{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-1981"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-1981","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"MULTI-SCALE, CAPILLARY ASSISTED COPPER SURFACES FOR ENHANCED POOL BOILING HEAT TRANSFER PROCESSES","abstract":"Phase-change heat transfer through pool boiling process offers a promising thermal management solution in applications wherein conventional air or single-phase liquid-based cooling methods prove inefficient such as for high-power electronics. Pool boiling process, which utilizes the latent heat of evaporation, provides a robust and efficient way to efficiently dissipate the excessive heat generated in a small footprint area in particular as seen in CPUs (Central Processing Units), GPUs (Graphics Processing Units), LEDs (Light Emitting Diodes), radars, and other demanding computing, sensing and surveillance electronics. Although boiling process has been studied for over five decades, it has not been yet adapted for widespread deployment. This is mainly due to the lack of a reliable high-performance boiling surface with exceptional heat dissipation potential. Boiling heat transfer is fundamentally limited by CHF (Critical Heat Flux), which is the maximum heat flux a given boiling surface can dissipate. At this point, a vapor layer covers the boiling surface causing surface temperature overshoot with a potential catastrophic failure. Deploying various active and passive methods, researchers have proposed different strategies to push further the CHF values, and thus widen the safe operating limits of a system. In this study, we propose a unique, passive surface topology to enhance heat transfer by altering three distinctive surface properties: augmented roughness, out-of-plane capillary wicking and separate liquid vapor pathways.","abstract_html":"Phase-change heat transfer through pool boiling process offers a promising thermal management solution in applications wherein conventional air or single-phase liquid-based cooling methods prove inefficient such as for high-power electronics. Pool boiling process, which utilizes the latent heat of evaporation, provides a robust and efficient way to efficiently dissipate the excessive heat generated in a small footprint area in particular as seen in CPUs (Central Processing Units), GPUs (Graphics Processing Units), LEDs (Light Emitting Diodes), radars, and other demanding computing, sensing and surveillance electronics. Although boiling process has been studied for over five decades, it has not been yet adapted for widespread deployment. This is mainly due to the lack of a reliable high-performance boiling surface with exceptional heat dissipation potential. Boiling heat transfer is fundamentally limited by CHF (Critical Heat Flux), which is the maximum heat flux a given boiling surface can dissipate. At this point, a vapor layer covers the boiling surface causing surface temperature overshoot with a potential catastrophic failure. Deploying various active and passive methods, researchers have proposed different strategies to push further the CHF values, and thus widen the safe operating limits of a system. In this study, we propose a unique, passive surface topology to enhance heat transfer by altering three distinctive surface properties: augmented roughness, out-of-plane capillary wicking and separate liquid vapor pathways.","abstract_has_math":false,"creators":["Agarwal, Chetan"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Mechanical Engineering-Engineering Mechanics","degree_department":null,"school":null,"contributors":["Sajjad Bigham"],"advisors":[],"committee_chairs":[],"committee_members":["Kazuya Tajiri","Song-Lin Yang"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:49Z","subjects":["Electronic Cooling","Capillary Wicking","Pool Boiling Enhancement","Critical heat flux","Copper Mesh","Porous copper surface","Heat Transfer, Combustion","Manufacturing"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/862"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/862","href":"https://digitalcommons.mtu.edu/etdr/862","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/862","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/862","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-1981","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sajjad Bigham"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kazuya Tajiri","Song-Lin Yang"]},{"key":"dc:creator","label":"Author","values":["Agarwal, Chetan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering-Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electronic Cooling","Capillary Wicking","Pool Boiling Enhancement","Critical heat flux","Copper Mesh","Porous copper surface","Heat Transfer, Combustion","Manufacturing"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/862","https://digitalcommons.mtu.edu/etdr/862"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Phase-change heat transfer through pool boiling process offers a promising thermal management solution in applications wherein conventional air or single-phase liquid-based cooling methods prove inefficient such as for high-power electronics. Pool boiling process, which utilizes the latent heat of evaporation, provides a robust and efficient way to efficiently dissipate the excessive heat generated in a small footprint area in particular as seen in CPUs (Central Processing Units), GPUs (Graphics Processing Units), LEDs (Light Emitting Diodes), radars, and other demanding computing, sensing and surveillance electronics. Although boiling process has been studied for over five decades, it has not been yet adapted for widespread deployment. This is mainly due to the lack of a reliable high-performance boiling surface with exceptional heat dissipation potential. Boiling heat transfer is fundamentally limited by CHF (Critical Heat Flux), which is the maximum heat flux a given boiling surface can dissipate. At this point, a vapor layer covers the boiling surface causing surface temperature overshoot with a potential catastrophic failure. Deploying various active and passive methods, researchers have proposed different strategies to push further the CHF values, and thus widen the safe operating limits of a system. In this study, we propose a unique, passive surface topology to enhance heat transfer by altering three distinctive surface properties: augmented roughness, out-of-plane capillary wicking and separate liquid vapor pathways."]},{"key":"dc:title","label":"Title","values":["MULTI-SCALE, CAPILLARY ASSISTED COPPER SURFACES FOR ENHANCED POOL BOILING HEAT TRANSFER PROCESSES"]}]}],"canonical_facts":{"dc:contributor":["Sajjad Bigham"],"dc:contributor.committeemember":["Kazuya Tajiri","Song-Lin Yang"],"dc:creator":["Agarwal, Chetan"],"dc:date.available":["2020-06-09T07:00:00Z"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["Phase-change heat transfer through pool boiling process offers a promising thermal management solution in applications wherein conventional air or single-phase liquid-based cooling methods prove inefficient such as for high-power electronics. Pool boiling process, which utilizes the latent heat of evaporation, provides a robust and efficient way to efficiently dissipate the excessive heat generated in a small footprint area in particular as seen in CPUs (Central Processing Units), GPUs (Graphics Processing Units), LEDs (Light Emitting Diodes), radars, and other demanding computing, sensing and surveillance electronics. Although boiling process has been studied for over five decades, it has not been yet adapted for widespread deployment. This is mainly due to the lack of a reliable high-performance boiling surface with exceptional heat dissipation potential. Boiling heat transfer is fundamentally limited by CHF (Critical Heat Flux), which is the maximum heat flux a given boiling surface can dissipate. At this point, a vapor layer covers the boiling surface causing surface temperature overshoot with a potential catastrophic failure. Deploying various active and passive methods, researchers have proposed different strategies to push further the CHF values, and thus widen the safe operating limits of a system. In this study, we propose a unique, passive surface topology to enhance heat transfer by altering three distinctive surface properties: augmented roughness, out-of-plane capillary wicking and separate liquid vapor pathways."],"dc:identifier":["10.37099/mtu.dc.etdr/862","https://digitalcommons.mtu.edu/etdr/862"],"dc:subject":["Electronic Cooling","Capillary Wicking","Pool Boiling Enhancement","Critical heat flux","Copper Mesh","Porous copper surface","Heat Transfer, Combustion","Manufacturing"],"dc:title":["MULTI-SCALE, CAPILLARY ASSISTED COPPER SURFACES FOR ENHANCED POOL BOILING HEAT TRANSFER PROCESSES"],"thesis:degree_discipline":["Department of Mechanical Engineering-Engineering Mechanics"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:17:49Z"}