{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-3206"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-3206","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"COMPARISON OF FIXED TILT AND SINGLE AXIS TRACKING SOLAR PHOTOVOLTAICS DURING WINTER","abstract":"As solar projects are built in northern climates, it is necessary to understand how snow cover impacts power generation. While there are validated models that predict snow shedding for fixed tilt projects, there is not one for single axis tracking systems. This report aims to characterize the differences between fixed tilt and single axis tracking systems under the same snow conditions. Generation data was collected over four winter months for fixed tilt and tracking systems at Michigan Technological University. Models were created for both systems using weather information from the site, in which losses were set to zero to create an ideal case. The models were used to calculate snow losses for both systems. For all four months, the tracker generated more power and experienced less snow loss than the fixed tilt system. These findings suggest that the single axis tracker results in more seasonal generation due to improved snow shedding compared to fixed tilt systems.","abstract_html":"As solar projects are built in northern climates, it is necessary to understand how snow cover impacts power generation. While there are validated models that predict snow shedding for fixed tilt projects, there is not one for single axis tracking systems. This report aims to characterize the differences between fixed tilt and single axis tracking systems under the same snow conditions. Generation data was collected over four winter months for fixed tilt and tracking systems at Michigan Technological University. Models were created for both systems using weather information from the site, in which losses were set to zero to create an ideal case. The models were used to calculate snow losses for both systems. For all four months, the tracker generated more power and experienced less snow loss than the fixed tilt system. These findings suggest that the single axis tracker results in more seasonal generation due to improved snow shedding compared to fixed tilt systems.","abstract_has_math":false,"creators":["Bowker, Isobel R."],"institution":null,"degree_name":"Master of Science in Mechanical Engineering (MS)","degree_level":"Open Access Master's Report","degree_discipline":"Department of Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Ana Dyreson"],"advisors":[],"committee_chairs":[],"committee_members":["Ezra Bar-Ziv","Youngchul Ra"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:19:26Z","subjects":["Energy Systems"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/2055"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/2055","href":"https://digitalcommons.mtu.edu/etdr/2055","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/2055","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/2055","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-3206","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ana Dyreson"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ezra Bar-Ziv","Youngchul Ra"]},{"key":"dc:creator","label":"Author","values":["Bowker, Isobel R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy Systems"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/2055","https://digitalcommons.mtu.edu/etdr/2055"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As solar projects are built in northern climates, it is necessary to understand how snow cover impacts power generation. While there are validated models that predict snow shedding for fixed tilt projects, there is not one for single axis tracking systems. This report aims to characterize the differences between fixed tilt and single axis tracking systems under the same snow conditions. Generation data was collected over four winter months for fixed tilt and tracking systems at Michigan Technological University. Models were created for both systems using weather information from the site, in which losses were set to zero to create an ideal case. The models were used to calculate snow losses for both systems. For all four months, the tracker generated more power and experienced less snow loss than the fixed tilt system. These findings suggest that the single axis tracker results in more seasonal generation due to improved snow shedding compared to fixed tilt systems."]},{"key":"dc:title","label":"Title","values":["COMPARISON OF FIXED TILT AND SINGLE AXIS TRACKING SOLAR PHOTOVOLTAICS DURING WINTER"]}]}],"canonical_facts":{"dc:contributor":["Ana Dyreson"],"dc:contributor.committeemember":["Ezra Bar-Ziv","Youngchul Ra"],"dc:creator":["Bowker, Isobel R."],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:description.abstract":["As solar projects are built in northern climates, it is necessary to understand how snow cover impacts power generation. While there are validated models that predict snow shedding for fixed tilt projects, there is not one for single axis tracking systems. This report aims to characterize the differences between fixed tilt and single axis tracking systems under the same snow conditions. Generation data was collected over four winter months for fixed tilt and tracking systems at Michigan Technological University. Models were created for both systems using weather information from the site, in which losses were set to zero to create an ideal case. The models were used to calculate snow losses for both systems. For all four months, the tracker generated more power and experienced less snow loss than the fixed tilt system. These findings suggest that the single axis tracker results in more seasonal generation due to improved snow shedding compared to fixed tilt systems."],"dc:identifier":["10.37099/mtu.dc.etdr/2055","https://digitalcommons.mtu.edu/etdr/2055"],"dc:subject":["Energy Systems"],"dc:title":["COMPARISON OF FIXED TILT AND SINGLE AXIS TRACKING SOLAR PHOTOVOLTAICS DURING WINTER"],"thesis:degree_discipline":["Department of Mechanical and Aerospace Engineering"],"thesis:degree_level":["Open Access Master's Report"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T08:19:26Z"}