{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etdr-3289"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etdr-3289","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"DESIGN AND VALIDATION OF A LOW-COST WEARABLE ELECTROMYOGRAPHY (EMG) SYSTEM FOR MONITORING EXERCISE-INDUCED CHANGES IN MUSCLE ACTIVITY","abstract":"Wearable technologies have expanded opportunities for monitoring athletic performance, but many existing systems remain costly and confined to laboratory or medical settings. This thesis presents the design, development, and evaluation of a low-cost, wearable EMG platform for monitoring neuromuscular activity during exercise. A wireless device incorporating a surface EMG sensor, an ESP32 microcontroller, and Wi-Fi transmission was developed to acquire muscle activation data. Signal processing techniques, including filtering, root-mean-square (RMS), mean frequency (MNF), and median frequency (MDF) analyses, were used to evaluate changes in muscle activation. Experimental testing demonstrated reliable wireless data acquisition and successful capture of physiological changes before and after low-intensity exercise. The proposed system provides an accessible platform for wearable muscle monitoring and establishes a foundation for future research in athletic performance assessment, fatigue detection, and injury prevention.","abstract_html":"Wearable technologies have expanded opportunities for monitoring athletic performance, but many existing systems remain costly and confined to laboratory or medical settings. This thesis presents the design, development, and evaluation of a low-cost, wearable EMG platform for monitoring neuromuscular activity during exercise. A wireless device incorporating a surface EMG sensor, an ESP32 microcontroller, and Wi-Fi transmission was developed to acquire muscle activation data. Signal processing techniques, including filtering, root-mean-square (RMS), mean frequency (MNF), and median frequency (MDF) analyses, were used to evaluate changes in muscle activation. Experimental testing demonstrated reliable wireless data acquisition and successful capture of physiological changes before and after low-intensity exercise. The proposed system provides an accessible platform for wearable muscle monitoring and establishes a foundation for future research in athletic performance assessment, fatigue detection, and injury prevention.","abstract_has_math":false,"creators":["Halverson, Ingrid E."],"institution":null,"degree_name":"Master of Science in Electrical and Computer Engineering (MS)","degree_level":"Open Access Master's Thesis","degree_discipline":"Department of Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Jin W. Choi","Edward F. Austin, Jr."],"advisors":[],"committee_chairs":[],"committee_members":["Tan Chen"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:19:32Z","subjects":["electromyography (EMG)","wearable sensors","athletic performance monitoring","muscle fatigue","signal processing","photoplethysmography (PPG)","Biomedical"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etdr/2146"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etdr/2146","href":"https://digitalcommons.mtu.edu/etdr/2146","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etdr/2146","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etdr/2146","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetdr-3289","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jin W. Choi","Edward F. Austin, Jr."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Tan Chen"]},{"key":"dc:creator","label":"Author","values":["Halverson, Ingrid E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Master's Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical and Computer Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electromyography (EMG)","wearable sensors","athletic performance monitoring","muscle fatigue","signal processing","photoplethysmography (PPG)","Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etdr/2146","https://digitalcommons.mtu.edu/etdr/2146"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Wearable technologies have expanded opportunities for monitoring athletic performance, but many existing systems remain costly and confined to laboratory or medical settings. This thesis presents the design, development, and evaluation of a low-cost, wearable EMG platform for monitoring neuromuscular activity during exercise. A wireless device incorporating a surface EMG sensor, an ESP32 microcontroller, and Wi-Fi transmission was developed to acquire muscle activation data. Signal processing techniques, including filtering, root-mean-square (RMS), mean frequency (MNF), and median frequency (MDF) analyses, were used to evaluate changes in muscle activation. Experimental testing demonstrated reliable wireless data acquisition and successful capture of physiological changes before and after low-intensity exercise. The proposed system provides an accessible platform for wearable muscle monitoring and establishes a foundation for future research in athletic performance assessment, fatigue detection, and injury prevention."]},{"key":"dc:title","label":"Title","values":["DESIGN AND VALIDATION OF A LOW-COST WEARABLE ELECTROMYOGRAPHY (EMG) SYSTEM FOR MONITORING EXERCISE-INDUCED CHANGES IN MUSCLE ACTIVITY"]}]}],"canonical_facts":{"dc:contributor":["Jin W. Choi","Edward F. Austin, Jr."],"dc:contributor.committeemember":["Tan Chen"],"dc:creator":["Halverson, Ingrid E."],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:description.abstract":["Wearable technologies have expanded opportunities for monitoring athletic performance, but many existing systems remain costly and confined to laboratory or medical settings. This thesis presents the design, development, and evaluation of a low-cost, wearable EMG platform for monitoring neuromuscular activity during exercise. A wireless device incorporating a surface EMG sensor, an ESP32 microcontroller, and Wi-Fi transmission was developed to acquire muscle activation data. Signal processing techniques, including filtering, root-mean-square (RMS), mean frequency (MNF), and median frequency (MDF) analyses, were used to evaluate changes in muscle activation. Experimental testing demonstrated reliable wireless data acquisition and successful capture of physiological changes before and after low-intensity exercise. The proposed system provides an accessible platform for wearable muscle monitoring and establishes a foundation for future research in athletic performance assessment, fatigue detection, and injury prevention."],"dc:identifier":["10.37099/mtu.dc.etdr/2146","https://digitalcommons.mtu.edu/etdr/2146"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["electromyography (EMG)","wearable sensors","athletic performance monitoring","muscle fatigue","signal processing","photoplethysmography (PPG)","Biomedical"],"dc:title":["DESIGN AND VALIDATION OF A LOW-COST WEARABLE ELECTROMYOGRAPHY (EMG) SYSTEM FOR MONITORING EXERCISE-INDUCED CHANGES IN MUSCLE ACTIVITY"],"thesis:degree_discipline":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Open Access Master's Thesis"],"thesis:degree_name":["Master of Science in Electrical and Computer Engineering (MS)"]},"updated_at":"2026-11-19T08:19:32Z"}