{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1453"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1453","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"DESIGN OF A SHAPE-MEMORY-ALLOY BASED TAB ROTATION ACTUATOR","abstract":"A shape memory alloy actuated wire actuated mechanism for tab rotation was designed, manufactured and tested. Antagonistic SMA wires are applied for activating the actuation to enable the tab rotate in both directions. Locking system and rotation sensor are comprised in this design. The system is supervised by a feedback rotation controller. Devices were fabricated with the shape memory alloy wire clamping mechanism and actuation with locking functions. The temperature-voltage relations of clamped SMA wires were predicted with an analytical model based on the thermomechanical study of NiTi done by Epps et al.[1] and Singh et al.[2]. The PID feedback controller was designed with optimized parameters to locate controlled voltage for precise tab angle actuation. The controller operation was tested with LabVIEW® System Design Software. With the feedback control, the relative differences between actuation angle and target angle were analyzed. Further investigation on this SMA –based tab rotation actuation were discussed including operation speed and accuracy.","abstract_html":"A shape memory alloy actuated wire actuated mechanism for tab rotation was designed, manufactured and tested. Antagonistic SMA wires are applied for activating the actuation to enable the tab rotate in both directions. Locking system and rotation sensor are comprised in this design. The system is supervised by a feedback rotation controller. Devices were fabricated with the shape memory alloy wire clamping mechanism and actuation with locking functions. The temperature-voltage relations of clamped SMA wires were predicted with an analytical model based on the thermomechanical study of NiTi done by Epps et al.[1] and Singh et al.[2]. The PID feedback controller was designed with optimized parameters to locate controlled voltage for precise tab angle actuation. The controller operation was tested with LabVIEW® System Design Software. With the feedback control, the relative differences between actuation angle and target angle were analyzed. Further investigation on this SMA –based tab rotation actuation were discussed including operation speed and accuracy.","abstract_has_math":false,"creators":["Lu, Chao"],"institution":null,"degree_name":"Master of Science in Civil Engineering (MS)","degree_level":"Campus Access Master's Thesis","degree_discipline":"Department of Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Qingli Dai"],"advisors":[],"committee_chairs":[],"committee_members":["Hyungchul Yoon","Bo Chen"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:02Z","subjects":["SMA","tab rotation","proportional control","wire","blade actuator","resistivity heating","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/353"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/353","href":"https://digitalcommons.mtu.edu/etdr/353","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/353","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/353","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1453","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Qingli Dai"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hyungchul Yoon","Bo Chen"]},{"key":"dc:creator","label":"Author","values":["Lu, Chao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["SMA","tab rotation","proportional control","wire","blade actuator","resistivity heating","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/353","https://digitalcommons.mtu.edu/etdr/353"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A shape memory alloy actuated wire actuated mechanism for tab rotation was designed, manufactured and tested. Antagonistic SMA wires are applied for activating the actuation to enable the tab rotate in both directions. Locking system and rotation sensor are comprised in this design. The system is supervised by a feedback rotation controller. Devices were fabricated with the shape memory alloy wire clamping mechanism and actuation with locking functions. The temperature-voltage relations of clamped SMA wires were predicted with an analytical model based on the thermomechanical study of NiTi done by Epps et al.[1] and Singh et al.[2]. The PID feedback controller was designed with optimized parameters to locate controlled voltage for precise tab angle actuation. The controller operation was tested with LabVIEW® System Design Software. With the feedback control, the relative differences between actuation angle and target angle were analyzed. Further investigation on this SMA –based tab rotation actuation were discussed including operation speed and accuracy."]},{"key":"dc:title","label":"Title","values":["DESIGN OF A SHAPE-MEMORY-ALLOY BASED TAB ROTATION ACTUATOR"]}]}],"canonical_facts":{"dc:contributor":["Qingli Dai"],"dc:contributor.committeemember":["Hyungchul Yoon","Bo Chen"],"dc:creator":["Lu, Chao"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["A shape memory alloy actuated wire actuated mechanism for tab rotation was designed, manufactured and tested. Antagonistic SMA wires are applied for activating the actuation to enable the tab rotate in both directions. Locking system and rotation sensor are comprised in this design. The system is supervised by a feedback rotation controller. Devices were fabricated with the shape memory alloy wire clamping mechanism and actuation with locking functions. The temperature-voltage relations of clamped SMA wires were predicted with an analytical model based on the thermomechanical study of NiTi done by Epps et al.[1] and Singh et al.[2]. The PID feedback controller was designed with optimized parameters to locate controlled voltage for precise tab angle actuation. The controller operation was tested with LabVIEW® System Design Software. With the feedback control, the relative differences between actuation angle and target angle were analyzed. Further investigation on this SMA –based tab rotation actuation were discussed including operation speed and accuracy."],"dc:identifier":["10.37099/mtu.dc.etdr/353","https://digitalcommons.mtu.edu/etdr/353"],"dc:subject":["SMA","tab rotation","proportional control","wire","blade actuator","resistivity heating","Civil Engineering"],"dc:title":["DESIGN OF A SHAPE-MEMORY-ALLOY BASED TAB ROTATION ACTUATOR"],"thesis:degree_discipline":["Department of Civil and Environmental Engineering"],"thesis:degree_level":["Campus Access Master's Thesis"],"thesis:degree_name":["Master of Science in Civil Engineering (MS)"]},"updated_at":"2026-11-19T08:17:02Z"}