{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_44"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_44","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Reducing the number of ultrasound array elements with the matrix pencil method","abstract":"Phased arrays are diversely applied with some specific areas including biomedical imaging and therapy, non-destructive testing, radar and sonar. In this thesis, the matrix pencil method is employed to reduce the number of elements in a linear ultrasound phased array. The non-iterative, linear method begins with a specified pressure beam pattern, reduces the dimensionality of the problem, then calculates the element locations and apodization of a reduced array. Computer simulations demonstrate a close comparison between the initial array beam pattern and the reduced array beam pattern for four different linear arrays. The number of elements in a broadside-steered linear array is shown to decrease by approximately 50% with the reduced array beam pattern closely approximating the initial array beam pattern in the far-field. While the method returns a slightly tapered spacing between elements, for the arrays considered, replacing the tapered spacing with a suitably-selected uniform spacing provides very little change in the main beam and low-angle side lobes.","abstract_html":"Phased arrays are diversely applied with some specific areas including biomedical imaging and therapy, non-destructive testing, radar and sonar. In this thesis, the matrix pencil method is employed to reduce the number of elements in a linear ultrasound phased array. The non-iterative, linear method begins with a specified pressure beam pattern, reduces the dimensionality of the problem, then calculates the element locations and apodization of a reduced array. Computer simulations demonstrate a close comparison between the initial array beam pattern and the reduced array beam pattern for four different linear arrays. The number of elements in a broadside-steered linear array is shown to decrease by approximately 50% with the reduced array beam pattern closely approximating the initial array beam pattern in the far-field. While the method returns a slightly tapered spacing between elements, for the arrays considered, replacing the tapered spacing with a suitably-selected uniform spacing provides very little change in the main beam and low-angle side lobes.","abstract_has_math":false,"creators":["Sales, Kirk L."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["McGough, Robert","Radha, Hayder","Aviyente, Selin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-18T18:48:03Z","subjects":["Matrix pencils","Phased array antennas"],"languages":["English"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:44","isbn:9781267596932","isbn:1267596937","oclc:931869492","umi:1518360","local:Sales_grad.msu_0128N_11462"],"render_values":[{"text":"etd:44","href":null,"code":true},{"text":"isbn:9781267596932","href":null,"code":true},{"text":"isbn:1267596937","href":null,"code":true},{"text":"oclc:931869492","href":null,"code":true},{"text":"umi:1518360","href":null,"code":true},{"text":"local:Sales_grad.msu_0128N_11462","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/vj3r-5095","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/vj3r-5095","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_44","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["McGough, Robert","Radha, Hayder","Aviyente, Selin"]},{"key":"dc:creator","label":"Author","values":["Sales, Kirk L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Text","Theses"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Matrix pencils","Phased array antennas"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:44","isbn:9781267596932","isbn:1267596937","oclc:931869492","umi:1518360","local:Sales_grad.msu_0128N_11462","https://doi.org/doi:10.25335/vj3r-5095"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Phased arrays are diversely applied with some specific areas including biomedical imaging and therapy, non-destructive testing, radar and sonar. In this thesis, the matrix pencil method is employed to reduce the number of elements in a linear ultrasound phased array. The non-iterative, linear method begins with a specified pressure beam pattern, reduces the dimensionality of the problem, then calculates the element locations and apodization of a reduced array. Computer simulations demonstrate a close comparison between the initial array beam pattern and the reduced array beam pattern for four different linear arrays. The number of elements in a broadside-steered linear array is shown to decrease by approximately 50% with the reduced array beam pattern closely approximating the initial array beam pattern in the far-field. While the method returns a slightly tapered spacing between elements, for the arrays considered, replacing the tapered spacing with a suitably-selected uniform spacing provides very little change in the main beam and low-angle side lobes.","Thesis (M.S.)--Michigan State University. Electrical Engineering, 2012","Includes bibliographical references (pages 79-80)"]},{"key":"dc:format","label":"Dc Format","values":["viii, 80 pages","application/pdf"]},{"key":"dc:title","label":"Title","values":["Reducing the number of ultrasound array elements with the matrix pencil method"]}]}],"canonical_facts":{"dc:contributor":["McGough, Robert","Radha, Hayder","Aviyente, Selin"],"dc:creator":["Sales, Kirk L."],"dc:date":["2012"],"dc:description":["Phased arrays are diversely applied with some specific areas including biomedical imaging and therapy, non-destructive testing, radar and sonar. In this thesis, the matrix pencil method is employed to reduce the number of elements in a linear ultrasound phased array. The non-iterative, linear method begins with a specified pressure beam pattern, reduces the dimensionality of the problem, then calculates the element locations and apodization of a reduced array. Computer simulations demonstrate a close comparison between the initial array beam pattern and the reduced array beam pattern for four different linear arrays. The number of elements in a broadside-steered linear array is shown to decrease by approximately 50% with the reduced array beam pattern closely approximating the initial array beam pattern in the far-field. While the method returns a slightly tapered spacing between elements, for the arrays considered, replacing the tapered spacing with a suitably-selected uniform spacing provides very little change in the main beam and low-angle side lobes.","Thesis (M.S.)--Michigan State University. Electrical Engineering, 2012","Includes bibliographical references (pages 79-80)"],"dc:format":["viii, 80 pages","application/pdf"],"dc:identifier":["etd:44","isbn:9781267596932","isbn:1267596937","oclc:931869492","umi:1518360","local:Sales_grad.msu_0128N_11462","https://doi.org/doi:10.25335/vj3r-5095"],"dc:language":["English"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Matrix pencils","Phased array antennas"],"dc:title":["Reducing the number of ultrasound array elements with the matrix pencil method"],"dc:type":["Text","Theses"]},"updated_at":"2026-11-18T18:48:03Z"}