{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1331"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1331","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"A C++ PROGRAM TO ESTIMATE THE LOADING OF AN OIL-IMMERSED TRANSFORMER","abstract":"As utilities are pushed to do more with less and with one of the biggest costs being transformers it is not surprising that they are pushed to their maximum thermal limits. Considerations such as top oil temperature, top duct temperature, hotspot temperature, and the percent loss of life need to be taken into account when loading a transformer above its rated nameplate. This project builds off of the work done in previous reports and computer programs that the sponsor has used successfully over the years. This report will cover how a C++ program was developed and implemented. This program is to help a utility estimate the maximum load that can be applied to a transformer based on maximum allowable thermal temperatures and a percent loss of life, in a given year that is defined by the user. The output data from the program shows the maximum load that could be applied to their transformer fleet if needed. This program will replace the outdated program that is currently in use by the sponsor. This report will serve as a user guide for the new program, covering the changes that were made to the new program and what has stayed the same. The goal of this program was to replace an out-of-date program, not to add or delete functionality from the old program. Therefore if a user was familiar with the old program they should have no problem using the new program presented here.","abstract_html":"As utilities are pushed to do more with less and with one of the biggest costs being transformers it is not surprising that they are pushed to their maximum thermal limits. Considerations such as top oil temperature, top duct temperature, hotspot temperature, and the percent loss of life need to be taken into account when loading a transformer above its rated nameplate. This project builds off of the work done in previous reports and computer programs that the sponsor has used successfully over the years. This report will cover how a C++ program was developed and implemented. This program is to help a utility estimate the maximum load that can be applied to a transformer based on maximum allowable thermal temperatures and a percent loss of life, in a given year that is defined by the user. The output data from the program shows the maximum load that could be applied to their transformer fleet if needed. This program will replace the outdated program that is currently in use by the sponsor. This report will serve as a user guide for the new program, covering the changes that were made to the new program and what has stayed the same. The goal of this program was to replace an out-of-date program, not to add or delete functionality from the old program. Therefore if a user was familiar with the old program they should have no problem using the new program presented here.","abstract_has_math":false,"creators":["Drumm, Dustin M."],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MS)","degree_level":"Campus Access Master's Report","degree_discipline":"Department of Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Bruce Mork","John Lukowski"],"advisors":[],"committee_chairs":[],"committee_members":["Gowtham S.","Sumit Paudyal"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:16:54Z","subjects":["Transformer","Program","C++","C57.91","Simulation","Load","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/237"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/237","href":"https://digitalcommons.mtu.edu/etdr/237","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/237","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/237","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1331","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bruce Mork","John Lukowski"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gowtham S.","Sumit Paudyal"]},{"key":"dc:creator","label":"Author","values":["Drumm, Dustin M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-12-31T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Master's Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Transformer","Program","C++","C57.91","Simulation","Load","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/237","https://digitalcommons.mtu.edu/etdr/237"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As utilities are pushed to do more with less and with one of the biggest costs being transformers it is not surprising that they are pushed to their maximum thermal limits. Considerations such as top oil temperature, top duct temperature, hotspot temperature, and the percent loss of life need to be taken into account when loading a transformer above its rated nameplate. This project builds off of the work done in previous reports and computer programs that the sponsor has used successfully over the years. This report will cover how a C++ program was developed and implemented. This program is to help a utility estimate the maximum load that can be applied to a transformer based on maximum allowable thermal temperatures and a percent loss of life, in a given year that is defined by the user. The output data from the program shows the maximum load that could be applied to their transformer fleet if needed. This program will replace the outdated program that is currently in use by the sponsor. This report will serve as a user guide for the new program, covering the changes that were made to the new program and what has stayed the same. The goal of this program was to replace an out-of-date program, not to add or delete functionality from the old program. Therefore if a user was familiar with the old program they should have no problem using the new program presented here."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Due to legal issues that the sponsor (Consumers Energy) can face due to the program that was written and explained in this report from current and future customers as well as state and federal agencies the sponsor is requesting a permanent embargo. If a permanent embargo is not granted then Consumers Energy legal department needs to be contacted for a reasonable embargo end date.</p>"]},{"key":"dc:title","label":"Title","values":["A C++ PROGRAM TO ESTIMATE THE LOADING OF AN OIL-IMMERSED TRANSFORMER"]}]}],"canonical_facts":{"dc:contributor":["Bruce Mork","John Lukowski"],"dc:contributor.committeemember":["Gowtham S.","Sumit Paudyal"],"dc:creator":["Drumm, Dustin M."],"dc:date.available":["2017-12-31T08:00:00Z"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["As utilities are pushed to do more with less and with one of the biggest costs being transformers it is not surprising that they are pushed to their maximum thermal limits. Considerations such as top oil temperature, top duct temperature, hotspot temperature, and the percent loss of life need to be taken into account when loading a transformer above its rated nameplate. This project builds off of the work done in previous reports and computer programs that the sponsor has used successfully over the years. This report will cover how a C++ program was developed and implemented. This program is to help a utility estimate the maximum load that can be applied to a transformer based on maximum allowable thermal temperatures and a percent loss of life, in a given year that is defined by the user. The output data from the program shows the maximum load that could be applied to their transformer fleet if needed. This program will replace the outdated program that is currently in use by the sponsor. This report will serve as a user guide for the new program, covering the changes that were made to the new program and what has stayed the same. The goal of this program was to replace an out-of-date program, not to add or delete functionality from the old program. Therefore if a user was familiar with the old program they should have no problem using the new program presented here."],"dc:description.note":["<p>Due to legal issues that the sponsor (Consumers Energy) can face due to the program that was written and explained in this report from current and future customers as well as state and federal agencies the sponsor is requesting a permanent embargo. If a permanent embargo is not granted then Consumers Energy legal department needs to be contacted for a reasonable embargo end date.</p>"],"dc:identifier":["10.37099/mtu.dc.etdr/237","https://digitalcommons.mtu.edu/etdr/237"],"dc:subject":["Transformer","Program","C++","C57.91","Simulation","Load","Power and Energy"],"dc:title":["A C++ PROGRAM TO ESTIMATE THE LOADING OF AN OIL-IMMERSED TRANSFORMER"],"thesis:degree_discipline":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Campus Access Master's Report"],"thesis:degree_name":["Master of Science in Electrical Engineering (MS)"]},"updated_at":"2026-11-19T08:16:54Z"}