{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1563"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1563","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"CONSENSUS-BASED PROPORTIONAL-RESONANT CONTROL OF RENEWABLE ENERGY GENERATORS","abstract":"Distributed generation (DG) systems are getting progressive popularity due to their environmental friendly features, flexible modes of operation, and capability to work in remote areas. Renewable energy sources such as photovoltaic (PV) cells and wind turbines (WT) need power electronic inverters to connect to the utility grid for power transmission. Normally in a local area, multiple DG units from different renewable energy sources connect to the utility grid in the same location, which calls for reliable and robust control algorithms to cooperatively control and balance the power sharing among the DG units. In this thesis, a multi-level hierarchical control algorithm is proposed to regulate the power generation by multiple DG units, while the noises and disturbances including current harmonics (due to nonlinearities) and resonance frequency (due to higher order filters) are attenuated and rejected. Three cascaded (nested) control loops are designed, namely, inner loop, middle loop, and outer loop. The inner loop is the current control loop which includes a proportional-resonant (PR) controller to track the reference current signal by generating the input signal for the pulse width modulation (PWM) module, which actuates the power electronic switches. The middle loop is the power control loop which includes a proportional-integral (PI) controller to track the reference power signal by generating the reference current signal for the inner loop (current control loop). The outer loop is the consensus control loop which includes a consensus algorithm to balance the power sharing among DG units based on their maximum power capacity by generating the reference power signal for the middle loop (power control loop). Simulations are conducted in Matlab/Simulink for the case of single-phase grid- xvii connected DG units. The simulation results confirm the effectiveness of the proposed multi-level hierarchical control algorithm.","abstract_html":"Distributed generation (DG) systems are getting progressive popularity due to their environmental friendly features, flexible modes of operation, and capability to work in remote areas. Renewable energy sources such as photovoltaic (PV) cells and wind turbines (WT) need power electronic inverters to connect to the utility grid for power transmission. Normally in a local area, multiple DG units from different renewable energy sources connect to the utility grid in the same location, which calls for reliable and robust control algorithms to cooperatively control and balance the power sharing among the DG units. In this thesis, a multi-level hierarchical control algorithm is proposed to regulate the power generation by multiple DG units, while the noises and disturbances including current harmonics (due to nonlinearities) and resonance frequency (due to higher order filters) are attenuated and rejected. Three cascaded (nested) control loops are designed, namely, inner loop, middle loop, and outer loop. The inner loop is the current control loop which includes a proportional-resonant (PR) controller to track the reference current signal by generating the input signal for the pulse width modulation (PWM) module, which actuates the power electronic switches. The middle loop is the power control loop which includes a proportional-integral (PI) controller to track the reference power signal by generating the reference current signal for the inner loop (current control loop). The outer loop is the consensus control loop which includes a consensus algorithm to balance the power sharing among DG units based on their maximum power capacity by generating the reference power signal for the middle loop (power control loop). Simulations are conducted in Matlab/Simulink for the case of single-phase grid- xvii connected DG units. The simulation results confirm the effectiveness of the proposed multi-level hierarchical control algorithm.","abstract_has_math":false,"creators":["Buyuknalbant, Muhittin"],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MS)","degree_level":"Campus Access Master's Thesis","degree_discipline":"Department of Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Seyyedmohsen Azizi","Saeid V Nooshabadi"],"advisors":[],"committee_chairs":[],"committee_members":["Sumit Paudyal","Mahdi Shahbakhti"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:09Z","subjects":["consensus algorithm","proportional-resonant (PR)","cascaded control","proportional-integral","Matlab/Simulink.","Controls and Control Theory","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/411"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/411","href":"https://digitalcommons.mtu.edu/etdr/411","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/411","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/411","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1563","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Seyyedmohsen Azizi","Saeid V Nooshabadi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sumit Paudyal","Mahdi Shahbakhti"]},{"key":"dc:creator","label":"Author","values":["Buyuknalbant, Muhittin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["consensus algorithm","proportional-resonant (PR)","cascaded control","proportional-integral","Matlab/Simulink.","Controls and Control Theory","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/411","https://digitalcommons.mtu.edu/etdr/411"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Distributed generation (DG) systems are getting progressive popularity due to their environmental friendly features, flexible modes of operation, and capability to work in remote areas. Renewable energy sources such as photovoltaic (PV) cells and wind turbines (WT) need power electronic inverters to connect to the utility grid for power transmission. Normally in a local area, multiple DG units from different renewable energy sources connect to the utility grid in the same location, which calls for reliable and robust control algorithms to cooperatively control and balance the power sharing among the DG units. In this thesis, a multi-level hierarchical control algorithm is proposed to regulate the power generation by multiple DG units, while the noises and disturbances including current harmonics (due to nonlinearities) and resonance frequency (due to higher order filters) are attenuated and rejected. Three cascaded (nested) control loops are designed, namely, inner loop, middle loop, and outer loop. The inner loop is the current control loop which includes a proportional-resonant (PR) controller to track the reference current signal by generating the input signal for the pulse width modulation (PWM) module, which actuates the power electronic switches. The middle loop is the power control loop which includes a proportional-integral (PI) controller to track the reference power signal by generating the reference current signal for the inner loop (current control loop). The outer loop is the consensus control loop which includes a consensus algorithm to balance the power sharing among DG units based on their maximum power capacity by generating the reference power signal for the middle loop (power control loop). Simulations are conducted in Matlab/Simulink for the case of single-phase grid- xvii connected DG units. The simulation results confirm the effectiveness of the proposed multi-level hierarchical control algorithm."]},{"key":"dc:title","label":"Title","values":["CONSENSUS-BASED PROPORTIONAL-RESONANT CONTROL OF RENEWABLE ENERGY GENERATORS"]}]}],"canonical_facts":{"dc:contributor":["Seyyedmohsen Azizi","Saeid V Nooshabadi"],"dc:contributor.committeemember":["Sumit Paudyal","Mahdi Shahbakhti"],"dc:creator":["Buyuknalbant, Muhittin"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["Distributed generation (DG) systems are getting progressive popularity due to their environmental friendly features, flexible modes of operation, and capability to work in remote areas. Renewable energy sources such as photovoltaic (PV) cells and wind turbines (WT) need power electronic inverters to connect to the utility grid for power transmission. Normally in a local area, multiple DG units from different renewable energy sources connect to the utility grid in the same location, which calls for reliable and robust control algorithms to cooperatively control and balance the power sharing among the DG units. In this thesis, a multi-level hierarchical control algorithm is proposed to regulate the power generation by multiple DG units, while the noises and disturbances including current harmonics (due to nonlinearities) and resonance frequency (due to higher order filters) are attenuated and rejected. Three cascaded (nested) control loops are designed, namely, inner loop, middle loop, and outer loop. The inner loop is the current control loop which includes a proportional-resonant (PR) controller to track the reference current signal by generating the input signal for the pulse width modulation (PWM) module, which actuates the power electronic switches. The middle loop is the power control loop which includes a proportional-integral (PI) controller to track the reference power signal by generating the reference current signal for the inner loop (current control loop). The outer loop is the consensus control loop which includes a consensus algorithm to balance the power sharing among DG units based on their maximum power capacity by generating the reference power signal for the middle loop (power control loop). Simulations are conducted in Matlab/Simulink for the case of single-phase grid- xvii connected DG units. The simulation results confirm the effectiveness of the proposed multi-level hierarchical control algorithm."],"dc:identifier":["10.37099/mtu.dc.etdr/411","https://digitalcommons.mtu.edu/etdr/411"],"dc:subject":["consensus algorithm","proportional-resonant (PR)","cascaded control","proportional-integral","Matlab/Simulink.","Controls and Control Theory","Power and Energy"],"dc:title":["CONSENSUS-BASED PROPORTIONAL-RESONANT CONTROL OF RENEWABLE ENERGY GENERATORS"],"thesis:degree_discipline":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Campus Access Master's Thesis"],"thesis:degree_name":["Master of Science in Electrical Engineering (MS)"]},"updated_at":"2026-11-19T08:17:09Z"}