{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_53269"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_53269","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"ADVANCED FLEXIBLE AND STRETCHABLE ELECTROMAGNETIC NDE SENSORS ARRAY","abstract":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_html":"Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","abstract_has_math":false,"creators":["Peng, Lei"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Deng, Yiming","Udpa, Lalita","Udpa, Satshi","Han, Ming","Haq, Mahmoodul","Mukherjee, Saptarshi"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:44Z","subjects":["Electrical engineering","Engineering"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53269","local:Peng_grad.msu_0128D_22317"],"render_values":[{"text":"etd:53269","href":null,"code":true},{"text":"local:Peng_grad.msu_0128D_22317","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/c36a-9d51","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/c36a-9d51","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_53269","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Deng, Yiming","Udpa, Lalita","Udpa, Satshi","Han, Ming","Haq, Mahmoodul","Mukherjee, Saptarshi"]},{"key":"dc:creator","label":"Author","values":["Peng, Lei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53269","local:Peng_grad.msu_0128D_22317","https://doi.org/doi:10.25335/c36a-9d51"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Non-destructive evaluation (NDE) is essential for ensuring structural integrity and operational safety across aerospace, energy, transportation, and advanced manufacturing industries. Among various NDE techniques, electromagnetic (EM) methods—such as eddy current testing—are widely adopted for inspecting conductive materials due to their high sensitivity, rapid inspection capability, and cost effectiveness. However, conventional EM NDE probes are predominantly rigid, which limits their applicability to complex three-dimensional geometries. In practical inspection scenarios such as pipelines and curved industrial components, poor surface conformity leads to lift-off variations, significantly degrading signal stability, inspection accuracy, and defect detectability. To address these challenges, this dissertation presents a comprehensive framework for the design, theoretical modeling, fabrication, and integration of flexible and stretchable EM NDE sensor array systems. Two complementary substrate materials are systematically evaluated: Polyimide (PI), which offers high mechanical strength, dimensional stability, and chemical endurance for fine circuit integration in harsh environments; and silicone rubber, whose low Young's modulus and hyper-elasticity enable soft compliance and deep conformal contact to minimize lift-off uncertainties. Based on these flexible and stretchable substrate platforms, a series of novel sensor arrays and advanced electromagnetic field control methodologies are developed. A flexible differential capacitive sensor array probe fabricated on a PI substrate is developed for pipeline inspection. The differential architecture effectively suppresses common-mode lift-off noise, enabling cost-effective, low-frequency operation across varying pipe diameters. A stretchable eddy current array embedded in the silicone rubber is developed. Unlike conventional non-stretchable PI-based probes, this deformable platform accommodates complex 3D surface deformations, eliminating lift-off fluctuations on compound curvatures. A theoretical framework and mathematical model for phase amplitude-controlled eddy current (PACEC) technique are established. This method allows dynamic steering of the eddy current, providing enhanced directional defect sensitivity. Finally, a novel 3D shape-reconstruction system utilizing flexible differential inductive sensor arrays is developed. Integrated with a miniaturized signal processing unit and reconstruction algorithm, the system provides a solution for real-time shape monitoring. The realization of these advanced capabilities demonstrates that flexible sensor arrays represent a crucial development direction for next-generation electromagnetic NDE, offering new design paradigms and practical solutions for challenging industrial inspection scenarios.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (100 p.) : ill."]},{"key":"dc:title","label":"Title","values":["ADVANCED FLEXIBLE AND STRETCHABLE ELECTROMAGNETIC NDE SENSORS ARRAY"]}]}],"canonical_facts":{"dc:contributor":["Deng, Yiming","Udpa, Lalita","Udpa, Satshi","Han, Ming","Haq, Mahmoodul","Mukherjee, Saptarshi"],"dc:creator":["Peng, Lei"],"dc:date":["2026"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Electrical and Computer Engineering - Doctor of Philosophy, 2026","Non-destructive evaluation (NDE) is essential for ensuring structural integrity and operational safety across aerospace, energy, transportation, and advanced manufacturing industries. Among various NDE techniques, electromagnetic (EM) methods—such as eddy current testing—are widely adopted for inspecting conductive materials due to their high sensitivity, rapid inspection capability, and cost effectiveness. However, conventional EM NDE probes are predominantly rigid, which limits their applicability to complex three-dimensional geometries. In practical inspection scenarios such as pipelines and curved industrial components, poor surface conformity leads to lift-off variations, significantly degrading signal stability, inspection accuracy, and defect detectability. To address these challenges, this dissertation presents a comprehensive framework for the design, theoretical modeling, fabrication, and integration of flexible and stretchable EM NDE sensor array systems. Two complementary substrate materials are systematically evaluated: Polyimide (PI), which offers high mechanical strength, dimensional stability, and chemical endurance for fine circuit integration in harsh environments; and silicone rubber, whose low Young's modulus and hyper-elasticity enable soft compliance and deep conformal contact to minimize lift-off uncertainties. Based on these flexible and stretchable substrate platforms, a series of novel sensor arrays and advanced electromagnetic field control methodologies are developed. A flexible differential capacitive sensor array probe fabricated on a PI substrate is developed for pipeline inspection. The differential architecture effectively suppresses common-mode lift-off noise, enabling cost-effective, low-frequency operation across varying pipe diameters. A stretchable eddy current array embedded in the silicone rubber is developed. Unlike conventional non-stretchable PI-based probes, this deformable platform accommodates complex 3D surface deformations, eliminating lift-off fluctuations on compound curvatures. A theoretical framework and mathematical model for phase amplitude-controlled eddy current (PACEC) technique are established. This method allows dynamic steering of the eddy current, providing enhanced directional defect sensitivity. Finally, a novel 3D shape-reconstruction system utilizing flexible differential inductive sensor arrays is developed. Integrated with a miniaturized signal processing unit and reconstruction algorithm, the system provides a solution for real-time shape monitoring. The realization of these advanced capabilities demonstrates that flexible sensor arrays represent a crucial development direction for next-generation electromagnetic NDE, offering new design paradigms and practical solutions for challenging industrial inspection scenarios.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (100 p.) : ill."],"dc:identifier":["etd:53269","local:Peng_grad.msu_0128D_22317","https://doi.org/doi:10.25335/c36a-9d51"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Electrical engineering","Engineering"],"dc:title":["ADVANCED FLEXIBLE AND STRETCHABLE ELECTROMAGNETIC NDE SENSORS ARRAY"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:44Z"}