{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-2997"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-2997","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"COMPREHENSIVE REVIEW AND DEVELOPMENT OF A HIGH-PRESSURE HYDRAULIC IMPEDANCE TUBE FOR VIBROACOUSTIC ATTENUATOR CHARACTERIZATION","abstract":"This research establishes a versatile test bench for characterizing hydraulic vibroacoustic attenuators. The primary evaluation metric is the transfer matrix, determined experimentally, with an emphasis on key properties such as transmission loss. To ensure accuracy and broad applicability, the methodology is based on industry-standard techniques for determining the transfer matrix. A comprehensive literature review consolidates existing approaches for hydraulic attenuator characterization. The test bench features a hydraulic impedance tube equipped with eight dynamic pressure transducer (DPT) taps strategically positioned before and after the sample interface. This setup accommodates arbitrary samples terminated with standard hydraulic fittings. Using ASTM E2611, the transfer matrix of the sample is estimated, allowing a reliable and repeatable characterization of the attenuation properties. These results provide critical insights for hydraulic circuit designers across diverse industries, supporting the development and optimization of vibroacoustic attenuators.","abstract_html":"This research establishes a versatile test bench for characterizing hydraulic vibroacoustic attenuators. The primary evaluation metric is the transfer matrix, determined experimentally, with an emphasis on key properties such as transmission loss. To ensure accuracy and broad applicability, the methodology is based on industry-standard techniques for determining the transfer matrix. A comprehensive literature review consolidates existing approaches for hydraulic attenuator characterization. The test bench features a hydraulic impedance tube equipped with eight dynamic pressure transducer (DPT) taps strategically positioned before and after the sample interface. This setup accommodates arbitrary samples terminated with standard hydraulic fittings. Using ASTM E2611, the transfer matrix of the sample is estimated, allowing a reliable and repeatable characterization of the attenuation properties. These results provide critical insights for hydraulic circuit designers across diverse industries, supporting the development and optimization of vibroacoustic attenuators.","abstract_has_math":false,"creators":["Beals, Matthew D."],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Vijaya V. N. Sriram Malladi"],"advisors":[],"committee_chairs":[],"committee_members":["James DeClerck","Chad M. Walber"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:19:12Z","subjects":["Vibroacoustics","Impedance Tube","Hydraulic Attenuators","Transmission Loss","Pressure Ripple Generation Methods","Multi-Point Transfer Matrix Estimation","Acoustics, Dynamics, and Controls","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles","Other Aerospace Engineering","Other Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/1815"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/1815","href":"https://digitalcommons.mtu.edu/etdr/1815","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/1815","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/1815","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-2997","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Vijaya V. N. Sriram Malladi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["James DeClerck","Chad M. Walber"]},{"key":"dc:creator","label":"Author","values":["Beals, Matthew D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-02T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Vibroacoustics","Impedance Tube","Hydraulic Attenuators","Transmission Loss","Pressure Ripple Generation Methods","Multi-Point Transfer Matrix Estimation","Acoustics, Dynamics, and Controls","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles","Other Aerospace Engineering","Other Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/1815","https://digitalcommons.mtu.edu/etdr/1815"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research establishes a versatile test bench for characterizing hydraulic vibroacoustic attenuators. The primary evaluation metric is the transfer matrix, determined experimentally, with an emphasis on key properties such as transmission loss. To ensure accuracy and broad applicability, the methodology is based on industry-standard techniques for determining the transfer matrix. A comprehensive literature review consolidates existing approaches for hydraulic attenuator characterization. The test bench features a hydraulic impedance tube equipped with eight dynamic pressure transducer (DPT) taps strategically positioned before and after the sample interface. This setup accommodates arbitrary samples terminated with standard hydraulic fittings. Using ASTM E2611, the transfer matrix of the sample is estimated, allowing a reliable and repeatable characterization of the attenuation properties. These results provide critical insights for hydraulic circuit designers across diverse industries, supporting the development and optimization of vibroacoustic attenuators."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Sorry if this is my second submission! I did not receive a confirmation upon my last attempt</p>"]},{"key":"dc:title","label":"Title","values":["COMPREHENSIVE REVIEW AND DEVELOPMENT OF A HIGH-PRESSURE HYDRAULIC IMPEDANCE TUBE FOR VIBROACOUSTIC ATTENUATOR CHARACTERIZATION"]}]}],"canonical_facts":{"dc:contributor":["Vijaya V. N. Sriram Malladi"],"dc:contributor.committeemember":["James DeClerck","Chad M. Walber"],"dc:creator":["Beals, Matthew D."],"dc:date.available":["2025-06-02T07:00:00Z"],"dc:date.created":["2024-01-01T08:00:00Z"],"dc:description.abstract":["This research establishes a versatile test bench for characterizing hydraulic vibroacoustic attenuators. The primary evaluation metric is the transfer matrix, determined experimentally, with an emphasis on key properties such as transmission loss. To ensure accuracy and broad applicability, the methodology is based on industry-standard techniques for determining the transfer matrix. A comprehensive literature review consolidates existing approaches for hydraulic attenuator characterization. The test bench features a hydraulic impedance tube equipped with eight dynamic pressure transducer (DPT) taps strategically positioned before and after the sample interface. This setup accommodates arbitrary samples terminated with standard hydraulic fittings. Using ASTM E2611, the transfer matrix of the sample is estimated, allowing a reliable and repeatable characterization of the attenuation properties. These results provide critical insights for hydraulic circuit designers across diverse industries, supporting the development and optimization of vibroacoustic attenuators."],"dc:description.note":["<p>Sorry if this is my second submission! I did not receive a confirmation upon my last attempt</p>"],"dc:identifier":["10.37099/mtu.dc.etdr/1815","https://digitalcommons.mtu.edu/etdr/1815"],"dc:subject":["Vibroacoustics","Impedance Tube","Hydraulic Attenuators","Transmission Loss","Pressure Ripple Generation Methods","Multi-Point Transfer Matrix Estimation","Acoustics, Dynamics, and Controls","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles","Other Aerospace Engineering","Other Mechanical Engineering"],"dc:title":["COMPREHENSIVE REVIEW AND DEVELOPMENT OF A HIGH-PRESSURE HYDRAULIC IMPEDANCE TUBE FOR VIBROACOUSTIC ATTENUATOR CHARACTERIZATION"],"thesis:degree_discipline":["Department of Mechanical and Aerospace Engineering"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:19:12Z"}