{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1408"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1408","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"Implantable Wireless Sensor Networks: Application to Measuring Temperature for In Vivo Detection of Infections","abstract":"It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 wireless sensor network (Texas Instruments). The sensor device is designed to monitor temperature at a fixation plate of a rodent under an infection model. Two prototypes of the system, T1 and T2, were designed and fabricated during this work. The sensors displayed good sensitivity, stability and reliability during the testing. The system was optimized for better timing accuracy to allow power management. Such a sensor could be used for long term monitoring of infections associated with orthopedic implants.","abstract_html":"It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 wireless sensor network (Texas Instruments). The sensor device is designed to monitor temperature at a fixation plate of a rodent under an infection model. Two prototypes of the system, T1 and T2, were designed and fabricated during this work. The sensors displayed good sensitivity, stability and reliability during the testing. The system was optimized for better timing accuracy to allow power management. Such a sensor could be used for long term monitoring of infections associated with orthopedic implants.","abstract_has_math":false,"creators":["Madappaly Veetil, Praharsh"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Biomedical Engineering","degree_department":null,"school":null,"contributors":["Keat Ghee Ong"],"advisors":[],"committee_chairs":[],"committee_members":["Bruce P. Lee","Smitha Rao"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:02Z","subjects":["temperature","sensor","thermistor","infection","wireless","implantable","Biomedical","Biomedical Devices and Instrumentation","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/356"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/356","href":"https://digitalcommons.mtu.edu/etdr/356","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/356","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/356","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1408","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Keat Ghee Ong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bruce P. Lee","Smitha Rao"]},{"key":"dc:creator","label":"Author","values":["Madappaly Veetil, Praharsh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["temperature","sensor","thermistor","infection","wireless","implantable","Biomedical","Biomedical Devices and Instrumentation","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/356","https://digitalcommons.mtu.edu/etdr/356"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 wireless sensor network (Texas Instruments). The sensor device is designed to monitor temperature at a fixation plate of a rodent under an infection model. Two prototypes of the system, T1 and T2, were designed and fabricated during this work. The sensors displayed good sensitivity, stability and reliability during the testing. The system was optimized for better timing accuracy to allow power management. Such a sensor could be used for long term monitoring of infections associated with orthopedic implants."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Please let me know if I made any mistakes.</p>"]},{"key":"dc:title","label":"Title","values":["Implantable Wireless Sensor Networks: Application to Measuring Temperature for In Vivo Detection of Infections"]}]}],"canonical_facts":{"dc:contributor":["Keat Ghee Ong"],"dc:contributor.committeemember":["Bruce P. Lee","Smitha Rao"],"dc:creator":["Madappaly Veetil, Praharsh"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 wireless sensor network (Texas Instruments). The sensor device is designed to monitor temperature at a fixation plate of a rodent under an infection model. Two prototypes of the system, T1 and T2, were designed and fabricated during this work. The sensors displayed good sensitivity, stability and reliability during the testing. The system was optimized for better timing accuracy to allow power management. Such a sensor could be used for long term monitoring of infections associated with orthopedic implants."],"dc:description.note":["<p>Please let me know if I made any mistakes.</p>"],"dc:identifier":["10.37099/mtu.dc.etdr/356","https://digitalcommons.mtu.edu/etdr/356"],"dc:subject":["temperature","sensor","thermistor","infection","wireless","implantable","Biomedical","Biomedical Devices and Instrumentation","Electrical and Electronics"],"dc:title":["Implantable Wireless Sensor Networks: Application to Measuring Temperature for In Vivo Detection of Infections"],"thesis:degree_discipline":["Department of Biomedical Engineering"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MS)"]},"updated_at":"2026-11-19T08:17:02Z"}