{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52134"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52134","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"CARBON-BASED MICROELECTRODE DEVELOPMENT FOR ENVIRONMENTAL MONITORING SYSTEM","abstract":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","abstract_html":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","abstract_has_math":false,"creators":["Banna, G M Hasan Ul"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["LI, Wen WL","Hogan, Tim TH","Fan, Qi Hua QF","Zhang, Wei WZ","Siegenthaler, James JS"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T18:58:52Z","subjects":["Electrical engineering","Materials Science","Chemistry"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52134","local:Banna_grad.msu_0128D_21020"],"render_values":[{"text":"etd:52134","href":null,"code":true},{"text":"local:Banna_grad.msu_0128D_21020","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/gchd-2247","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/gchd-2247","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52134","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["LI, Wen WL","Hogan, Tim TH","Fan, Qi Hua QF","Zhang, Wei WZ","Siegenthaler, James JS"]},{"key":"dc:creator","label":"Author","values":["Banna, G M Hasan Ul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering","Materials Science","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52134","local:Banna_grad.msu_0128D_21020","https://doi.org/doi:10.25335/gchd-2247"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","Analysis of trace-level metals in environmental samples (e.g., soil, water, and plant samples) is essential for assessing environmental quality and food safety. This dissertation reports a non-toxic, eco-friendly, and cost-effective sensing method, capable of in-situ detection of microgram per liter (μg/L) levels of heavy metal ions in plant and soil solutions using carbon-based electrodes, including carbon fiber electrodes (CFEs) and boron-doped diamond electrodes (BDDs). The electrochemical behaviors of the CFEs and BDDs were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. As proof of principle, the CFEs and BDDs were validated for sensing selected heavy metals in buffer solutions as well as in extracted plant and soil solutions using differential pulse anodic stripping voltammetry (DP-ASV). The ideal pH range for heavy metal detection was also extensively investigated and was found to be between pH 4.0 and pH 5.0. Experimental results confirm that the CFEs were able to simultaneously measure cadmium (Cd), lead (Pb), and mercury (Hg) with a limit of detection (LOD) of 2.10 μg/L in buffer solution with an effective area (Aeff) of 0.123 cm2, showcasing good selectivity and sensitivity. On the other hand, the BDD electrodes showed simultaneous measurement of these metals with an LOD of 17.34 μg/L in buffer solution with Aeff of 0.122 mm2. Besides, BDD offers precise control over the fabrication by utilizing a microfabrication facility. Overall, the integration of these sensors with a microfluidics system lays a better foundation for long-term, in-situ, and stable electrochemical analysis for aqueous environment matrices.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (95 p.) : ill."]},{"key":"dc:title","label":"Title","values":["CARBON-BASED MICROELECTRODE DEVELOPMENT FOR ENVIRONMENTAL MONITORING SYSTEM"]}]}],"canonical_facts":{"dc:contributor":["LI, Wen WL","Hogan, Tim TH","Fan, Qi Hua QF","Zhang, Wei WZ","Siegenthaler, James JS"],"dc:creator":["Banna, G M Hasan Ul"],"dc:date":["2025"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","Analysis of trace-level metals in environmental samples (e.g., soil, water, and plant samples) is essential for assessing environmental quality and food safety. This dissertation reports a non-toxic, eco-friendly, and cost-effective sensing method, capable of in-situ detection of microgram per liter (μg/L) levels of heavy metal ions in plant and soil solutions using carbon-based electrodes, including carbon fiber electrodes (CFEs) and boron-doped diamond electrodes (BDDs). The electrochemical behaviors of the CFEs and BDDs were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. As proof of principle, the CFEs and BDDs were validated for sensing selected heavy metals in buffer solutions as well as in extracted plant and soil solutions using differential pulse anodic stripping voltammetry (DP-ASV). The ideal pH range for heavy metal detection was also extensively investigated and was found to be between pH 4.0 and pH 5.0. Experimental results confirm that the CFEs were able to simultaneously measure cadmium (Cd), lead (Pb), and mercury (Hg) with a limit of detection (LOD) of 2.10 μg/L in buffer solution with an effective area (Aeff) of 0.123 cm2, showcasing good selectivity and sensitivity. On the other hand, the BDD electrodes showed simultaneous measurement of these metals with an LOD of 17.34 μg/L in buffer solution with Aeff of 0.122 mm2. Besides, BDD offers precise control over the fabrication by utilizing a microfabrication facility. Overall, the integration of these sensors with a microfluidics system lays a better foundation for long-term, in-situ, and stable electrochemical analysis for aqueous environment matrices.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (95 p.) : ill."],"dc:identifier":["etd:52134","local:Banna_grad.msu_0128D_21020","https://doi.org/doi:10.25335/gchd-2247"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Electrical engineering","Materials Science","Chemistry"],"dc:title":["CARBON-BASED MICROELECTRODE DEVELOPMENT FOR ENVIRONMENTAL MONITORING SYSTEM"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:58:52Z"}