{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_51241"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_51241","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"An electrochemical process for decentralized treatment of high-strength wastewater","abstract":"As water shortages grow increasingly common worldwide, the need to explore decentralized wastewater treatment options to address water pollution has also increased. Electrocoagulation (EC) is a potential technology for decentralized treatment systems due to its convenience and effectiveness. This study investigated the development of a pilot-scale electrocoagulation treatment system to treat source-separated blackwater. Bench-scale EC experiments effectively removed COD, TP, and turbidity. Pulse-width modulation also proved capable of decreasing the energy demand of EC. However, NH3-N was not removed effectively. Bench-scale air stripping experiments revealed that an NH3-N removal efficiency of 67.7% was achievable by increasing the pH of the electrocoagulation-treated blackwater to 11 with calcium hydroxide. In addition, pilot-scale EC experiments showed that utilizing electroflotation with sludge separation units is an essential mechanism for separating solids from the liquid phase of the EC effluent. The pilot-scale study also demonstrated that reducing the distance between electrodes decreases the energy demand of the treatment. Improvements to the pilot-scale EC treatment system decreased the EC reactor's power consumption to 2.64 Wh/L blackwater and reduced the COD, TP, TN, and TSS in the treated water by 90.3%, 98.4%, 85.1%, and 94.8%, respectively. An economic assessment concluded that the treatment system could treat 2,720 L of blackwater per day at a treatment cost of $5.65 per day. A sensitivity analysis showed that a 25% reduction in CapEx could reduce the average treatment cost by 21%, from $5.65/1000 L to $4.50/1000 L.","abstract_html":"As water shortages grow increasingly common worldwide, the need to explore decentralized wastewater treatment options to address water pollution has also increased. Electrocoagulation (EC) is a potential technology for decentralized treatment systems due to its convenience and effectiveness. This study investigated the development of a pilot-scale electrocoagulation treatment system to treat source-separated blackwater. Bench-scale EC experiments effectively removed COD, TP, and turbidity. Pulse-width modulation also proved capable of decreasing the energy demand of EC. However, NH3-N was not removed effectively. Bench-scale air stripping experiments revealed that an NH3-N removal efficiency of 67.7% was achievable by increasing the pH of the electrocoagulation-treated blackwater to 11 with calcium hydroxide. In addition, pilot-scale EC experiments showed that utilizing electroflotation with sludge separation units is an essential mechanism for separating solids from the liquid phase of the EC effluent. The pilot-scale study also demonstrated that reducing the distance between electrodes decreases the energy demand of the treatment. Improvements to the pilot-scale EC treatment system decreased the EC reactor&#x27;s power consumption to 2.64 Wh/L blackwater and reduced the COD, TP, TN, and TSS in the treated water by 90.3%, 98.4%, 85.1%, and 94.8%, respectively. An economic assessment concluded that the treatment system could treat 2,720 L of blackwater per day at a treatment cost of $5.65 per day. A sensitivity analysis showed that a 25% reduction in CapEx could reduce the average treatment cost by 21%, from $5.65/1000 L to $4.50/1000 L.","abstract_has_math":true,"creators":["Aburto Vazquez, Gustavo"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Liao, Wei","Liu, Yan","Dusenbury, James"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-18T18:57:59Z","subjects":["Chemical engineering","Environmental engineering","Water-supply--Management"],"languages":["English"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:51241","isbn:9798379562977","oclc:on1396767612","oclc:1396767612","umi:30493549","local:AburtoVazquez_grad.msu_0128N_19830"],"render_values":[{"text":"etd:51241","href":null,"code":true},{"text":"isbn:9798379562977","href":null,"code":true},{"text":"oclc:on1396767612","href":null,"code":true},{"text":"oclc:1396767612","href":null,"code":true},{"text":"umi:30493549","href":null,"code":true},{"text":"local:AburtoVazquez_grad.msu_0128N_19830","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/3xkg-y677","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/3xkg-y677","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_51241","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Liao, Wei","Liu, Yan","Dusenbury, James"]},{"key":"dc:creator","label":"Author","values":["Aburto Vazquez, Gustavo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Text","Theses"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical engineering","Environmental engineering","Water-supply--Management"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:51241","isbn:9798379562977","oclc:on1396767612","oclc:1396767612","umi:30493549","local:AburtoVazquez_grad.msu_0128N_19830","https://doi.org/doi:10.25335/3xkg-y677"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["As water shortages grow increasingly common worldwide, the need to explore decentralized wastewater treatment options to address water pollution has also increased. Electrocoagulation (EC) is a potential technology for decentralized treatment systems due to its convenience and effectiveness. This study investigated the development of a pilot-scale electrocoagulation treatment system to treat source-separated blackwater. Bench-scale EC experiments effectively removed COD, TP, and turbidity. Pulse-width modulation also proved capable of decreasing the energy demand of EC. However, NH3-N was not removed effectively. Bench-scale air stripping experiments revealed that an NH3-N removal efficiency of 67.7% was achievable by increasing the pH of the electrocoagulation-treated blackwater to 11 with calcium hydroxide. In addition, pilot-scale EC experiments showed that utilizing electroflotation with sludge separation units is an essential mechanism for separating solids from the liquid phase of the EC effluent. The pilot-scale study also demonstrated that reducing the distance between electrodes decreases the energy demand of the treatment. Improvements to the pilot-scale EC treatment system decreased the EC reactor's power consumption to 2.64 Wh/L blackwater and reduced the COD, TP, TN, and TSS in the treated water by 90.3%, 98.4%, 85.1%, and 94.8%, respectively. An economic assessment concluded that the treatment system could treat 2,720 L of blackwater per day at a treatment cost of $5.65 per day. A sensitivity analysis showed that a 25% reduction in CapEx could reduce the average treatment cost by 21%, from $5.65/1000 L to $4.50/1000 L.","Thesis (M.S.)--Michigan State University. Biosystems Engineering, 2023","Includes bibliographical references"]},{"key":"dc:format","label":"Dc Format","values":["227 pages","application/pdf"]},{"key":"dc:title","label":"Title","values":["An electrochemical process for decentralized treatment of high-strength wastewater"]}]}],"canonical_facts":{"dc:contributor":["Liao, Wei","Liu, Yan","Dusenbury, James"],"dc:creator":["Aburto Vazquez, Gustavo"],"dc:date":["2023"],"dc:description":["As water shortages grow increasingly common worldwide, the need to explore decentralized wastewater treatment options to address water pollution has also increased. Electrocoagulation (EC) is a potential technology for decentralized treatment systems due to its convenience and effectiveness. This study investigated the development of a pilot-scale electrocoagulation treatment system to treat source-separated blackwater. Bench-scale EC experiments effectively removed COD, TP, and turbidity. Pulse-width modulation also proved capable of decreasing the energy demand of EC. However, NH3-N was not removed effectively. Bench-scale air stripping experiments revealed that an NH3-N removal efficiency of 67.7% was achievable by increasing the pH of the electrocoagulation-treated blackwater to 11 with calcium hydroxide. In addition, pilot-scale EC experiments showed that utilizing electroflotation with sludge separation units is an essential mechanism for separating solids from the liquid phase of the EC effluent. The pilot-scale study also demonstrated that reducing the distance between electrodes decreases the energy demand of the treatment. Improvements to the pilot-scale EC treatment system decreased the EC reactor's power consumption to 2.64 Wh/L blackwater and reduced the COD, TP, TN, and TSS in the treated water by 90.3%, 98.4%, 85.1%, and 94.8%, respectively. An economic assessment concluded that the treatment system could treat 2,720 L of blackwater per day at a treatment cost of $5.65 per day. A sensitivity analysis showed that a 25% reduction in CapEx could reduce the average treatment cost by 21%, from $5.65/1000 L to $4.50/1000 L.","Thesis (M.S.)--Michigan State University. Biosystems Engineering, 2023","Includes bibliographical references"],"dc:format":["227 pages","application/pdf"],"dc:identifier":["etd:51241","isbn:9798379562977","oclc:on1396767612","oclc:1396767612","umi:30493549","local:AburtoVazquez_grad.msu_0128N_19830","https://doi.org/doi:10.25335/3xkg-y677"],"dc:language":["English"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Chemical engineering","Environmental engineering","Water-supply--Management"],"dc:title":["An electrochemical process for decentralized treatment of high-strength wastewater"],"dc:type":["Text","Theses"]},"updated_at":"2026-11-18T18:57:59Z"}