{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-3042"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-3042","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"NEAR-INFRARED HEMICYANINE AND BODIPY SENSORS FOR MONITORING MITOCHONDRIAL VISCOSITY IN LIVE CANCER CELLS, DROSOPHILA MELANOGASTER LARVAE, AND ADPKD KIDNEY TISSUE","abstract":"Two near-infrared fluorescent sensors, sensor A and sensor B, were synthesized and characterized. Sensor A was a hemicyanine derived structure, and sensor B was a BODIPY derived sensor. The sensors were tested to measure their ability to monitor viscosity, and sensor A was used to monitor viscosity in live cells. Both sensors were found to be effective in monitoring the viscosity level through optical measurements with glycerol. Sensor A was found to be successful in monitoring mitochondrial viscosity in HeLa MBA-MD-453 and MDA-MB-231 cell lines. It was also successful in monitoring viscosity in Drosophila melanogaster larvae as well as in ADPKD affected mice kidney tissue. In all of these scenarios, the fluorescent intensity increased with viscosity. Sensor A has provided significant evidence that it would be a useful tool in monitoring mitochondrial viscosity in a variety of cellular conditions.","abstract_html":"Two near-infrared fluorescent sensors, sensor A and sensor B, were synthesized and characterized. Sensor A was a hemicyanine derived structure, and sensor B was a BODIPY derived sensor. The sensors were tested to measure their ability to monitor viscosity, and sensor A was used to monitor viscosity in live cells. Both sensors were found to be effective in monitoring the viscosity level through optical measurements with glycerol. Sensor A was found to be successful in monitoring mitochondrial viscosity in HeLa MBA-MD-453 and MDA-MB-231 cell lines. It was also successful in monitoring viscosity in Drosophila melanogaster larvae as well as in ADPKD affected mice kidney tissue. In all of these scenarios, the fluorescent intensity increased with viscosity. Sensor A has provided significant evidence that it would be a useful tool in monitoring mitochondrial viscosity in a variety of cellular conditions.","abstract_has_math":false,"creators":["Peters, Joseph"],"institution":null,"degree_name":"Master of Science in Chemistry (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Chemistry","degree_department":null,"school":null,"contributors":["Haiying Liu"],"advisors":[],"committee_chairs":[],"committee_members":["Lanrong Bi","Tarun Dam","Momoko Tajiri"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:19:20Z","subjects":["Fluorescence","Probes","Viscosity","Mitochondria","Hemicyanine","BODIPY","Biochemistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/1902"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/1902","href":"https://digitalcommons.mtu.edu/etdr/1902","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/1902","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/1902","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-3042","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Haiying Liu"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lanrong Bi","Tarun Dam","Momoko Tajiri"]},{"key":"dc:creator","label":"Author","values":["Peters, Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-14T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemistry (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluorescence","Probes","Viscosity","Mitochondria","Hemicyanine","BODIPY","Biochemistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/1902","https://digitalcommons.mtu.edu/etdr/1902"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two near-infrared fluorescent sensors, sensor A and sensor B, were synthesized and characterized. Sensor A was a hemicyanine derived structure, and sensor B was a BODIPY derived sensor. The sensors were tested to measure their ability to monitor viscosity, and sensor A was used to monitor viscosity in live cells. Both sensors were found to be effective in monitoring the viscosity level through optical measurements with glycerol. Sensor A was found to be successful in monitoring mitochondrial viscosity in HeLa MBA-MD-453 and MDA-MB-231 cell lines. It was also successful in monitoring viscosity in Drosophila melanogaster larvae as well as in ADPKD affected mice kidney tissue. In all of these scenarios, the fluorescent intensity increased with viscosity. Sensor A has provided significant evidence that it would be a useful tool in monitoring mitochondrial viscosity in a variety of cellular conditions."]},{"key":"dc:title","label":"Title","values":["NEAR-INFRARED HEMICYANINE AND BODIPY SENSORS FOR MONITORING MITOCHONDRIAL VISCOSITY IN LIVE CANCER CELLS, DROSOPHILA MELANOGASTER LARVAE, AND ADPKD KIDNEY TISSUE"]}]}],"canonical_facts":{"dc:contributor":["Haiying Liu"],"dc:contributor.committeemember":["Lanrong Bi","Tarun Dam","Momoko Tajiri"],"dc:creator":["Peters, Joseph"],"dc:date.available":["2025-10-14T07:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Two near-infrared fluorescent sensors, sensor A and sensor B, were synthesized and characterized. Sensor A was a hemicyanine derived structure, and sensor B was a BODIPY derived sensor. The sensors were tested to measure their ability to monitor viscosity, and sensor A was used to monitor viscosity in live cells. Both sensors were found to be effective in monitoring the viscosity level through optical measurements with glycerol. Sensor A was found to be successful in monitoring mitochondrial viscosity in HeLa MBA-MD-453 and MDA-MB-231 cell lines. It was also successful in monitoring viscosity in Drosophila melanogaster larvae as well as in ADPKD affected mice kidney tissue. In all of these scenarios, the fluorescent intensity increased with viscosity. Sensor A has provided significant evidence that it would be a useful tool in monitoring mitochondrial viscosity in a variety of cellular conditions."],"dc:identifier":["10.37099/mtu.dc.etdr/1902","https://digitalcommons.mtu.edu/etdr/1902"],"dc:subject":["Fluorescence","Probes","Viscosity","Mitochondria","Hemicyanine","BODIPY","Biochemistry"],"dc:title":["NEAR-INFRARED HEMICYANINE AND BODIPY SENSORS FOR MONITORING MITOCHONDRIAL VISCOSITY IN LIVE CANCER CELLS, DROSOPHILA MELANOGASTER LARVAE, AND ADPKD KIDNEY TISSUE"],"thesis:degree_discipline":["Department of Chemistry"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Chemistry (MS)"]},"updated_at":"2026-11-19T08:19:20Z"}