{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52947"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52947","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"DEVELOPING A METHAMPHETAMINE QUANTIFICATION MODEL USING ATR-FTIR SPECTROSCOPY AND PARTIAL-LEAST-SQUARES REGRESSION FOR MULTI-INSTRUMENT APPLICATION","abstract":"Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2026","abstract_html":"Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2026","abstract_has_math":false,"creators":["Simonis, Emily Dolores"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Smith, Ruth","McGaw, Elizabeth","Holt, Thomas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:34Z","subjects":["Chemistry","Forensic sciences"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52947","local:Simonis_grad.msu_0128N_21958"],"render_values":[{"text":"etd:52947","href":null,"code":true},{"text":"local:Simonis_grad.msu_0128N_21958","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/44ee-nf66","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/44ee-nf66","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52947","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Smith, Ruth","McGaw, Elizabeth","Holt, Thomas"]},{"key":"dc:creator","label":"Author","values":["Simonis, Emily Dolores"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry","Forensic sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52947","local:Simonis_grad.msu_0128N_21958","https://doi.org/doi:10.25335/44ee-nf66"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2026","Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy requires no sample preparation and takes only minutes to analyze a sample making it a useful technique for seized drug analysis. This work describes the development and evaluation of multivariate regression models to predict concentration of seized drugs in mixed samples based on IR spectra. Binary mixtures of methamphetamine and caffeine were prepared, with the methamphetamine concentration ranging from 0 - 100% in 10% increments by weight. These mixtures, which constituted the training set for model development, were analyzed in replicate multiple times over several months on two different instruments (Instrument 1 and 2). Additional binary mixtures were prepared in a similar manner to constitute a test set for model evaluation. Another analyst prepared blind mixtures that could contain methamphetamine, caffeine, diphenhydramine, and/or amphetamine. All spectra were baseline corrected and normalized using the standard normal variate method. Partial-least-squares regression (PLSR) was then applied to the training set spectra collected on each instrument to develop models to predict methamphetamine content in the test set samples. Models using the full spectra, truncated spectra, and selected peaks were created and evaluated for the optimal model design. Based on the standard error validation (SEV) and comparison of the root mean squared error of prediction (RMSEP) values of the test set samples, the full spectrum model was selected, SEV for instrument 1 and 2 was 3.82 and 4.44 respectively. For Instrument 1, the RMSEP for the test set ranged from 1.31% to 3.56%, with an overall RMSEP of 2.36%. For Instrument 2, the RMSEP for the test set ranged from 1.38% to 5.85%, with an overall RMSEP of 4.12%. Diphenhydramine containing test sets were not able to be accurately predicted. Possible errors were investigated including sample volume when collecting the spectra and saturation of the diphenhydramine. The performance of each model in predicting methamphetamine concentration in samples analyzed on a different instrument was then evaluated. Using the model developed on Instrument 1, the RMSEP in predicting test set samples analyzed on Instrument 2 was 4.96%. Similarly, using the model developed on Instrument 2, the RMSEP in predicting test set samples analyzed on Instrument 1 was 3.93%. This comparable performance on different instruments shows potential for broader applications. Regression models for common mixtures could be developed and shared among laboratories, allowing quantification using spectra collected on different instruments.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (87 p.) : ill."]},{"key":"dc:title","label":"Title","values":["DEVELOPING A METHAMPHETAMINE QUANTIFICATION MODEL USING ATR-FTIR SPECTROSCOPY AND PARTIAL-LEAST-SQUARES REGRESSION FOR MULTI-INSTRUMENT APPLICATION"]}]}],"canonical_facts":{"dc:contributor":["Smith, Ruth","McGaw, Elizabeth","Holt, Thomas"],"dc:creator":["Simonis, Emily Dolores"],"dc:date":["2026"],"dc:description":["Thesis (M.S.)--Michigan State University. Forensic Science - Master of Science, 2026","Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy requires no sample preparation and takes only minutes to analyze a sample making it a useful technique for seized drug analysis. This work describes the development and evaluation of multivariate regression models to predict concentration of seized drugs in mixed samples based on IR spectra. Binary mixtures of methamphetamine and caffeine were prepared, with the methamphetamine concentration ranging from 0 - 100% in 10% increments by weight. These mixtures, which constituted the training set for model development, were analyzed in replicate multiple times over several months on two different instruments (Instrument 1 and 2). Additional binary mixtures were prepared in a similar manner to constitute a test set for model evaluation. Another analyst prepared blind mixtures that could contain methamphetamine, caffeine, diphenhydramine, and/or amphetamine. All spectra were baseline corrected and normalized using the standard normal variate method. Partial-least-squares regression (PLSR) was then applied to the training set spectra collected on each instrument to develop models to predict methamphetamine content in the test set samples. Models using the full spectra, truncated spectra, and selected peaks were created and evaluated for the optimal model design. Based on the standard error validation (SEV) and comparison of the root mean squared error of prediction (RMSEP) values of the test set samples, the full spectrum model was selected, SEV for instrument 1 and 2 was 3.82 and 4.44 respectively. For Instrument 1, the RMSEP for the test set ranged from 1.31% to 3.56%, with an overall RMSEP of 2.36%. For Instrument 2, the RMSEP for the test set ranged from 1.38% to 5.85%, with an overall RMSEP of 4.12%. Diphenhydramine containing test sets were not able to be accurately predicted. Possible errors were investigated including sample volume when collecting the spectra and saturation of the diphenhydramine. The performance of each model in predicting methamphetamine concentration in samples analyzed on a different instrument was then evaluated. Using the model developed on Instrument 1, the RMSEP in predicting test set samples analyzed on Instrument 2 was 4.96%. Similarly, using the model developed on Instrument 2, the RMSEP in predicting test set samples analyzed on Instrument 1 was 3.93%. This comparable performance on different instruments shows potential for broader applications. Regression models for common mixtures could be developed and shared among laboratories, allowing quantification using spectra collected on different instruments.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (87 p.) : ill."],"dc:identifier":["etd:52947","local:Simonis_grad.msu_0128N_21958","https://doi.org/doi:10.25335/44ee-nf66"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Chemistry","Forensic sciences"],"dc:title":["DEVELOPING A METHAMPHETAMINE QUANTIFICATION MODEL USING ATR-FTIR SPECTROSCOPY AND PARTIAL-LEAST-SQUARES REGRESSION FOR MULTI-INSTRUMENT APPLICATION"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:34Z"}