical references (pages 53-55)"]},{"key":"dc:format","label":"Dc Format","values":["xii, 55 pages","application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and numerical investigations of a counter-rotating axial compressor for a geothermal power plant application"]}]}],"canonical_facts":{"dc:contributor":["Mueller, Norbert","Wichman, Indrek","Engeda, Abraham"],"dc:creator":["Qualman, Thomas, II"],"dc:date":["2013"],"dc:description":["Geothermal provides a steady source of energy unlike other renewable sources, however, there are non-condensable gases (NCG's) that need to be removed before the steam enters the turbine/generator or the efficiency suffers. By utilizing a multistage counter-rotating axial compressor with integrated composite wound impellers the process of removing NCG's could be significantly improved. The novel composite impeller design provides a high level of corrosion resistance, a good strength to weight ratio, reduced size, and reduced manufacturing and maintenance costs. This thesis focuses on the design of the first 3 stages of a multistage counter-rotating axial compressor with integrated composite wound impellers for NCG removal. Because of the novel technique, an unusual set of constraints required a simplified 1 and 2D design methodology to be developed and investigated through CFD. The results indicate that by utilizing constant thickness blades with constant shroud radius (to ease manufacturing difficulties) a total pressure ratio of 1.37 with a total polytropic efficiency of 89.81% could be achieved.","Thesis (M.S.)--Michigan State University. Mechanical Engineering - Master of Science, 2013","Includes bibliographical references (pages 53-55)"],"dc:format":["xii, 55 pages","application/pdf"],"dc:identifier":["etd:2246","isbn:9781303623837","isbn:1303623838","oclc:931760886","umi:1549709","local:QualmanII_grad.msu_0128N_12601"],"dc:language":["English"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Axial flow compressors","Geothermal power plants"],"dc:title":["Design and numerical investigations of a counter-rotating axial compressor for a geothermal power plant application"],"dc:type":["Text","Theses"]},"updated_at":"2026-11-18T17:44:40Z"}