{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_52972"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_52972","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Design and Fabrication of Microfluidic Devices for Personal Airborne Particulate Matter Monitoring","abstract":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_html":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_has_math":false,"creators":["Goderis, Derek"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mason, Andrew J.","Sepulveda, Nelson","Yazdi, Navid","Hickey, David P."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:34Z","subjects":["Engineering"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52972","local:Goderis_grad.msu_0128D_21937"],"render_values":[{"text":"etd:52972","href":null,"code":true},{"text":"local:Goderis_grad.msu_0128D_21937","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/kvz5-4h58","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/kvz5-4h58","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_52972","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mason, Andrew J.","Sepulveda, Nelson","Yazdi, Navid","Hickey, David P."]},{"key":"dc:creator","label":"Author","values":["Goderis, Derek"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:52972","local:Goderis_grad.msu_0128D_21937","https://doi.org/doi:10.25335/kvz5-4h58"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Exposure to airborne particulate matter (PM) is a leading global environmental health risk, contributing to millions of premature deaths each year. PM has been strongly linked to adverse respiratory, cardiovascular, and systemic health effects. Progress in mitigating these impacts has been limited in part by the inability to accurately characterize and quantify individual exposure in real time. Most existing PM monitoring technologies rely on stationary sampling and offline laboratory analysis, preventing real-time feedback and limiting the ability to obtain size-resolved, chemically specific exposure data across diverse microenvironments and personal activity patterns.This dissertation develops a wearable, portable system for continuous PM exposure monitoring using microfluidic and microelectronic fabrication technologies. Through the combined use of MEMS microfabrication, additive manufacturing, and microfluidic design, miniaturized devices were developed to capture airborne PM, separate it into size fractions, and prepare it for downstream chemical analysis. A 3D-printed sharp-cut micro-cyclone is used for aerosol preconditioning and size-selective separation. Two microfluidic architectures enable continuous aerosol-to-liquid capture, facilitating integration with lab-on-chip analytical platforms. Additional work on continuous-flow, phase-separated aerosol impactors further enhances capture efficiency and supports cascaded, size-resolved particle collection. Furthermore, analytical electrochemical detection methods are demonstrated for the chemical detection and classification of particulate matter components and associated human biomarkers.The contributions of this work are as follows: (1) the development and validation of miniaturized devices for real-time PM capture and size fractionation; (2) the establishment of methods for downstream chemical analysis of health-relevant PM components, including trace metals and elemental carbon; and (3) the demonstration of device performance in real-world environments to characterize the spatial and temporal variability of personal PM exposure. Together, these contributions provide a framework for wearable, real-time PM monitoring capable of high-resolution assessment of individual exposures, laying the groundwork for future environmental health studies and personalized exposure interventions.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (223 p.) : ill."]},{"key":"dc:title","label":"Title","values":["Design and Fabrication of Microfluidic Devices for Personal Airborne Particulate Matter Monitoring"]}]}],"canonical_facts":{"dc:contributor":["Mason, Andrew J.","Sepulveda, Nelson","Yazdi, Navid","Hickey, David P."],"dc:creator":["Goderis, Derek"],"dc:date":["2026"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Exposure to airborne particulate matter (PM) is a leading global environmental health risk, contributing to millions of premature deaths each year. PM has been strongly linked to adverse respiratory, cardiovascular, and systemic health effects. Progress in mitigating these impacts has been limited in part by the inability to accurately characterize and quantify individual exposure in real time. Most existing PM monitoring technologies rely on stationary sampling and offline laboratory analysis, preventing real-time feedback and limiting the ability to obtain size-resolved, chemically specific exposure data across diverse microenvironments and personal activity patterns.This dissertation develops a wearable, portable system for continuous PM exposure monitoring using microfluidic and microelectronic fabrication technologies. Through the combined use of MEMS microfabrication, additive manufacturing, and microfluidic design, miniaturized devices were developed to capture airborne PM, separate it into size fractions, and prepare it for downstream chemical analysis. A 3D-printed sharp-cut micro-cyclone is used for aerosol preconditioning and size-selective separation. Two microfluidic architectures enable continuous aerosol-to-liquid capture, facilitating integration with lab-on-chip analytical platforms. Additional work on continuous-flow, phase-separated aerosol impactors further enhances capture efficiency and supports cascaded, size-resolved particle collection. Furthermore, analytical electrochemical detection methods are demonstrated for the chemical detection and classification of particulate matter components and associated human biomarkers.The contributions of this work are as follows: (1) the development and validation of miniaturized devices for real-time PM capture and size fractionation; (2) the establishment of methods for downstream chemical analysis of health-relevant PM components, including trace metals and elemental carbon; and (3) the demonstration of device performance in real-world environments to characterize the spatial and temporal variability of personal PM exposure. Together, these contributions provide a framework for wearable, real-time PM monitoring capable of high-resolution assessment of individual exposures, laying the groundwork for future environmental health studies and personalized exposure interventions.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (223 p.) : ill."],"dc:identifier":["etd:52972","local:Goderis_grad.msu_0128D_21937","https://doi.org/doi:10.25335/kvz5-4h58"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Engineering"],"dc:title":["Design and Fabrication of Microfluidic Devices for Personal Airborne Particulate Matter Monitoring"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:34Z"}