{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52797"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52797","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Investigating New Applications of a Statistical Method to Compare Mass Spectra of Seized Drug Samples","abstract":"Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2025","abstract_html":"Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2025","abstract_has_math":false,"creators":["Rahn, Alexandra Rae"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Waddell Smith, Ruth","McGuffin, Victoria","Holt, Thomas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T18:59:28Z","subjects":["Forensic sciences","Chemistry","Statistics"],"languages":["eng"],"rights":["Attribution 4.0 International"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52797","local:Rahn_grad.msu_0128N_21803"],"render_values":[{"text":"etd:52797","href":null,"code":true},{"text":"local:Rahn_grad.msu_0128N_21803","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/g47e-0m15","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/g47e-0m15","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52797","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Waddell Smith, Ruth","McGuffin, Victoria","Holt, Thomas"]},{"key":"dc:creator","label":"Author","values":["Rahn, Alexandra Rae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Forensic sciences","Chemistry","Statistics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52797","local:Rahn_grad.msu_0128N_21803","https://doi.org/doi:10.25335/g47e-0m15"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2025","The definitive identification of newly emerging controlled substances, including variousfentanyl analogs and synthetic opioids, can be challenging when comparing highly similar electron-ionization (EI) mass spectra. Previous research has demonstrated the ability of the unequal variance t-test to statistically distinguish or associate mass spectra of various seized drug samples. The unequal variance t-test method identifies discriminating ions between two mass spectra, with previous research demonstrating the reliability of these ions for discrimination. In this work, the unequal variance t-test method used to statistically compare EI mass spectra is further evaluated in two ways. First, the effect of mass spectral selection on the association and discrimination of fentanyl isomers is evaluated. And second, a new application of the method as a tool to select variables for the development of multivariate classification models is investigated. In this first part of this work, positional isomers of fentanyl analogs were analyzed by gas chromatography-mass spectrometry (GC-MS). Mass spectra collected at the chromatographic peak apex and averaged across the peak width at half height were statistically compared using the unequal variance t-test method. The number and identity of reliable discriminating ions as well as the ability to associate and discriminate the isomers was consistent regardless of mass spectral selection. In the second part of this work, the unequal variance t-test method was evaluated as a variable selection tool prior to development of linear discriminant analysis (LDA) models for classification. Classification success of structural and positional isomers of fentanyl analogs was equivalent or improved upon using the unequal variance t-test method for variable selection compared to the more traditional method using principal component analysis (PCA).","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (109 p.) : ill."]},{"key":"dc:title","label":"Title","values":["Investigating New Applications of a Statistical Method to Compare Mass Spectra of Seized Drug Samples"]}]}],"canonical_facts":{"dc:contributor":["Waddell Smith, Ruth","McGuffin, Victoria","Holt, Thomas"],"dc:creator":["Rahn, Alexandra Rae"],"dc:date":["2025"],"dc:description":["Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2025","The definitive identification of newly emerging controlled substances, including variousfentanyl analogs and synthetic opioids, can be challenging when comparing highly similar electron-ionization (EI) mass spectra. Previous research has demonstrated the ability of the unequal variance t-test to statistically distinguish or associate mass spectra of various seized drug samples. The unequal variance t-test method identifies discriminating ions between two mass spectra, with previous research demonstrating the reliability of these ions for discrimination. In this work, the unequal variance t-test method used to statistically compare EI mass spectra is further evaluated in two ways. First, the effect of mass spectral selection on the association and discrimination of fentanyl isomers is evaluated. And second, a new application of the method as a tool to select variables for the development of multivariate classification models is investigated. In this first part of this work, positional isomers of fentanyl analogs were analyzed by gas chromatography-mass spectrometry (GC-MS). Mass spectra collected at the chromatographic peak apex and averaged across the peak width at half height were statistically compared using the unequal variance t-test method. The number and identity of reliable discriminating ions as well as the ability to associate and discriminate the isomers was consistent regardless of mass spectral selection. In the second part of this work, the unequal variance t-test method was evaluated as a variable selection tool prior to development of linear discriminant analysis (LDA) models for classification. Classification success of structural and positional isomers of fentanyl analogs was equivalent or improved upon using the unequal variance t-test method for variable selection compared to the more traditional method using principal component analysis (PCA).","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (109 p.) : ill."],"dc:identifier":["etd:52797","local:Rahn_grad.msu_0128N_21803","https://doi.org/doi:10.25335/g47e-0m15"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["Attribution 4.0 International"],"dc:subject":["Forensic sciences","Chemistry","Statistics"],"dc:title":["Investigating New Applications of a Statistical Method to Compare Mass Spectra of Seized Drug Samples"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:28Z"}