{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52599"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52599","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"INDOOR MOLD CONCENTRATIONS, PREVALENCE, AND RELATION TO BUILDING CHARACTERISTICS IN HOMES IN VERY COLD CLIMATES","abstract":"Thesis (M.S.)--Michigan State University. Civil Engineering - Master of Science, 2025","abstract_html":"Thesis (M.S.)--Michigan State University. Civil Engineering - Master of Science, 2025","abstract_has_math":false,"creators":["Conrad, Cassandra"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Cetin, Kristen","Lin, Kaisen","Anctil, Annick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T18:59:09Z","subjects":["Civil engineering"],"languages":["eng"],"rights":["Attribution 4.0 International"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52599","local:Conrad_grad.msu_0128N_21562"],"render_values":[{"text":"etd:52599","href":null,"code":true},{"text":"local:Conrad_grad.msu_0128N_21562","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/x9dy-p048","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/x9dy-p048","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52599","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Cetin, Kristen","Lin, Kaisen","Anctil, Annick"]},{"key":"dc:creator","label":"Author","values":["Conrad, Cassandra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52599","local:Conrad_grad.msu_0128N_21562","https://doi.org/doi:10.25335/x9dy-p048"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Michigan State University. Civil Engineering - Master of Science, 2025","People in the U.S. spend more than 90% of their time indoors. In extremely cold climates including Alaska (ASHRAE Climate Zone 8), homes provide essential shelter, yet these homes are often smaller, overcrowded, and not designed for the harsh cold climate that requires year-round heating. Extreme cold weather also creates potential condensation risk and thus the potential for mold growth. Previous research has found that many Alaska residents have concerns about mold growth in their homes and also has shown the prevalence of mold-induced respiratory infections and conditions particularly for children in these locations. However, it is rare for studies to quantify the concentration of mold or quantify its causes. This study utilized surface and airborne mold tests alongside in-person home assessments in 72 households in two rural coastal Alaskan communities. Results detected the potential for mold in the air of 39% of homes tested, and mold was found on at least one surface in 67% of homes tested. Nonparametric statistical tests were performed to analyze correlations between indoor mold concentrations and housing characteristics. Surface mold was more likely to be found in homes that were older, more densely occupied, were more humid, did not have Heat Recovery Ventilators (HRVs), or samples taken from windows. Airborne mold was significantly correlated with the community, indoor humidity, and room type. This study highlights the household characteristics that potentially indicate the air and surface mold growth status in homes in very cold climates.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (47 p.) : ill."]},{"key":"dc:title","label":"Title","values":["INDOOR MOLD CONCENTRATIONS, PREVALENCE, AND RELATION TO BUILDING CHARACTERISTICS IN HOMES IN VERY COLD CLIMATES"]}]}],"canonical_facts":{"dc:contributor":["Cetin, Kristen","Lin, Kaisen","Anctil, Annick"],"dc:creator":["Conrad, Cassandra"],"dc:date":["2025"],"dc:description":["Thesis (M.S.)--Michigan State University. Civil Engineering - Master of Science, 2025","People in the U.S. spend more than 90% of their time indoors. In extremely cold climates including Alaska (ASHRAE Climate Zone 8), homes provide essential shelter, yet these homes are often smaller, overcrowded, and not designed for the harsh cold climate that requires year-round heating. Extreme cold weather also creates potential condensation risk and thus the potential for mold growth. Previous research has found that many Alaska residents have concerns about mold growth in their homes and also has shown the prevalence of mold-induced respiratory infections and conditions particularly for children in these locations. However, it is rare for studies to quantify the concentration of mold or quantify its causes. This study utilized surface and airborne mold tests alongside in-person home assessments in 72 households in two rural coastal Alaskan communities. Results detected the potential for mold in the air of 39% of homes tested, and mold was found on at least one surface in 67% of homes tested. Nonparametric statistical tests were performed to analyze correlations between indoor mold concentrations and housing characteristics. Surface mold was more likely to be found in homes that were older, more densely occupied, were more humid, did not have Heat Recovery Ventilators (HRVs), or samples taken from windows. Airborne mold was significantly correlated with the community, indoor humidity, and room type. This study highlights the household characteristics that potentially indicate the air and surface mold growth status in homes in very cold climates.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (47 p.) : ill."],"dc:identifier":["etd:52599","local:Conrad_grad.msu_0128N_21562","https://doi.org/doi:10.25335/x9dy-p048"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["Attribution 4.0 International"],"dc:subject":["Civil engineering"],"dc:title":["INDOOR MOLD CONCENTRATIONS, PREVALENCE, AND RELATION TO BUILDING CHARACTERISTICS IN HOMES IN VERY COLD CLIMATES"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:09Z"}