{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52551"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52551","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"ALGORITHMS TO ASSESS THE STRUCTURAL AND FUNCTIONAL CHANGES AT THE TISSUE ELECTRODE INTERFACE THROUGH THE ANALYSIS OF GENE EXPRESSION, METRICS OF ELECTROPHYSIOLOGY, AND ASTROCYTE MORPHOLOGY","abstract":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","abstract_html":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","abstract_has_math":false,"creators":["Saxena, Akash"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Purcell, Erin EP","Li, Tongtong TTL","LI, Wen WL","Qui, Zhen ZQ"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T18:59:06Z","subjects":["Electrical engineering","Neurosciences","Bioengineering"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52551","local:Saxena_grad.msu_0128D_21165"],"render_values":[{"text":"etd:52551","href":null,"code":true},{"text":"local:Saxena_grad.msu_0128D_21165","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/pvex-yd61","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/pvex-yd61","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52551","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Purcell, Erin EP","Li, Tongtong TTL","LI, Wen WL","Qui, Zhen ZQ"]},{"key":"dc:creator","label":"Author","values":["Saxena, Akash"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering","Neurosciences","Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52551","local:Saxena_grad.msu_0128D_21165","https://doi.org/doi:10.25335/pvex-yd61"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","Intracortical neural implants (ICNTs) are a powerful tool to treat and study neurological disorders.The performance of these implants depends on successful recording and stimulation for extended periods (up to years). This requires the recorded signal to remain consistent throughout implantation, or, from the perspective of providing stimulation, the stimulation with the same parameters should exhibit similar effects. This doesn’t hold true for ICNTs; the recorded signals exhibit intra-day variability, loss of signal quality, and potential desensitization to stimulation over chronic periods. The biological tissue response is a significant factor contributing to the loss of recording quality and signal instability for intracortical neural implants at chronic time points. Neuronal death and the presence of astrocytes around the implant are quantified to measure the strength of the tissue response to the implanted electrode. The usual trend observed is increasing neuronal death, the presence of astrocytes near the implant, and the formation of a glial sheath around the implant at chronic time points. The biocompatibility of available neural implants is primarily judged based on these two metrics. These metrics have guided various designs to reduce the tissue response, lowering both astrocytic and neuronal death and density around the implant. However, the tissue response is still triggered, and signal instability remains problematic. This leads us to believe that conventional metrics alone are insufficient in guiding implant design. Other metrics must be uncovered to complete the parameter space governing the biological tissue response to neural implants. The goal of this thesis is to create computational pipelines using signal processing, image processing, and data analysis methods to (1) better understand the interaction between the tissue and neural implant, (2) uncover variables that might affect the recording quality of the implant, and (3) potentially guide future neural implant design from the perspective of gene expression, metrics of extracellular recordings, and astrocyte morphology.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (141 p.) : ill."]},{"key":"dc:title","label":"Title","values":["ALGORITHMS TO ASSESS THE STRUCTURAL AND FUNCTIONAL CHANGES AT THE TISSUE ELECTRODE INTERFACE THROUGH THE ANALYSIS OF GENE EXPRESSION, METRICS OF ELECTROPHYSIOLOGY, AND ASTROCYTE MORPHOLOGY"]}]}],"canonical_facts":{"dc:contributor":["Purcell, Erin EP","Li, Tongtong TTL","LI, Wen WL","Qui, Zhen ZQ"],"dc:creator":["Saxena, Akash"],"dc:date":["2025"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2025","Intracortical neural implants (ICNTs) are a powerful tool to treat and study neurological disorders.The performance of these implants depends on successful recording and stimulation for extended periods (up to years). This requires the recorded signal to remain consistent throughout implantation, or, from the perspective of providing stimulation, the stimulation with the same parameters should exhibit similar effects. This doesn’t hold true for ICNTs; the recorded signals exhibit intra-day variability, loss of signal quality, and potential desensitization to stimulation over chronic periods. The biological tissue response is a significant factor contributing to the loss of recording quality and signal instability for intracortical neural implants at chronic time points. Neuronal death and the presence of astrocytes around the implant are quantified to measure the strength of the tissue response to the implanted electrode. The usual trend observed is increasing neuronal death, the presence of astrocytes near the implant, and the formation of a glial sheath around the implant at chronic time points. The biocompatibility of available neural implants is primarily judged based on these two metrics. These metrics have guided various designs to reduce the tissue response, lowering both astrocytic and neuronal death and density around the implant. However, the tissue response is still triggered, and signal instability remains problematic. This leads us to believe that conventional metrics alone are insufficient in guiding implant design. Other metrics must be uncovered to complete the parameter space governing the biological tissue response to neural implants. The goal of this thesis is to create computational pipelines using signal processing, image processing, and data analysis methods to (1) better understand the interaction between the tissue and neural implant, (2) uncover variables that might affect the recording quality of the implant, and (3) potentially guide future neural implant design from the perspective of gene expression, metrics of extracellular recordings, and astrocyte morphology.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (141 p.) : ill."],"dc:identifier":["etd:52551","local:Saxena_grad.msu_0128D_21165","https://doi.org/doi:10.25335/pvex-yd61"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Electrical engineering","Neurosciences","Bioengineering"],"dc:title":["ALGORITHMS TO ASSESS THE STRUCTURAL AND FUNCTIONAL CHANGES AT THE TISSUE ELECTRODE INTERFACE THROUGH THE ANALYSIS OF GENE EXPRESSION, METRICS OF ELECTROPHYSIOLOGY, AND ASTROCYTE MORPHOLOGY"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:06Z"}