{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52876"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52876","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"ELECTROCHEMICAL ANALYSIS OF DRUGS AND DISEASE BIOMARKERS USING INKJET-PRINTED CARBON AND BORON-DOPED DIAMOND ELECTRODES","abstract":"Thesis (Ph.D.)--Michigan State University. Chemistry - Doctor of Philosophy, 2025","abstract_html":"Thesis (Ph.D.)--Michigan State University. Chemistry - Doctor of Philosophy, 2025","abstract_has_math":false,"creators":["Jacobs, Aaron Isaac"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Swain, Greg","Sun, Liangliang","Blanchard, Gary","Abuelo Sebio, Angel"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T18:59:31Z","subjects":["Analytical chemistry","Chemistry"],"languages":["eng"],"rights":["Attribution 4.0 International"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52876","local:Jacobs_grad.msu_0128D_21866"],"render_values":[{"text":"etd:52876","href":null,"code":true},{"text":"local:Jacobs_grad.msu_0128D_21866","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/2qmj-xt42","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/2qmj-xt42","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52876","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Swain, Greg","Sun, Liangliang","Blanchard, Gary","Abuelo Sebio, Angel"]},{"key":"dc:creator","label":"Author","values":["Jacobs, Aaron Isaac"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analytical chemistry","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52876","local:Jacobs_grad.msu_0128D_21866","https://doi.org/doi:10.25335/2qmj-xt42"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Chemistry - Doctor of Philosophy, 2025","Detection of drugs and disease biomarkers is increasingly relevant in modern medicine. Electrochemical sensors are incredibly useful for this purpose. They offer fast, sensitive responses with good detection figures. Inkjet-printed carbon and boron-doped diamond electrodes are two electrode formats used for such measurements. Inkjet-printed carbon electrodes can be made at scale, are low waste, and are customizable. Boron-doped diamond is a p-type semiconductor material with superlative electrochemical properties, including low, stable background current, chemical and mechanical stability, and low adsorption of analytes. These features make these two electrodes attractive choices for drug and disease biomarker detection.Exhaled breath condensate is a biospecimen rich with biochemical information about the airway lining fluid. Its composition reflects the health status of the airways and has potential as a specimen for disease diagnosis and monitoring. In this work, the pH and electrochemical response of exhaled breath condensate collected from pre-weaned dairy calves is measured using polyaniline-modified or unmodified inkjet-printed nanocarbon electrodes. Breath condensate from a cohort of healthy calves and calves diagnosed with bovine respiratory disease were tested to determine if health status affects the exhaled breath condensate composition. The measurement of calf EBC pH was heavily affected by environmental variables that need to be accounted for if the biospecimen is to be used to evaluate bovine respiratory disease. For the first time, electrochemically-active species were discovered in the bovine breath. Preliminary results indicate iodide present in the bovine exhaled breath condensate is partially responsible for the measured voltammetric response. Boron-doped diamond electrodes were used to measure the drugs diclofenac, carbamazepine, and cisplatin using square wave voltammetry or flow injection analysis with amperometric detection. The detection limits for these assays were in the nanomolar range. The current vs. concentration response was linear over the two to three orders of magnitude measured. The assay was tested by spiking cisplatin into an authentic pooled human urine specimen. This presented analytical challenges since there are numerous oxidizable species that interfered with cisplatin detection. Ion-exclusion chromatographic separation was used to add selectivity to the method. This is the first report of this separation mode used for cisplatin. The boron-doped diamond was then used as a sensing element in a magnetic microbead-based electrochemical immunoassay to detect cardiac stress and lung cancer biomarkers, BNP and PD-L1. The assay successfully measured single concentrations of each biomarker. This is the first report of boron-doped diamond used to measure these analytes in an immunosensor format. Future development is required to validate if these biomarkers are clinically useful in exhaled breath condensate specimens collected from lung cancer patients. The results presented herein demonstrate the value of inkjet-printed nanocarbon and boron-doped diamond electrodes as electrochemical sensors with an emphasis on urine and exhaled breath condensate as biospecimens.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (215 p.) : ill."]},{"key":"dc:title","label":"Title","values":["ELECTROCHEMICAL ANALYSIS OF DRUGS AND DISEASE BIOMARKERS USING INKJET-PRINTED CARBON AND BORON-DOPED DIAMOND ELECTRODES"]}]}],"canonical_facts":{"dc:contributor":["Swain, Greg","Sun, Liangliang","Blanchard, Gary","Abuelo Sebio, Angel"],"dc:creator":["Jacobs, Aaron Isaac"],"dc:date":["2025"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Chemistry - Doctor of Philosophy, 2025","Detection of drugs and disease biomarkers is increasingly relevant in modern medicine. Electrochemical sensors are incredibly useful for this purpose. They offer fast, sensitive responses with good detection figures. Inkjet-printed carbon and boron-doped diamond electrodes are two electrode formats used for such measurements. Inkjet-printed carbon electrodes can be made at scale, are low waste, and are customizable. Boron-doped diamond is a p-type semiconductor material with superlative electrochemical properties, including low, stable background current, chemical and mechanical stability, and low adsorption of analytes. These features make these two electrodes attractive choices for drug and disease biomarker detection.Exhaled breath condensate is a biospecimen rich with biochemical information about the airway lining fluid. Its composition reflects the health status of the airways and has potential as a specimen for disease diagnosis and monitoring. In this work, the pH and electrochemical response of exhaled breath condensate collected from pre-weaned dairy calves is measured using polyaniline-modified or unmodified inkjet-printed nanocarbon electrodes. Breath condensate from a cohort of healthy calves and calves diagnosed with bovine respiratory disease were tested to determine if health status affects the exhaled breath condensate composition. The measurement of calf EBC pH was heavily affected by environmental variables that need to be accounted for if the biospecimen is to be used to evaluate bovine respiratory disease. For the first time, electrochemically-active species were discovered in the bovine breath. Preliminary results indicate iodide present in the bovine exhaled breath condensate is partially responsible for the measured voltammetric response. Boron-doped diamond electrodes were used to measure the drugs diclofenac, carbamazepine, and cisplatin using square wave voltammetry or flow injection analysis with amperometric detection. The detection limits for these assays were in the nanomolar range. The current vs. concentration response was linear over the two to three orders of magnitude measured. The assay was tested by spiking cisplatin into an authentic pooled human urine specimen. This presented analytical challenges since there are numerous oxidizable species that interfered with cisplatin detection. Ion-exclusion chromatographic separation was used to add selectivity to the method. This is the first report of this separation mode used for cisplatin. The boron-doped diamond was then used as a sensing element in a magnetic microbead-based electrochemical immunoassay to detect cardiac stress and lung cancer biomarkers, BNP and PD-L1. The assay successfully measured single concentrations of each biomarker. This is the first report of boron-doped diamond used to measure these analytes in an immunosensor format. Future development is required to validate if these biomarkers are clinically useful in exhaled breath condensate specimens collected from lung cancer patients. The results presented herein demonstrate the value of inkjet-printed nanocarbon and boron-doped diamond electrodes as electrochemical sensors with an emphasis on urine and exhaled breath condensate as biospecimens.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (215 p.) : ill."],"dc:identifier":["etd:52876","local:Jacobs_grad.msu_0128D_21866","https://doi.org/doi:10.25335/2qmj-xt42"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["Attribution 4.0 International"],"dc:subject":["Analytical chemistry","Chemistry"],"dc:title":["ELECTROCHEMICAL ANALYSIS OF DRUGS AND DISEASE BIOMARKERS USING INKJET-PRINTED CARBON AND BORON-DOPED DIAMOND ELECTRODES"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:31Z"}