{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1133"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1133","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"Finite Element Modeling of Active and Passive Behavior of the Human Tibialis Anterior: A Preliminary Approach","abstract":"This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography. Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for passive stretching and active contraction was theorized, with the aponeuroses bearing the majority of the load due to their high stiffness. Though the model will require future iterations to make adjustments, several promising conclusions were drawn during analysis. Fluid pressure distributions mimic those of the volumetric strain, and provide a better prediction of IMP than hydrostatic pressure. Reaction forces and pressure readings can be iterated to a reasonable level of accuracy. A thorough list of recommendations was compiled in order to guide the future direction of the model. Fluid pressures for the active contractile simulations were higher than the expected IMP values, likely owing to the stiffness of the aponeuroses being greater than necessary. Several options for addressing this issue were proposed, such as decreased aponeurosis length and graduated thickness and stiffness of the elements in the extremes of the parts.","abstract_html":"This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography. Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for passive stretching and active contraction was theorized, with the aponeuroses bearing the majority of the load due to their high stiffness. Though the model will require future iterations to make adjustments, several promising conclusions were drawn during analysis. Fluid pressure distributions mimic those of the volumetric strain, and provide a better prediction of IMP than hydrostatic pressure. Reaction forces and pressure readings can be iterated to a reasonable level of accuracy. A thorough list of recommendations was compiled in order to guide the future direction of the model. Fluid pressures for the active contractile simulations were higher than the expected IMP values, likely owing to the stiffness of the aponeuroses being greater than necessary. Several options for addressing this issue were proposed, such as decreased aponeurosis length and graduated thickness and stiffness of the elements in the extremes of the parts.","abstract_has_math":false,"creators":["Joda, David"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Report","degree_discipline":"Department of Mechanical Engineering-Engineering Mechanics","degree_department":null,"school":null,"contributors":["Gregory Odegard"],"advisors":[],"committee_chairs":[],"committee_members":["Mohammad Rastgaar-Aagaah","Tammy Haut Donahue"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:16:37Z","subjects":["Finite Element Analysis","Intramuscular Pressure","Human Tissue","Computational Biomechanics","Biomechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/130"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/130","href":"https://digitalcommons.mtu.edu/etdr/130","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/130","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/130","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1133","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gregory Odegard"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mohammad Rastgaar-Aagaah","Tammy Haut Donahue"]},{"key":"dc:creator","label":"Author","values":["Joda, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering-Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Finite Element Analysis","Intramuscular Pressure","Human Tissue","Computational Biomechanics","Biomechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/130","https://digitalcommons.mtu.edu/etdr/130"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography. Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for passive stretching and active contraction was theorized, with the aponeuroses bearing the majority of the load due to their high stiffness. Though the model will require future iterations to make adjustments, several promising conclusions were drawn during analysis. Fluid pressure distributions mimic those of the volumetric strain, and provide a better prediction of IMP than hydrostatic pressure. Reaction forces and pressure readings can be iterated to a reasonable level of accuracy. A thorough list of recommendations was compiled in order to guide the future direction of the model. Fluid pressures for the active contractile simulations were higher than the expected IMP values, likely owing to the stiffness of the aponeuroses being greater than necessary. Several options for addressing this issue were proposed, such as decreased aponeurosis length and graduated thickness and stiffness of the elements in the extremes of the parts."]},{"key":"dc:title","label":"Title","values":["Finite Element Modeling of Active and Passive Behavior of the Human Tibialis Anterior: A Preliminary Approach"]}]}],"canonical_facts":{"dc:contributor":["Gregory Odegard"],"dc:contributor.committeemember":["Mohammad Rastgaar-Aagaah","Tammy Haut Donahue"],"dc:creator":["Joda, David"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography. Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for passive stretching and active contraction was theorized, with the aponeuroses bearing the majority of the load due to their high stiffness. Though the model will require future iterations to make adjustments, several promising conclusions were drawn during analysis. Fluid pressure distributions mimic those of the volumetric strain, and provide a better prediction of IMP than hydrostatic pressure. Reaction forces and pressure readings can be iterated to a reasonable level of accuracy. A thorough list of recommendations was compiled in order to guide the future direction of the model. Fluid pressures for the active contractile simulations were higher than the expected IMP values, likely owing to the stiffness of the aponeuroses being greater than necessary. Several options for addressing this issue were proposed, such as decreased aponeurosis length and graduated thickness and stiffness of the elements in the extremes of the parts."],"dc:identifier":["10.37099/mtu.dc.etdr/130","https://digitalcommons.mtu.edu/etdr/130"],"dc:subject":["Finite Element Analysis","Intramuscular Pressure","Human Tissue","Computational Biomechanics","Biomechanical Engineering"],"dc:title":["Finite Element Modeling of Active and Passive Behavior of the Human Tibialis Anterior: A Preliminary Approach"],"thesis:degree_discipline":["Department of Mechanical Engineering-Engineering Mechanics"],"thesis:degree_level":["Open Access Master's Report"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:16:37Z"}