{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_53427"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_53427","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"CONTROL OF NITROGEN RELATED DEFECTS IN DOPED SINGLE CRYSTAL DIAMOND GROWN VIA CHEMICAL VAPOR DEPOSITION","abstract":"Thesis (Ph.D.)--Michigan State University. Materials Science and Engineering - Doctor of Philosophy, 2026","abstract_html":"Thesis (Ph.D.)--Michigan State University. Materials Science and Engineering - Doctor of Philosophy, 2026","abstract_has_math":false,"creators":["Frechette-Roberts, Sarah"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Nicley, Shannon S.","Becker, Jonas N.","Zevalkink, Alexandra","Morelli, Donald"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T18:59:53Z","subjects":["Materials Science"],"languages":["eng"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53427","local:FrechetteRoberts_grad.msu_0128D_22489"],"render_values":[{"text":"etd:53427","href":null,"code":true},{"text":"local:FrechetteRoberts_grad.msu_0128D_22489","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/z6nc-v363","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/z6nc-v363","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_53427","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nicley, Shannon S.","Becker, Jonas N.","Zevalkink, Alexandra","Morelli, Donald"]},{"key":"dc:creator","label":"Author","values":["Frechette-Roberts, Sarah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["text","Electronic dissertations"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:53427","local:FrechetteRoberts_grad.msu_0128D_22489","https://doi.org/doi:10.25335/z6nc-v363"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Michigan State University. Materials Science and Engineering - Doctor of Philosophy, 2026","Quantum sensing holds great potential for many intriguing applications such as vectormagnetometry for magnetic field navigation in GPS disallowed scenarios and nanoscale magnetic resonance imaging (MRI). The negatively charged nitrogen vacancy defect (NV−) in diamond is a promising candidate for quantum sensing applications. A key advantage of the NV is its atomic size, which enables extraordinary spatial precision by single centers placed deterministically with minimal damage to the surrounding diamond lattice. This has been accomplished with ultrafast laser writing, however the defect creation process, which creates vacancies in the diamond lattice with a femtosecond laser pulse and then diffuses them at lower laser power until they find single substitutional nitrogen atoms to form the NV− centers, requires a very particular kind of substrate. The diamond lattice needs to contain sufficient substitutional nitrogen to allow for the NV− formation but also needs to have a very low background of NV− so that the written defects are single centers and distinguishable during the writing process. Furthermore, the high index of refraction of diamond causes the laser focal spot to be extended in the direction of the writing beam, and therefore the NV− formation can occur far away from the surface where their sensitivity would be the highest. A materials engineering challenge, developing ideal laser writing substrates, aimed at improving resolution of quantum sensors through fabrication of arrays of single NV− centers was explored in this work. The ideal single crystal diamond (SCD) substrate contains a delta doped layer of single substitutional nitrogen to overcome the inaccuracy in depth placement, and very low NV− background. A parametric study of a bell jar style microwave plasma assisted chemical vapor deposition (CVD) reactor was performed to address this materials engineering challenge. The effects of substrate temperature, reactor pressure, substrate offcut, and substrate surface preparation on the incorporation of nitrogen related defects was determined using characterization techniques including Fourier-transform infrared spectroscopy (FTIR), Ultra-violet spectroscopy (UV-Vis), Raman spectroscopy, photoluminescent (PL) spectroscopy, Atomic Force Microscopy (AFM), Differential Interference Contrast Microscopy (DICM), and Electron Paramagnetic Resonance (EPR). Expansion of the operation region of the CVD reactor to a low growth rate regime was assessed to improve crystalline quality and reduce delta doped layer thickness. Finally, an investigation into surface preparation techniques was completed to normalize the substrate surface condition prior to deposition, ensuring quality growth and improving sensitivity of nitrogen incorporation due to deposition parameters. This dissertation establishes a surface preparation method to normalize the substrate surface condition. Next, it validates growth quality in a low growth rate regime expanding the operation region of the CVD reactor. Lastly, the sensitivity of nitrogen incorporation caused by varying reactor parameters is investigated. To accurately determine the concentration of substitutional nitrogen, a complex infrared absorption feature was deconvoluted to isolate the absorption due to single substitutional nitrogen defects. The more accurately defined FTIR absorption peak area was calibrated against spin concentration measured via EPR. These results elucidate the effectiveness of preparing laser writing substrates in the current bell jar style reactor and more broadly study the factors affecting nitrogen incorporation during CVD growth.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1 online resource (136 p.) : ill."]},{"key":"dc:title","label":"Title","values":["CONTROL OF NITROGEN RELATED DEFECTS IN DOPED SINGLE CRYSTAL DIAMOND GROWN VIA CHEMICAL VAPOR DEPOSITION"]}]}],"canonical_facts":{"dc:contributor":["Nicley, Shannon S.","Becker, Jonas N.","Zevalkink, Alexandra","Morelli, Donald"],"dc:creator":["Frechette-Roberts, Sarah"],"dc:date":["2026"],"dc:description":["Thesis (Ph.D.)--Michigan State University. Materials Science and Engineering - Doctor of Philosophy, 2026","Quantum sensing holds great potential for many intriguing applications such as vectormagnetometry for magnetic field navigation in GPS disallowed scenarios and nanoscale magnetic resonance imaging (MRI). The negatively charged nitrogen vacancy defect (NV−) in diamond is a promising candidate for quantum sensing applications. A key advantage of the NV is its atomic size, which enables extraordinary spatial precision by single centers placed deterministically with minimal damage to the surrounding diamond lattice. This has been accomplished with ultrafast laser writing, however the defect creation process, which creates vacancies in the diamond lattice with a femtosecond laser pulse and then diffuses them at lower laser power until they find single substitutional nitrogen atoms to form the NV− centers, requires a very particular kind of substrate. The diamond lattice needs to contain sufficient substitutional nitrogen to allow for the NV− formation but also needs to have a very low background of NV− so that the written defects are single centers and distinguishable during the writing process. Furthermore, the high index of refraction of diamond causes the laser focal spot to be extended in the direction of the writing beam, and therefore the NV− formation can occur far away from the surface where their sensitivity would be the highest. A materials engineering challenge, developing ideal laser writing substrates, aimed at improving resolution of quantum sensors through fabrication of arrays of single NV− centers was explored in this work. The ideal single crystal diamond (SCD) substrate contains a delta doped layer of single substitutional nitrogen to overcome the inaccuracy in depth placement, and very low NV− background. A parametric study of a bell jar style microwave plasma assisted chemical vapor deposition (CVD) reactor was performed to address this materials engineering challenge. The effects of substrate temperature, reactor pressure, substrate offcut, and substrate surface preparation on the incorporation of nitrogen related defects was determined using characterization techniques including Fourier-transform infrared spectroscopy (FTIR), Ultra-violet spectroscopy (UV-Vis), Raman spectroscopy, photoluminescent (PL) spectroscopy, Atomic Force Microscopy (AFM), Differential Interference Contrast Microscopy (DICM), and Electron Paramagnetic Resonance (EPR). Expansion of the operation region of the CVD reactor to a low growth rate regime was assessed to improve crystalline quality and reduce delta doped layer thickness. Finally, an investigation into surface preparation techniques was completed to normalize the substrate surface condition prior to deposition, ensuring quality growth and improving sensitivity of nitrogen incorporation due to deposition parameters. This dissertation establishes a surface preparation method to normalize the substrate surface condition. Next, it validates growth quality in a low growth rate regime expanding the operation region of the CVD reactor. Lastly, the sensitivity of nitrogen incorporation caused by varying reactor parameters is investigated. To accurately determine the concentration of substitutional nitrogen, a complex infrared absorption feature was deconvoluted to isolate the absorption due to single substitutional nitrogen defects. The more accurately defined FTIR absorption peak area was calibrated against spin concentration measured via EPR. These results elucidate the effectiveness of preparing laser writing substrates in the current bell jar style reactor and more broadly study the factors affecting nitrogen incorporation during CVD growth.","Description based on online resource. Title from PDF t.p. (Michigan State University Fedora Repository, viewed ).","Includes bibliographical references."],"dc:format":["application/pdf","1 online resource (136 p.) : ill."],"dc:identifier":["etd:53427","local:FrechetteRoberts_grad.msu_0128D_22489","https://doi.org/doi:10.25335/z6nc-v363"],"dc:language":["eng"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Materials Science"],"dc:title":["CONTROL OF NITROGEN RELATED DEFECTS IN DOPED SINGLE CRYSTAL DIAMOND GROWN VIA CHEMICAL VAPOR DEPOSITION"],"dc:type":["text","Electronic dissertations"]},"updated_at":"2026-11-18T18:59:53Z"}