{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_53316"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_53316","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Investigation of Losses of an Oil-Injected Helium Screw Compressor","abstract":"Thesis (Ph.D.)--Michigan State University. Mechanical Engineering - Doctor of Philosophy, 2026","abstract_html":"Thesis (Ph.D.)--Michigan State University. Mechanical Engineering - Doctor of Philosophy, 2026","abstract_has_math":false,"creators":["Anthony, Scott Elton"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Engeda, Abraham","Hasan, Nusair","Benard, Andre","Muller, Nobert","Liao, Wei"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:47Z","subjects":["Mechanical engineering"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53316","local:Anthony_grad.msu_0128D_22370"],"render_values":[{"text":"etd:53316","href":null,"code":true},{"text":"local:Anthony_grad.msu_0128D_22370","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/cncq-2402","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/cncq-2402","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_53316","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Engeda, Abraham","Hasan, Nusair","Benard, Andre","Muller, Nobert","Liao, Wei"]},{"key":"dc:creator","label":"Author","values":["Anthony, Scott Elton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53316","local:Anthony_grad.msu_0128D_22370","https://doi.org/doi:10.25335/cncq-2402"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Mechanical Engineering - Doctor of Philosophy, 2026","Oil-Injected (e.g. flooded) twin rotary screw compressors are widely used in the field of helium cryogenics to provide the thermodynamic availability necessary to operate a cryogenic plant. While this was not always the case, improvements to the manufacturing process of the helically shaped compressor rotors have made screw compressors a commercially viable option since the 1970's. Higher throughput, reliability, operating efficiency for variable loads and low vibration compared to any other commercially available positive displacement compressors, made the rotary screw compressor the preferred choice for helium refrigeration systems.Due to helium’s low normal boiling point (NBP, approximately 4.2 K for helium-4) and its inability to freeze (except at high pressures), helium is the only known working fluid that can be used in refrigeration systems where operating temperatures close to absolute zero are required. The process of cooling helium from ambient temperature (around 300 K) to its NBP is highly energy intensive. For large and efficient helium refrigerators, approximately 250 W of actual input power is required for 1 W of cooling at 4.2 K and 750 W at 2 K compared to 0.25 W for home refrigerators. Currently, in large systems, compressors account for approximately one-half of input power losses or two-thirds of the total system losses; thus, the compressor efficiency has the maximum influence on the overall system efficiency. The focus of this research is to investigate the various inherent loss mechanisms and the influences of operating parameters on individual losses and on the overall compressor system efficiency. Primary parameters that will be investigated include built-in volume ratio, pressure ratio, oil injection temperature, and oil injection mass flow rate on the inherent losses that are grouped into four loss categories (shown in Figure 1.15 & Figure 4.1). To aid in the investigation, a one-dimensional model of the helium-oil compression process through a screw compressor is developed and validated to experimental data. A parameter sweep over the typical operating range of these helium compressor systems is conducted utilizing the validated one-dimensional model to develop generalized equations – functionally dependent on main operating parameters – to predict each loss and overall compressor system efficiency. The one-dimensional model and generalized model results are used to gain insight into how to improve compressor efficiency, understand the dependence of individual operating parameters have on each loss, and specific design changes necessary to accomplish the improvements.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (188 p.) : ill."]},{"key":"dc:title","label":"Title","values":["Investigation of Losses of an Oil-Injected Helium Screw Compressor"]}]}],"canonical_facts":{"dc:contributor":["Engeda, Abraham","Hasan, Nusair","Benard, Andre","Muller, Nobert","Liao, Wei"],"dc:creator":["Anthony, Scott Elton"],"dc:date":["2026"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Mechanical Engineering - Doctor of Philosophy, 2026","Oil-Injected (e.g. flooded) twin rotary screw compressors are widely used in the field of helium cryogenics to provide the thermodynamic availability necessary to operate a cryogenic plant. While this was not always the case, improvements to the manufacturing process of the helically shaped compressor rotors have made screw compressors a commercially viable option since the 1970's. Higher throughput, reliability, operating efficiency for variable loads and low vibration compared to any other commercially available positive displacement compressors, made the rotary screw compressor the preferred choice for helium refrigeration systems.Due to helium’s low normal boiling point (NBP, approximately 4.2 K for helium-4) and its inability to freeze (except at high pressures), helium is the only known working fluid that can be used in refrigeration systems where operating temperatures close to absolute zero are required. The process of cooling helium from ambient temperature (around 300 K) to its NBP is highly energy intensive. For large and efficient helium refrigerators, approximately 250 W of actual input power is required for 1 W of cooling at 4.2 K and 750 W at 2 K compared to 0.25 W for home refrigerators. Currently, in large systems, compressors account for approximately one-half of input power losses or two-thirds of the total system losses; thus, the compressor efficiency has the maximum influence on the overall system efficiency. The focus of this research is to investigate the various inherent loss mechanisms and the influences of operating parameters on individual losses and on the overall compressor system efficiency. Primary parameters that will be investigated include built-in volume ratio, pressure ratio, oil injection temperature, and oil injection mass flow rate on the inherent losses that are grouped into four loss categories (shown in Figure 1.15 & Figure 4.1). To aid in the investigation, a one-dimensional model of the helium-oil compression process through a screw compressor is developed and validated to experimental data. A parameter sweep over the typical operating range of these helium compressor systems is conducted utilizing the validated one-dimensional model to develop generalized equations – functionally dependent on main operating parameters – to predict each loss and overall compressor system efficiency. The one-dimensional model and generalized model results are used to gain insight into how to improve compressor efficiency, understand the dependence of individual operating parameters have on each loss, and specific design changes necessary to accomplish the improvements.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (188 p.) : ill."],"dc:identifier":["etd:53316","local:Anthony_grad.msu_0128D_22370","https://doi.org/doi:10.25335/cncq-2402"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Mechanical engineering"],"dc:title":["Investigation of Losses of an Oil-Injected Helium Screw Compressor"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:47Z"}