{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_53100"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_53100","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"ASSESSING HEAD INJURY RISK AND BLAST-INDUCED OVERPRESSURE THROUGH FLEXIBLE, SELF-POWERED FERRO-ELECTRET NANO-GENERATOR SENSORS","abstract":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_html":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_has_math":false,"creators":["Morales-Torres, Gerardo L."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sepúlveda, Nelson","Mejía, Ricardo","Chakrapani, Sunil K","Srivastava, Vaibhav"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:37Z","subjects":["Electrical engineering"],"languages":["eng"],"rights":["Attribution 4.0 International"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53100","local:MoralesTorres_grad.msu_0128D_22110"],"render_values":[{"text":"etd:53100","href":null,"code":true},{"text":"local:MoralesTorres_grad.msu_0128D_22110","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/tmre-8r22","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/tmre-8r22","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_53100","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sepúlveda, Nelson","Mejía, Ricardo","Chakrapani, Sunil K","Srivastava, Vaibhav"]},{"key":"dc:creator","label":"Author","values":["Morales-Torres, Gerardo L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53100","local:MoralesTorres_grad.msu_0128D_22110","https://doi.org/doi:10.25335/tmre-8r22"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Head impacts remain a significant concern in athletic and automotive environments, where accurate monitoring of dynamic mechanical loading is essential for assessing traumatic brain injury (TBI) and evaluating protective systems. Similarly, blast-induced exposures present critical challenges in military and defense environments, requiring precise characterization of high-rate overpressure events. Conventional sensing systems rely on rigid, externally powered architectures that can limit wearability, conformal integration, and deployment flexibility. Flexible piezoelectric-like sensors provide a self-powered alternative by converting mechanical deformation into measurable electrical signals during dynamic loading. This dissertation presents the development and evaluation of a flexible ferro-electret nanogenerator (FENG) sensing platform for monitoring dynamic mechanical events across both head impact biomechanics and explosive blast environments. A fully wireless neck-mounted sensing system was implemented and evaluated under direct head impacts using a Hybrid III head–neck surrogate. The study extended prior whiplash-only investigations to perpendicular and oblique impact scenarios. Results showed that the first derivative of the FENG voltage aligned with angular velocity measurements from internal accelerometers, and that impacts from most directions could be detected, confirming directional sensitivity while identifying orientation-dependent magnitude variations. These findings demonstrated that a self-powered, flexible sensing architecture can function as a wearable head monitoring system with reduced reliance on rigid instrumentation.The sensing framework was further advanced through integration with supervised machine learning models to predict peak angular velocity and acceleration directly from the FENG signal. A dataset of 150 controlled whiplash-like events was used to train and evaluate multiple regression models, including Multi-Layer Perceptron (MLP), Support Vector Machine (SVM), Random Forest, XGBoost, and Gradient Boosting Machine (GBM). Ensemble-based methods achieved mean absolute percentage errors below 1% for velocity prediction with similarly low errors for acceleration estimation. A structured methodology was also established to estimate injury severity metrics from FENG-derived outputs, enabling data-driven assessment of head impact severity using flexible electromechanical sensing.Beyond biomechanics, the FENG platform was evaluated under controlled explosive blast loading. The sensor repeatedly captured transient blast waveforms, with voltage responses scaling consistently and near-linearly with blast intensity across test levels. Time integration of the FENG output exhibited strong correspondence with reference overpressure measurements, demonstrating that blast overpressure characteristics can be quantitatively mapped through flexible electromechanical sensing (?2 = 0.971). Stable performance under varied mounting orientations furtherhighlighted its robustness in high-rate dynamic environments.Collectively, this work establishes flexible, self-powered FENG technology as a versatile sensing platform capable of detecting directional head impacts, predicting head kinematics, estimating injury severity, and capturing blast-induced overpressure behavior across distinct high-rate loading regimes while maintaining mechanical flexibility and reduced system complexity compared to conventional rigid sensing systems.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (113 p.) : ill."]},{"key":"dc:title","label":"Title","values":["ASSESSING HEAD INJURY RISK AND BLAST-INDUCED OVERPRESSURE THROUGH FLEXIBLE, SELF-POWERED FERRO-ELECTRET NANO-GENERATOR SENSORS"]}]}],"canonical_facts":{"dc:contributor":["Sepúlveda, Nelson","Mejía, Ricardo","Chakrapani, Sunil K","Srivastava, Vaibhav"],"dc:creator":["Morales-Torres, Gerardo L."],"dc:date":["2026"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Head impacts remain a significant concern in athletic and automotive environments, where accurate monitoring of dynamic mechanical loading is essential for assessing traumatic brain injury (TBI) and evaluating protective systems. Similarly, blast-induced exposures present critical challenges in military and defense environments, requiring precise characterization of high-rate overpressure events. Conventional sensing systems rely on rigid, externally powered architectures that can limit wearability, conformal integration, and deployment flexibility. Flexible piezoelectric-like sensors provide a self-powered alternative by converting mechanical deformation into measurable electrical signals during dynamic loading. This dissertation presents the development and evaluation of a flexible ferro-electret nanogenerator (FENG) sensing platform for monitoring dynamic mechanical events across both head impact biomechanics and explosive blast environments. A fully wireless neck-mounted sensing system was implemented and evaluated under direct head impacts using a Hybrid III head–neck surrogate. The study extended prior whiplash-only investigations to perpendicular and oblique impact scenarios. Results showed that the first derivative of the FENG voltage aligned with angular velocity measurements from internal accelerometers, and that impacts from most directions could be detected, confirming directional sensitivity while identifying orientation-dependent magnitude variations. These findings demonstrated that a self-powered, flexible sensing architecture can function as a wearable head monitoring system with reduced reliance on rigid instrumentation.The sensing framework was further advanced through integration with supervised machine learning models to predict peak angular velocity and acceleration directly from the FENG signal. A dataset of 150 controlled whiplash-like events was used to train and evaluate multiple regression models, including Multi-Layer Perceptron (MLP), Support Vector Machine (SVM), Random Forest, XGBoost, and Gradient Boosting Machine (GBM). Ensemble-based methods achieved mean absolute percentage errors below 1% for velocity prediction with similarly low errors for acceleration estimation. A structured methodology was also established to estimate injury severity metrics from FENG-derived outputs, enabling data-driven assessment of head impact severity using flexible electromechanical sensing.Beyond biomechanics, the FENG platform was evaluated under controlled explosive blast loading. The sensor repeatedly captured transient blast waveforms, with voltage responses scaling consistently and near-linearly with blast intensity across test levels. Time integration of the FENG output exhibited strong correspondence with reference overpressure measurements, demonstrating that blast overpressure characteristics can be quantitatively mapped through flexible electromechanical sensing (?2 = 0.971). Stable performance under varied mounting orientations furtherhighlighted its robustness in high-rate dynamic environments.Collectively, this work establishes flexible, self-powered FENG technology as a versatile sensing platform capable of detecting directional head impacts, predicting head kinematics, estimating injury severity, and capturing blast-induced overpressure behavior across distinct high-rate loading regimes while maintaining mechanical flexibility and reduced system complexity compared to conventional rigid sensing systems.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (113 p.) : ill."],"dc:identifier":["etd:53100","local:MoralesTorres_grad.msu_0128D_22110","https://doi.org/doi:10.25335/tmre-8r22"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["Attribution 4.0 International"],"dc:subject":["Electrical engineering"],"dc:title":["ASSESSING HEAD INJURY RISK AND BLAST-INDUCED OVERPRESSURE THROUGH FLEXIBLE, SELF-POWERED FERRO-ELECTRET NANO-GENERATOR SENSORS"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:37Z"}