{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etd-restricted-1224"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etd-restricted-1224","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"DEVELOPMENT OF A THREE-DIMENSIONAL GRAPHENE ELECTRODE DIELECTROPHORETIC DEVICE","abstract":"Graphene paper is a novel material that features outstanding electrical and thermal properties owing to the unique chemical structure of graphene. Separately, dielectrophoresis (DEP) has been used in microfluidic devices to trap, sort, and identify particles/cells, with the advantages of low sample volume requirements and fast analysis. The three dimensional (3D) DEP microdevice constructed from graphene paper and double sided tape that is described in this thesis has higher sample throughput and more versatile functionalities than traditional two dimensional (2D) DEP devices. To characterize the device, we conducted a series of alternating current (AC) DEP experiments on 6.08 μm diameter polystyrene beads suspended in a spectrum of conductivities from 1.0 × 10-4 S/m to 1.3 S/m. The experimental results agree with both theoretical predictions and previously reported experiment values. This device will be instrumental in testing red blood cells for cholesterol inclusion in the membrane, which is more closely coupled to adverse cardiovascular events than currently measured plasma cholesterol. This subsequent work is important because the 3D graphene paper microdevice may be able to discern membrane cholesterol in a point of care diagnostic microdevice.","abstract_html":"Graphene paper is a novel material that features outstanding electrical and thermal properties owing to the unique chemical structure of graphene. Separately, dielectrophoresis (DEP) has been used in microfluidic devices to trap, sort, and identify particles/cells, with the advantages of low sample volume requirements and fast analysis. The three dimensional (3D) DEP microdevice constructed from graphene paper and double sided tape that is described in this thesis has higher sample throughput and more versatile functionalities than traditional two dimensional (2D) DEP devices. To characterize the device, we conducted a series of alternating current (AC) DEP experiments on 6.08 μm diameter polystyrene beads suspended in a spectrum of conductivities from 1.0 × 10-4 S/m to 1.3 S/m. The experimental results agree with both theoretical predictions and previously reported experiment values. This device will be instrumental in testing red blood cells for cholesterol inclusion in the membrane, which is more closely coupled to adverse cardiovascular events than currently measured plasma cholesterol. This subsequent work is important because the 3D graphene paper microdevice may be able to discern membrane cholesterol in a point of care diagnostic microdevice.","abstract_has_math":false,"creators":["Xie, Hongyu"],"institution":null,"degree_name":"Master of Science in Chemical Engineering (MS)","degree_level":"Master's Thesis","degree_discipline":"Department of Chemical Engineering","degree_department":null,"school":null,"contributors":["Adrienne Minerick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:16:09Z","subjects":["Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etd-restricted/224"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etd-restricted/224","href":"https://digitalcommons.mtu.edu/etd-restricted/224","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etd-restricted/224","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etd-restricted/224","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetd-restricted-1224","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Adrienne Minerick"]},{"key":"dc:creator","label":"Author","values":["Xie, Hongyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-11T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etd-restricted/224","https://digitalcommons.mtu.edu/etd-restricted/224"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Graphene paper is a novel material that features outstanding electrical and thermal properties owing to the unique chemical structure of graphene. Separately, dielectrophoresis (DEP) has been used in microfluidic devices to trap, sort, and identify particles/cells, with the advantages of low sample volume requirements and fast analysis. The three dimensional (3D) DEP microdevice constructed from graphene paper and double sided tape that is described in this thesis has higher sample throughput and more versatile functionalities than traditional two dimensional (2D) DEP devices. To characterize the device, we conducted a series of alternating current (AC) DEP experiments on 6.08 μm diameter polystyrene beads suspended in a spectrum of conductivities from 1.0 × 10-4 S/m to 1.3 S/m. The experimental results agree with both theoretical predictions and previously reported experiment values. This device will be instrumental in testing red blood cells for cholesterol inclusion in the membrane, which is more closely coupled to adverse cardiovascular events than currently measured plasma cholesterol. This subsequent work is important because the 3D graphene paper microdevice may be able to discern membrane cholesterol in a point of care diagnostic microdevice."]},{"key":"dc:title","label":"Title","values":["DEVELOPMENT OF A THREE-DIMENSIONAL GRAPHENE ELECTRODE DIELECTROPHORETIC DEVICE"]}]}],"canonical_facts":{"dc:contributor":["Adrienne Minerick"],"dc:creator":["Xie, Hongyu"],"dc:date.available":["2015-01-11T08:00:00Z"],"dc:date.created":["2014-01-01T08:00:00Z"],"dc:description.abstract":["Graphene paper is a novel material that features outstanding electrical and thermal properties owing to the unique chemical structure of graphene. Separately, dielectrophoresis (DEP) has been used in microfluidic devices to trap, sort, and identify particles/cells, with the advantages of low sample volume requirements and fast analysis. The three dimensional (3D) DEP microdevice constructed from graphene paper and double sided tape that is described in this thesis has higher sample throughput and more versatile functionalities than traditional two dimensional (2D) DEP devices. To characterize the device, we conducted a series of alternating current (AC) DEP experiments on 6.08 μm diameter polystyrene beads suspended in a spectrum of conductivities from 1.0 × 10-4 S/m to 1.3 S/m. The experimental results agree with both theoretical predictions and previously reported experiment values. This device will be instrumental in testing red blood cells for cholesterol inclusion in the membrane, which is more closely coupled to adverse cardiovascular events than currently measured plasma cholesterol. This subsequent work is important because the 3D graphene paper microdevice may be able to discern membrane cholesterol in a point of care diagnostic microdevice."],"dc:identifier":["10.37099/mtu.dc.etd-restricted/224","https://digitalcommons.mtu.edu/etd-restricted/224"],"dc:subject":["Chemical Engineering"],"dc:title":["DEVELOPMENT OF A THREE-DIMENSIONAL GRAPHENE ELECTRODE DIELECTROPHORETIC DEVICE"],"thesis:degree_discipline":["Department of Chemical Engineering"],"thesis:degree_level":["Master's Thesis"],"thesis:degree_name":["Master of Science in Chemical Engineering (MS)"]},"updated_at":"2026-11-19T08:16:09Z"}