{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52933"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52933","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"QUANTIFYING SECONDARY ENERGY IMPACTS OF BUILDING ENERGY EFFICIENCY IMPROVEMENTS IN INDUSTRIAL FACILITIES THROUGH ENERGY MODELING","abstract":"Thesis (M.S.)--Michigan State University. Environmental Engineering - Master of Science, 2026","abstract_html":"Thesis (M.S.)--Michigan State University. Environmental Engineering - Master of Science, 2026","abstract_has_math":false,"creators":["Thompson, Julianna Jean"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Cetin, Kristen","Lin, Kaisen","Xagoraraki, Irene"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:31Z","subjects":["Environmental engineering","Civil engineering","Industrial engineering"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52933","local:Thompson_grad.msu_0128N_21938"],"render_values":[{"text":"etd:52933","href":null,"code":true},{"text":"local:Thompson_grad.msu_0128N_21938","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/dt0a-0222","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/dt0a-0222","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52933","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Cetin, Kristen","Lin, Kaisen","Xagoraraki, Irene"]},{"key":"dc:creator","label":"Author","values":["Thompson, Julianna Jean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Environmental engineering","Civil engineering","Industrial engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52933","local:Thompson_grad.msu_0128N_21938","https://doi.org/doi:10.25335/dt0a-0222"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Michigan State University. Environmental Engineering - Master of Science, 2026","During energy assessments of industrial buildings, the estimated energy savings of recommended improvements are typically calculated based only on primary impacts. However, reduction in energy consumption from internal loads also has secondary impacts on the heating and cooling systems within these facilities. There is a need for quantification of these interactions, particularly for industrial buildings which have been less studied and are less understood. Among the most commonly recommended energy efficiency measures for industrial facilities are improving the efficiency of lighting and compressed air systems, thus interaction between these systems and HVAC are of interest. Additionally, there is only a limited understanding of what characterizes a “typical” industrial building in the U.S, particularly relative to more significantly studied commercial buildings. This research first develops and validates a typical building energy model of a manufacturing facility in the U.S. using OpenStudio and EnergyPlus. Then, parametric analysis was used to quantify the secondary impact of energy efficiency improvements to lighting and compressed air systems on HVAC operations across multiple climate zones. These results are then compared to estimates considering only primary energy savings. For lighting and compressed air efficiency upgrades, findings indicate that primary energy savings underestimate electricity savings due to cooling load interaction (27-48% and 9-16%, respectively) while also not reporting increased energy needs of heating systems (1-44% and 0-13%, respectively). Additionally, net energy impacts identify the threshold when additional natural gas use surpasses additional electricity savings. Results of this research indicate that secondary energy impacts due to interaction should be considered in energy assessment reporting to improve accuracy in energy savings estimates.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (42 p.) : ill."]},{"key":"dc:title","label":"Title","values":["QUANTIFYING SECONDARY ENERGY IMPACTS OF BUILDING ENERGY EFFICIENCY IMPROVEMENTS IN INDUSTRIAL FACILITIES THROUGH ENERGY MODELING"]}]}],"canonical_facts":{"dc:contributor":["Cetin, Kristen","Lin, Kaisen","Xagoraraki, Irene"],"dc:creator":["Thompson, Julianna Jean"],"dc:date":["2026"],"dc:description":["Thesis (M.S.)--Michigan State University. Environmental Engineering - Master of Science, 2026","During energy assessments of industrial buildings, the estimated energy savings of recommended improvements are typically calculated based only on primary impacts. However, reduction in energy consumption from internal loads also has secondary impacts on the heating and cooling systems within these facilities. There is a need for quantification of these interactions, particularly for industrial buildings which have been less studied and are less understood. Among the most commonly recommended energy efficiency measures for industrial facilities are improving the efficiency of lighting and compressed air systems, thus interaction between these systems and HVAC are of interest. Additionally, there is only a limited understanding of what characterizes a “typical” industrial building in the U.S, particularly relative to more significantly studied commercial buildings. This research first develops and validates a typical building energy model of a manufacturing facility in the U.S. using OpenStudio and EnergyPlus. Then, parametric analysis was used to quantify the secondary impact of energy efficiency improvements to lighting and compressed air systems on HVAC operations across multiple climate zones. These results are then compared to estimates considering only primary energy savings. For lighting and compressed air efficiency upgrades, findings indicate that primary energy savings underestimate electricity savings due to cooling load interaction (27-48% and 9-16%, respectively) while also not reporting increased energy needs of heating systems (1-44% and 0-13%, respectively). Additionally, net energy impacts identify the threshold when additional natural gas use surpasses additional electricity savings. Results of this research indicate that secondary energy impacts due to interaction should be considered in energy assessment reporting to improve accuracy in energy savings estimates.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (42 p.) : ill."],"dc:identifier":["etd:52933","local:Thompson_grad.msu_0128N_21938","https://doi.org/doi:10.25335/dt0a-0222"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Environmental engineering","Civil engineering","Industrial engineering"],"dc:title":["QUANTIFYING SECONDARY ENERGY IMPACTS OF BUILDING ENERGY EFFICIENCY IMPROVEMENTS IN INDUSTRIAL FACILITIES THROUGH ENERGY MODELING"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:31Z"}