{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-3112"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-3112","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"Using Tunable Diode Laser Absorption Spectroscopy to Measure Atmospheric Water Vapor Concentrations","abstract":"Obtaining accurate measurements of water vapor concentrations is essential for understanding many atmospheric phenomena, such as cloud formation and radiative balance. The ability to do so while minimizing direct contact with the system through remote sensing is especially valuable. With this project, we continued the development of a tunable diode laser hygrometer that provides highly accurate, path-integrated measurements of water vapor concentration. This system utilizes a balanced photodiode circuit to eliminate the power ramp intrinsic to the diode laser wavelength tuning process. The results of this laboratory work show excellent agreement between transmission measurements and simulations based on the HIgh-resolution TRANsmission molecular absorption database (HITRAN). The benchtop system characterized and described here will be packaged into a laboratory instrument to be used with MTU’s Pi Cloud Chamber. Upon completion the hygrometer should be widely applicable to many studies in clouds and aerosol research. The ability to use simulation to bypass much of the need for calibration should also allow for rapid deployment.","abstract_html":"Obtaining accurate measurements of water vapor concentrations is essential for understanding many atmospheric phenomena, such as cloud formation and radiative balance. The ability to do so while minimizing direct contact with the system through remote sensing is especially valuable. With this project, we continued the development of a tunable diode laser hygrometer that provides highly accurate, path-integrated measurements of water vapor concentration. This system utilizes a balanced photodiode circuit to eliminate the power ramp intrinsic to the diode laser wavelength tuning process. The results of this laboratory work show excellent agreement between transmission measurements and simulations based on the HIgh-resolution TRANsmission molecular absorption database (HITRAN). The benchtop system characterized and described here will be packaged into a laboratory instrument to be used with MTU’s Pi Cloud Chamber. Upon completion the hygrometer should be widely applicable to many studies in clouds and aerosol research. The ability to use simulation to bypass much of the need for calibration should also allow for rapid deployment.","abstract_has_math":false,"creators":["Koshar, Daniel"],"institution":null,"degree_name":"Master of Science in Applied Physics (MS)","degree_level":"Campus Access Master's Report","degree_discipline":"Department of Physics","degree_department":null,"school":null,"contributors":["Claudio Mazzoleni"],"advisors":[],"committee_chairs":[],"committee_members":["Jacek Borysow","Shawn Brueshaber"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:19:20Z","subjects":["Water Vapor","Atmosphere","Laser","Hygrometry","Absorption","Absorption Spectroscopy","Atmospheric Sciences","Optics","Other Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/1963"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/1963","href":"https://digitalcommons.mtu.edu/etdr/1963","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/1963","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/1963","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-3112","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Claudio Mazzoleni"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jacek Borysow","Shawn Brueshaber"]},{"key":"dc:creator","label":"Author","values":["Koshar, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Campus Access Master's Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Physics (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water Vapor","Atmosphere","Laser","Hygrometry","Absorption","Absorption Spectroscopy","Atmospheric Sciences","Optics","Other Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/1963","https://digitalcommons.mtu.edu/etdr/1963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Obtaining accurate measurements of water vapor concentrations is essential for understanding many atmospheric phenomena, such as cloud formation and radiative balance. The ability to do so while minimizing direct contact with the system through remote sensing is especially valuable. With this project, we continued the development of a tunable diode laser hygrometer that provides highly accurate, path-integrated measurements of water vapor concentration. This system utilizes a balanced photodiode circuit to eliminate the power ramp intrinsic to the diode laser wavelength tuning process. The results of this laboratory work show excellent agreement between transmission measurements and simulations based on the HIgh-resolution TRANsmission molecular absorption database (HITRAN). The benchtop system characterized and described here will be packaged into a laboratory instrument to be used with MTU’s Pi Cloud Chamber. Upon completion the hygrometer should be widely applicable to many studies in clouds and aerosol research. The ability to use simulation to bypass much of the need for calibration should also allow for rapid deployment."]},{"key":"dc:title","label":"Title","values":["Using Tunable Diode Laser Absorption Spectroscopy to Measure Atmospheric Water Vapor Concentrations"]}]}],"canonical_facts":{"dc:contributor":["Claudio Mazzoleni"],"dc:contributor.committeemember":["Jacek Borysow","Shawn Brueshaber"],"dc:creator":["Koshar, Daniel"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Obtaining accurate measurements of water vapor concentrations is essential for understanding many atmospheric phenomena, such as cloud formation and radiative balance. The ability to do so while minimizing direct contact with the system through remote sensing is especially valuable. With this project, we continued the development of a tunable diode laser hygrometer that provides highly accurate, path-integrated measurements of water vapor concentration. This system utilizes a balanced photodiode circuit to eliminate the power ramp intrinsic to the diode laser wavelength tuning process. The results of this laboratory work show excellent agreement between transmission measurements and simulations based on the HIgh-resolution TRANsmission molecular absorption database (HITRAN). The benchtop system characterized and described here will be packaged into a laboratory instrument to be used with MTU’s Pi Cloud Chamber. Upon completion the hygrometer should be widely applicable to many studies in clouds and aerosol research. The ability to use simulation to bypass much of the need for calibration should also allow for rapid deployment."],"dc:identifier":["10.37099/mtu.dc.etdr/1963","https://digitalcommons.mtu.edu/etdr/1963"],"dc:subject":["Water Vapor","Atmosphere","Laser","Hygrometry","Absorption","Absorption Spectroscopy","Atmospheric Sciences","Optics","Other Physics"],"dc:title":["Using Tunable Diode Laser Absorption Spectroscopy to Measure Atmospheric Water Vapor Concentrations"],"thesis:degree_discipline":["Department of Physics"],"thesis:degree_level":["Campus Access Master's Report"],"thesis:degree_name":["Master of Science in Applied Physics (MS)"]},"updated_at":"2026-11-19T08:19:20Z"}