{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1845"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1845","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"INNOVATIVE FIN-TUBES FOR A STANDARD STAGGERED BUNDLE FAMILY LEADING TO SIGNIFICANT REDUCTIONS IN AIR-SIDE THERMAL AND PRESSURE-DROP RESISTANCES FOR A POPULAR HEAT-EXCHANGER – QUANTITATIVE CHARACTERIZATIONS BASED ON A UNIQUE SYNTHESIS OF EXPERIMENTS, MODELING, AND RELIABLE COMPUTATIONS","abstract":"This thesis describes a unique and useful semi-experimental approach for innovating fin-tubes – towards addressing critical issues of a popular heat exchanger that is extensively used in the modern power generation sector. The approach consists of a unique synthesis of experiments, modeling and reliable computations. These heat-exchangers involve transfer of heat from warm-to-hot air that flows across a tube-bundle into the flowing fluid within the finned tubes. For a specific pair of traditional and innovative fin-tube designs used in a standard staggered tube-bundle arrangement, the approach yields comparative values of air-side thermal and pressure-drop resistances on a per tube basis. Up to 40 - 60% improvement in per-tube energy efficiency parameter (ratio of rate of heat removal to consumed pumping power associated with pressure-drop) is demonstrated for the innovative fin-tube over the traditional one for commonly encountered conditions in the heat-exchangers of interest.","abstract_html":"This thesis describes a unique and useful semi-experimental approach for innovating fin-tubes – towards addressing critical issues of a popular heat exchanger that is extensively used in the modern power generation sector. The approach consists of a unique synthesis of experiments, modeling and reliable computations. These heat-exchangers involve transfer of heat from warm-to-hot air that flows across a tube-bundle into the flowing fluid within the finned tubes. For a specific pair of traditional and innovative fin-tube designs used in a standard staggered tube-bundle arrangement, the approach yields comparative values of air-side thermal and pressure-drop resistances on a per tube basis. Up to 40 - 60% improvement in per-tube energy efficiency parameter (ratio of rate of heat removal to consumed pumping power associated with pressure-drop) is demonstrated for the innovative fin-tube over the traditional one for commonly encountered conditions in the heat-exchangers of interest.","abstract_has_math":false,"creators":["Shinde, Nikhil"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Campus Access Master's Thesis","degree_discipline":"Department of Mechanical Engineering-Engineering Mechanics","degree_department":null,"school":null,"contributors":["Amitabh Narain"],"advisors":[],"committee_chairs":[],"committee_members":["Sunil Mehendale","V.C. Rao Komaravolu"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:40Z","subjects":["heat exchanger","fin tubes","staggered tube bundle","HRSGs","air-side thermal resistance","pressure drops","Heat Transfer, Combustion"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/751"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/751","href":"https://digitalcommons.mtu.edu/etdr/751","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/751","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/751","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1845","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Amitabh Narain"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sunil Mehendale","V.C. Rao Komaravolu"]},{"key":"dc:creator","label":"Author","values":["Shinde, Nikhil"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering-Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["heat exchanger","fin tubes","staggered tube bundle","HRSGs","air-side thermal resistance","pressure drops","Heat Transfer, Combustion"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/751","https://digitalcommons.mtu.edu/etdr/751"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes a unique and useful semi-experimental approach for innovating fin-tubes – towards addressing critical issues of a popular heat exchanger that is extensively used in the modern power generation sector. The approach consists of a unique synthesis of experiments, modeling and reliable computations. These heat-exchangers involve transfer of heat from warm-to-hot air that flows across a tube-bundle into the flowing fluid within the finned tubes. For a specific pair of traditional and innovative fin-tube designs used in a standard staggered tube-bundle arrangement, the approach yields comparative values of air-side thermal and pressure-drop resistances on a per tube basis. Up to 40 - 60% improvement in per-tube energy efficiency parameter (ratio of rate of heat removal to consumed pumping power associated with pressure-drop) is demonstrated for the innovative fin-tube over the traditional one for commonly encountered conditions in the heat-exchangers of interest."]},{"key":"dc:title","label":"Title","values":["INNOVATIVE FIN-TUBES FOR A STANDARD STAGGERED BUNDLE FAMILY LEADING TO SIGNIFICANT REDUCTIONS IN AIR-SIDE THERMAL AND PRESSURE-DROP RESISTANCES FOR A POPULAR HEAT-EXCHANGER – QUANTITATIVE CHARACTERIZATIONS BASED ON A UNIQUE SYNTHESIS OF EXPERIMENTS, MODELING, AND RELIABLE COMPUTATIONS"]}]}],"canonical_facts":{"dc:contributor":["Amitabh Narain"],"dc:contributor.committeemember":["Sunil Mehendale","V.C. Rao Komaravolu"],"dc:creator":["Shinde, Nikhil"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["This thesis describes a unique and useful semi-experimental approach for innovating fin-tubes – towards addressing critical issues of a popular heat exchanger that is extensively used in the modern power generation sector. The approach consists of a unique synthesis of experiments, modeling and reliable computations. These heat-exchangers involve transfer of heat from warm-to-hot air that flows across a tube-bundle into the flowing fluid within the finned tubes. For a specific pair of traditional and innovative fin-tube designs used in a standard staggered tube-bundle arrangement, the approach yields comparative values of air-side thermal and pressure-drop resistances on a per tube basis. Up to 40 - 60% improvement in per-tube energy efficiency parameter (ratio of rate of heat removal to consumed pumping power associated with pressure-drop) is demonstrated for the innovative fin-tube over the traditional one for commonly encountered conditions in the heat-exchangers of interest."],"dc:identifier":["10.37099/mtu.dc.etdr/751","https://digitalcommons.mtu.edu/etdr/751"],"dc:subject":["heat exchanger","fin tubes","staggered tube bundle","HRSGs","air-side thermal resistance","pressure drops","Heat Transfer, Combustion"],"dc:title":["INNOVATIVE FIN-TUBES FOR A STANDARD STAGGERED BUNDLE FAMILY LEADING TO SIGNIFICANT REDUCTIONS IN AIR-SIDE THERMAL AND PRESSURE-DROP RESISTANCES FOR A POPULAR HEAT-EXCHANGER – QUANTITATIVE CHARACTERIZATIONS BASED ON A UNIQUE SYNTHESIS OF EXPERIMENTS, MODELING, AND RELIABLE COMPUTATIONS"],"thesis:degree_discipline":["Department of Mechanical Engineering-Engineering Mechanics"],"thesis:degree_level":["Campus Access Master's Thesis"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:17:40Z"}