{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-2027"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-2027","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"MAGNETOSTRICTIVE BONE FIXATION DEVICE FOR CONTROLLING LOCAL MECHANICAL STIMULI TO BONE FRACTURE SITES","abstract":"Several studies have shown the impact of mechanical environments on fracture healing. Studies on the low magnitude, high frequency (LMHF) mechanical stimulations (tens of micro-strains and tens of Hz) have demonstrated improved bone regeneration, especially for bone fractures that do not heal properly and developed into delayed unions or non-unions. This type of treatment is often provided as whole-body vibrations with the patient standing on a vibrating platform. While several studies have shown the useful application of LMHF mechanical stimuli in improving bone density but currently available technologies have limited application in fractured bones. The goal of this project is to develop a bone fracture fixation device that utilizes an integrated actuator based on a magnetostrictive material which changes in physical dimension from tens of nanometers to a few microns depending on the strength of an externally applied magnetic field. The strain produced by the magnetostrictive actuator transferred through the fracture fixation device acts directly on the fracture defect region, resulting in localized loading. The electromagnetic driving system for the magnetostrictive actuator remains outside the body and produces wireless mechanical actuations. This externally controlled mechanical loading can help in investigating the effect of various types of mechanical stimulus on bone healing. Specifically, this project will focus on osteogenesis in critically-sized segmental bone defects in rats, an established animal model in bone regeneration studies. The focus of this project is to (1) develop a device that can generate variable mechanical loads on segmental bone defects in rats and (2) to conduct an in vivo study assessing the effects of augmented mechanical loading on osteogenesis.","abstract_html":"Several studies have shown the impact of mechanical environments on fracture healing. Studies on the low magnitude, high frequency (LMHF) mechanical stimulations (tens of micro-strains and tens of Hz) have demonstrated improved bone regeneration, especially for bone fractures that do not heal properly and developed into delayed unions or non-unions. This type of treatment is often provided as whole-body vibrations with the patient standing on a vibrating platform. While several studies have shown the useful application of LMHF mechanical stimuli in improving bone density but currently available technologies have limited application in fractured bones. The goal of this project is to develop a bone fracture fixation device that utilizes an integrated actuator based on a magnetostrictive material which changes in physical dimension from tens of nanometers to a few microns depending on the strength of an externally applied magnetic field. The strain produced by the magnetostrictive actuator transferred through the fracture fixation device acts directly on the fracture defect region, resulting in localized loading. The electromagnetic driving system for the magnetostrictive actuator remains outside the body and produces wireless mechanical actuations. This externally controlled mechanical loading can help in investigating the effect of various types of mechanical stimulus on bone healing. Specifically, this project will focus on osteogenesis in critically-sized segmental bone defects in rats, an established animal model in bone regeneration studies. The focus of this project is to (1) develop a device that can generate variable mechanical loads on segmental bone defects in rats and (2) to conduct an in vivo study assessing the effects of augmented mechanical loading on osteogenesis.","abstract_has_math":false,"creators":["Karipott, Salil Sidharthan"],"institution":null,"degree_name":"Doctor of Philosophy in Biomedical Engineering (PhD)","degree_level":"Campus Access Dissertation","degree_discipline":"Department of Biomedical Engineering","degree_department":null,"school":null,"contributors":["Keat Ghee Ong"],"advisors":[],"committee_chairs":[],"committee_members":["JIngfeng Jiang","Smitha Rao","Yongmei Jin"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:49Z","subjects":["Biomechanics and Biotransport","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Other Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/907"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/907","href":"https://digitalcommons.mtu.edu/etdr/907","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/907","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/907","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-2027","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Keat Ghee Ong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["JIngfeng Jiang","Smitha Rao","Yongmei Jin"]},{"key":"dc:creator","label":"Author","values":["Karipott, Salil Sidharthan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy in Biomedical Engineering (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics and Biotransport","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Other Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/907","https://digitalcommons.mtu.edu/etdr/907"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Several studies have shown the impact of mechanical environments on fracture healing. Studies on the low magnitude, high frequency (LMHF) mechanical stimulations (tens of micro-strains and tens of Hz) have demonstrated improved bone regeneration, especially for bone fractures that do not heal properly and developed into delayed unions or non-unions. This type of treatment is often provided as whole-body vibrations with the patient standing on a vibrating platform. While several studies have shown the useful application of LMHF mechanical stimuli in improving bone density but currently available technologies have limited application in fractured bones. The goal of this project is to develop a bone fracture fixation device that utilizes an integrated actuator based on a magnetostrictive material which changes in physical dimension from tens of nanometers to a few microns depending on the strength of an externally applied magnetic field. The strain produced by the magnetostrictive actuator transferred through the fracture fixation device acts directly on the fracture defect region, resulting in localized loading. The electromagnetic driving system for the magnetostrictive actuator remains outside the body and produces wireless mechanical actuations. This externally controlled mechanical loading can help in investigating the effect of various types of mechanical stimulus on bone healing. Specifically, this project will focus on osteogenesis in critically-sized segmental bone defects in rats, an established animal model in bone regeneration studies. The focus of this project is to (1) develop a device that can generate variable mechanical loads on segmental bone defects in rats and (2) to conduct an in vivo study assessing the effects of augmented mechanical loading on osteogenesis."]},{"key":"dc:title","label":"Title","values":["MAGNETOSTRICTIVE BONE FIXATION DEVICE FOR CONTROLLING LOCAL MECHANICAL STIMULI TO BONE FRACTURE SITES"]}]}],"canonical_facts":{"dc:contributor":["Keat Ghee Ong"],"dc:contributor.committeemember":["JIngfeng Jiang","Smitha Rao","Yongmei Jin"],"dc:creator":["Karipott, Salil Sidharthan"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["Several studies have shown the impact of mechanical environments on fracture healing. Studies on the low magnitude, high frequency (LMHF) mechanical stimulations (tens of micro-strains and tens of Hz) have demonstrated improved bone regeneration, especially for bone fractures that do not heal properly and developed into delayed unions or non-unions. This type of treatment is often provided as whole-body vibrations with the patient standing on a vibrating platform. While several studies have shown the useful application of LMHF mechanical stimuli in improving bone density but currently available technologies have limited application in fractured bones. The goal of this project is to develop a bone fracture fixation device that utilizes an integrated actuator based on a magnetostrictive material which changes in physical dimension from tens of nanometers to a few microns depending on the strength of an externally applied magnetic field. The strain produced by the magnetostrictive actuator transferred through the fracture fixation device acts directly on the fracture defect region, resulting in localized loading. The electromagnetic driving system for the magnetostrictive actuator remains outside the body and produces wireless mechanical actuations. This externally controlled mechanical loading can help in investigating the effect of various types of mechanical stimulus on bone healing. Specifically, this project will focus on osteogenesis in critically-sized segmental bone defects in rats, an established animal model in bone regeneration studies. The focus of this project is to (1) develop a device that can generate variable mechanical loads on segmental bone defects in rats and (2) to conduct an in vivo study assessing the effects of augmented mechanical loading on osteogenesis."],"dc:identifier":["10.37099/mtu.dc.etdr/907","https://digitalcommons.mtu.edu/etdr/907"],"dc:subject":["Biomechanics and Biotransport","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Other Biomedical Engineering and Bioengineering"],"dc:title":["MAGNETOSTRICTIVE BONE FIXATION DEVICE FOR CONTROLLING LOCAL MECHANICAL STIMULI TO BONE FRACTURE SITES"],"thesis:degree_discipline":["Department of Biomedical Engineering"],"thesis:degree_level":["Campus Access Dissertation"],"thesis:degree_name":["Doctor of Philosophy in Biomedical Engineering (PhD)"]},"updated_at":"2026-11-19T08:17:49Z"}