{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-2276"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-2276","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"GENERATION OF PREMIX LAMINAR FLAME SPEED LIBRARY","abstract":"The Laminar flame speed is an essential parameter in measuring turbulent premixed combustion applied in Spark ignition engines. Instead of using power-law correlations, which is valid only for particular ranges, the procedure for generating a premixed laminar flame speed library is defined using MTU – Master mechanism for a wide range of charge mixture conditions inside an engine combustion chamber: Temperature (300 – 700 K), Pressure (1 – 70 bar) and reactant mixture composition of equivalence ratio (0.4 – 2.0) Laminar flame speed library is generated for methane. The mechanism's performance was improved by adjusting the pre-exponential factor of the most sensitive reactions found from the sensitivity analysis to match the simulation results with experimental data in the literature. It is observed that the sensitivity order of reactions changes for different operating conditions, except that H+O2=O+OH, is the most sensitive reaction.","abstract_html":"The Laminar flame speed is an essential parameter in measuring turbulent premixed combustion applied in Spark ignition engines. Instead of using power-law correlations, which is valid only for particular ranges, the procedure for generating a premixed laminar flame speed library is defined using MTU – Master mechanism for a wide range of charge mixture conditions inside an engine combustion chamber: Temperature (300 – 700 K), Pressure (1 – 70 bar) and reactant mixture composition of equivalence ratio (0.4 – 2.0) Laminar flame speed library is generated for methane. The mechanism&#x27;s performance was improved by adjusting the pre-exponential factor of the most sensitive reactions found from the sensitivity analysis to match the simulation results with experimental data in the literature. It is observed that the sensitivity order of reactions changes for different operating conditions, except that H+O2=O+OH, is the most sensitive reaction.","abstract_has_math":false,"creators":["Kumar, Sai Prashanth"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Mechanical Engineering-Engineering Mechanics","degree_department":null,"school":null,"contributors":["Youngchul Ra"],"advisors":[],"committee_chairs":[],"committee_members":["Chunpei Cai","Hassan Masoud"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:18:18Z","subjects":["Laminar flame speed","MTU-Master mechanism","Engine combustion CFD","Sensitivity analysis for laminar flame speed","Laminar flame speed library","Computer-Aided Engineering and Design","Energy Systems","Heat Transfer, Combustion","Propulsion and Power"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/1106"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/1106","href":"https://digitalcommons.mtu.edu/etdr/1106","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/1106","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/1106","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-2276","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Youngchul Ra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Chunpei Cai","Hassan Masoud"]},{"key":"dc:creator","label":"Author","values":["Kumar, Sai Prashanth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-12-07T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering-Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Laminar flame speed","MTU-Master mechanism","Engine combustion CFD","Sensitivity analysis for laminar flame speed","Laminar flame speed library","Computer-Aided Engineering and Design","Energy Systems","Heat Transfer, Combustion","Propulsion and Power"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/1106","https://digitalcommons.mtu.edu/etdr/1106"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Laminar flame speed is an essential parameter in measuring turbulent premixed combustion applied in Spark ignition engines. Instead of using power-law correlations, which is valid only for particular ranges, the procedure for generating a premixed laminar flame speed library is defined using MTU – Master mechanism for a wide range of charge mixture conditions inside an engine combustion chamber: Temperature (300 – 700 K), Pressure (1 – 70 bar) and reactant mixture composition of equivalence ratio (0.4 – 2.0) Laminar flame speed library is generated for methane. The mechanism's performance was improved by adjusting the pre-exponential factor of the most sensitive reactions found from the sensitivity analysis to match the simulation results with experimental data in the literature. It is observed that the sensitivity order of reactions changes for different operating conditions, except that H+O2=O+OH, is the most sensitive reaction."]},{"key":"dc:title","label":"Title","values":["GENERATION OF PREMIX LAMINAR FLAME SPEED LIBRARY"]}]}],"canonical_facts":{"dc:contributor":["Youngchul Ra"],"dc:contributor.committeemember":["Chunpei Cai","Hassan Masoud"],"dc:creator":["Kumar, Sai Prashanth"],"dc:date.available":["2021-12-07T08:00:00Z"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["The Laminar flame speed is an essential parameter in measuring turbulent premixed combustion applied in Spark ignition engines. Instead of using power-law correlations, which is valid only for particular ranges, the procedure for generating a premixed laminar flame speed library is defined using MTU – Master mechanism for a wide range of charge mixture conditions inside an engine combustion chamber: Temperature (300 – 700 K), Pressure (1 – 70 bar) and reactant mixture composition of equivalence ratio (0.4 – 2.0) Laminar flame speed library is generated for methane. The mechanism's performance was improved by adjusting the pre-exponential factor of the most sensitive reactions found from the sensitivity analysis to match the simulation results with experimental data in the literature. It is observed that the sensitivity order of reactions changes for different operating conditions, except that H+O2=O+OH, is the most sensitive reaction."],"dc:identifier":["10.37099/mtu.dc.etdr/1106","https://digitalcommons.mtu.edu/etdr/1106"],"dc:subject":["Laminar flame speed","MTU-Master mechanism","Engine combustion CFD","Sensitivity analysis for laminar flame speed","Laminar flame speed library","Computer-Aided Engineering and Design","Energy Systems","Heat Transfer, Combustion","Propulsion and Power"],"dc:title":["GENERATION OF PREMIX LAMINAR FLAME SPEED LIBRARY"],"thesis:degree_discipline":["Department of Mechanical Engineering-Engineering Mechanics"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:18:18Z"}