{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-2151"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-2151","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"Measurement of current distribution in the land channel direction of a proton exchange membrane fuel cell","abstract":"A fully functional proton exchange membrane fuel cell with single land channel geometry on the cathode and segmented anode current collector with 9 mm2 active area with a 350μm spatial resolution was utilized to measure the local current distribution in the land channel direction. A distinguished printed circuit board approach was used for the data acquisition to adapt to any flow field design. Performance of this segmented cell was examined at dry, wet and moderate humidity settings to study the water transport phenomenon in the PEMFC. In the dry condition at 60 ͦ C with 0% relative humidity, the non-uniform water production and dehydrated membrane revealed high current localization under the land region. Conversely, in the wet condition at 60 ͦ C with 80% relative humidity, due to the severe flooding in the catalyst layer resulted in very small limiting current density under the channel region. Individual segment performance analysis for the moderate settings at 60 ͦ C with 60% relative humidity displayed the uniform current distribution at higher cell potential whereas irregular local current generation at low cell voltages due to higher water accumulation under the land region.","abstract_html":"A fully functional proton exchange membrane fuel cell with single land channel geometry on the cathode and segmented anode current collector with 9 mm2 active area with a 350μm spatial resolution was utilized to measure the local current distribution in the land channel direction. A distinguished printed circuit board approach was used for the data acquisition to adapt to any flow field design. Performance of this segmented cell was examined at dry, wet and moderate humidity settings to study the water transport phenomenon in the PEMFC. In the dry condition at 60 ͦ C with 0% relative humidity, the non-uniform water production and dehydrated membrane revealed high current localization under the land region. Conversely, in the wet condition at 60 ͦ C with 80% relative humidity, due to the severe flooding in the catalyst layer resulted in very small limiting current density under the channel region. Individual segment performance analysis for the moderate settings at 60 ͦ C with 60% relative humidity displayed the uniform current distribution at higher cell potential whereas irregular local current generation at low cell voltages due to higher water accumulation under the land region.","abstract_has_math":false,"creators":["Kulkarni, Chinmay"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Report","degree_discipline":"Department of Mechanical Engineering-Engineering Mechanics","degree_department":null,"school":null,"contributors":["Kazuya Tajiri"],"advisors":[],"committee_chairs":[],"committee_members":["Jeffrey Allen","Radheshyam Tewari"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:17:59Z","subjects":["Fuel cell","Proton Exchange membrane","current distribution","water distribution","segmented","land channel","Automotive Engineering","Energy Systems","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/976"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/976","href":"https://digitalcommons.mtu.edu/etdr/976","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/976","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/976","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-2151","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kazuya Tajiri"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jeffrey Allen","Radheshyam Tewari"]},{"key":"dc:creator","label":"Author","values":["Kulkarni, Chinmay"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering-Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fuel cell","Proton Exchange membrane","current distribution","water distribution","segmented","land channel","Automotive Engineering","Energy Systems","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/976","https://digitalcommons.mtu.edu/etdr/976"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A fully functional proton exchange membrane fuel cell with single land channel geometry on the cathode and segmented anode current collector with 9 mm2 active area with a 350μm spatial resolution was utilized to measure the local current distribution in the land channel direction. A distinguished printed circuit board approach was used for the data acquisition to adapt to any flow field design. Performance of this segmented cell was examined at dry, wet and moderate humidity settings to study the water transport phenomenon in the PEMFC. In the dry condition at 60 ͦ C with 0% relative humidity, the non-uniform water production and dehydrated membrane revealed high current localization under the land region. Conversely, in the wet condition at 60 ͦ C with 80% relative humidity, due to the severe flooding in the catalyst layer resulted in very small limiting current density under the channel region. Individual segment performance analysis for the moderate settings at 60 ͦ C with 60% relative humidity displayed the uniform current distribution at higher cell potential whereas irregular local current generation at low cell voltages due to higher water accumulation under the land region."]},{"key":"dc:title","label":"Title","values":["Measurement of current distribution in the land channel direction of a proton exchange membrane fuel cell"]}]}],"canonical_facts":{"dc:contributor":["Kazuya Tajiri"],"dc:contributor.committeemember":["Jeffrey Allen","Radheshyam Tewari"],"dc:creator":["Kulkarni, Chinmay"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["A fully functional proton exchange membrane fuel cell with single land channel geometry on the cathode and segmented anode current collector with 9 mm2 active area with a 350μm spatial resolution was utilized to measure the local current distribution in the land channel direction. A distinguished printed circuit board approach was used for the data acquisition to adapt to any flow field design. Performance of this segmented cell was examined at dry, wet and moderate humidity settings to study the water transport phenomenon in the PEMFC. In the dry condition at 60 ͦ C with 0% relative humidity, the non-uniform water production and dehydrated membrane revealed high current localization under the land region. Conversely, in the wet condition at 60 ͦ C with 80% relative humidity, due to the severe flooding in the catalyst layer resulted in very small limiting current density under the channel region. Individual segment performance analysis for the moderate settings at 60 ͦ C with 60% relative humidity displayed the uniform current distribution at higher cell potential whereas irregular local current generation at low cell voltages due to higher water accumulation under the land region."],"dc:identifier":["10.37099/mtu.dc.etdr/976","https://digitalcommons.mtu.edu/etdr/976"],"dc:subject":["Fuel cell","Proton Exchange membrane","current distribution","water distribution","segmented","land channel","Automotive Engineering","Energy Systems","Mechanical Engineering"],"dc:title":["Measurement of current distribution in the land channel direction of a proton exchange membrane fuel cell"],"thesis:degree_discipline":["Department of Mechanical Engineering-Engineering Mechanics"],"thesis:degree_level":["Open Access Master's Report"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:17:59Z"}