{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_53167"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_53167","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"MAGNETIC-FACILITATED ELECTRO-COAGULATION AND ELECTRODIALYSIS FOR DECENTRALIZED BLACKWATER TREATMENT, AMMONIA RECOVERY, AND WATER RECLAMATION","abstract":"Thesis (M.S.)--Michigan State University. Biosystems Engineering - Master of Science, 2026","abstract_html":"Thesis (M.S.)--Michigan State University. Biosystems Engineering - Master of Science, 2026","abstract_has_math":false,"creators":["Monson, Carter b"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Liao, Wei","Liu, Yan","Dusenbury, James"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:41Z","subjects":["Water resource management","Energy","Power resources"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53167","local:Monson_grad.msu_0128N_22202"],"render_values":[{"text":"etd:53167","href":null,"code":true},{"text":"local:Monson_grad.msu_0128N_22202","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/g5e3-7284","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/g5e3-7284","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_53167","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Liao, Wei","Liu, Yan","Dusenbury, James"]},{"key":"dc:creator","label":"Author","values":["Monson, Carter b"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water resource management","Energy","Power resources"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53167","local:Monson_grad.msu_0128N_22202","https://doi.org/doi:10.25335/g5e3-7284"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Michigan State University. Biosystems Engineering - Master of Science, 2026","Decentralized wastewater treatment systems have gained increased intertest for addressing resource limitations, infrastructure constraints, and highly variable waste streams in non-sewered and transient environments. This study presents an integrated electro-mechanical system for blackwater treatment, ammonia recovery, and water reclamation. Combining magnetic-enhanced electrocoagulation (EC), electrodialysis (ED), and vapor flush stripping with Stirling cryogenic condensation. This system is designed to retain, concentrate, and recover ammonia as a value-added product while simultaneously treating blackwater. Magnetic-enhanced EC improved treatment performance, achieving 67.1 ± 8.0% COD removal compared to 41.6 ± 13.9% for conventional EC, while removing >90% turbidity and phosphorus and retaining dissolved ammonia. Post-EC conditioning via ozonation, pH adjustment, and filtration enhanced effluent clarity and reduced fouling potential for ED. Electrodialysis effectively concentrated ammonium to 10.5 g/L, enabling efficient downstream recovery. The theoretical integrated vapor flush–cryogenic system achieved 95% ammonia recovery from a 10 g/L feed, producing 0.95 kg/day of liquid ammonia. The vapor phase reached an ammonia mole fraction of ~0.22, demonstrating effective enrichment. Energy analysis indicated a thermal demand of 9.1 MJ/day (2.66 kWh/kg NH3) and low electrical consumption of 2.24 kWh/day (2.36 kWh/kg NH3). Recoverable waste heat (~19.2 MJ/day) exceeded thermal requirements, enabling potential full heat integration. Overall, the system provides a modular, energy-efficient platform for decentralized treatment and circular resource recovery.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (116 p.) : ill."]},{"key":"dc:title","label":"Title","values":["MAGNETIC-FACILITATED ELECTRO-COAGULATION AND ELECTRODIALYSIS FOR DECENTRALIZED BLACKWATER TREATMENT, AMMONIA RECOVERY, AND WATER RECLAMATION"]}]}],"canonical_facts":{"dc:contributor":["Liao, Wei","Liu, Yan","Dusenbury, James"],"dc:creator":["Monson, Carter b"],"dc:date":["2026"],"dc:description":["Thesis (M.S.)--Michigan State University. Biosystems Engineering - Master of Science, 2026","Decentralized wastewater treatment systems have gained increased intertest for addressing resource limitations, infrastructure constraints, and highly variable waste streams in non-sewered and transient environments. This study presents an integrated electro-mechanical system for blackwater treatment, ammonia recovery, and water reclamation. Combining magnetic-enhanced electrocoagulation (EC), electrodialysis (ED), and vapor flush stripping with Stirling cryogenic condensation. This system is designed to retain, concentrate, and recover ammonia as a value-added product while simultaneously treating blackwater. Magnetic-enhanced EC improved treatment performance, achieving 67.1 ± 8.0% COD removal compared to 41.6 ± 13.9% for conventional EC, while removing >90% turbidity and phosphorus and retaining dissolved ammonia. Post-EC conditioning via ozonation, pH adjustment, and filtration enhanced effluent clarity and reduced fouling potential for ED. Electrodialysis effectively concentrated ammonium to 10.5 g/L, enabling efficient downstream recovery. The theoretical integrated vapor flush–cryogenic system achieved 95% ammonia recovery from a 10 g/L feed, producing 0.95 kg/day of liquid ammonia. The vapor phase reached an ammonia mole fraction of ~0.22, demonstrating effective enrichment. Energy analysis indicated a thermal demand of 9.1 MJ/day (2.66 kWh/kg NH3) and low electrical consumption of 2.24 kWh/day (2.36 kWh/kg NH3). Recoverable waste heat (~19.2 MJ/day) exceeded thermal requirements, enabling potential full heat integration. Overall, the system provides a modular, energy-efficient platform for decentralized treatment and circular resource recovery.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (116 p.) : ill."],"dc:identifier":["etd:53167","local:Monson_grad.msu_0128N_22202","https://doi.org/doi:10.25335/g5e3-7284"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Water resource management","Energy","Power resources"],"dc:title":["MAGNETIC-FACILITATED ELECTRO-COAGULATION AND ELECTRODIALYSIS FOR DECENTRALIZED BLACKWATER TREATMENT, AMMONIA RECOVERY, AND WATER RECLAMATION"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:41Z"}