{"id":{"repo_id":"mtu","oai_identifier":"oai:digitalcommons.mtu.edu:etds-1815"},"canonical_url":"https://search.ndltd.org/etd/mtu/oai:digitalcommons.mtu.edu:etds-1815","repository":{"repo_id":"mtu","name":"Michigan Technological University","base_url":"https://digitalcommons.mtu.edu/do/oai/"},"display":{"title":"SVPWM SWITCHING PATTERN FOR Z-SOURCE INVERTER, SIMULATION AND APPLICATION","abstract":"The voltage source inverter (VSI) and current voltage source inverter (CSI) are widely used in industrial application. But the traditional VSIs and CSIs have one common problem: can’t boost or buck the voltage come from battery, which make them impossible to be used alone in Hybrid Electric Vehicle (HEV/EV) motor drive application, other issue is the traditional inverter need to add the dead-band time into the control sequence, but it will cause the output waveform distortion. This report presents an impedance source (Z-source network) topology to overcome these problems, it can use one stage instead of two stages (VSI or CSI + boost converter) to buck/boost the voltage come from battery in inverter system. Therefore, the Z-source topology hardware design can reduce switching element, entire system size and weight, minimize the system cost and increase the system efficiency. Also, a modified space vector pulse-width modulation (SVPWM) control method has been selected with the Z-source network together to achieve the best efficiency and lower total harmonic distortion (THD) at different modulation indexes. Finally, the Z-source inverter controlling will modulate under two control sequences: sinusoidal pulse width modulation (SPWM) and SVPWM, and their output voltage, ripple and THD will be compared.","abstract_html":"The voltage source inverter (VSI) and current voltage source inverter (CSI) are widely used in industrial application. But the traditional VSIs and CSIs have one common problem: can’t boost or buck the voltage come from battery, which make them impossible to be used alone in Hybrid Electric Vehicle (HEV/EV) motor drive application, other issue is the traditional inverter need to add the dead-band time into the control sequence, but it will cause the output waveform distortion. This report presents an impedance source (Z-source network) topology to overcome these problems, it can use one stage instead of two stages (VSI or CSI + boost converter) to buck/boost the voltage come from battery in inverter system. Therefore, the Z-source topology hardware design can reduce switching element, entire system size and weight, minimize the system cost and increase the system efficiency. Also, a modified space vector pulse-width modulation (SVPWM) control method has been selected with the Z-source network together to achieve the best efficiency and lower total harmonic distortion (THD) at different modulation indexes. Finally, the Z-source inverter controlling will modulate under two control sequences: sinusoidal pulse width modulation (SPWM) and SVPWM, and their output voltage, ripple and THD will be compared.","abstract_has_math":false,"creators":["Huang, Zhe"],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MS)","degree_level":"Master's report","degree_discipline":"Department of Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Wayne W. Weaver"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:16:02Z","subjects":["VSI","CSI","buck/boost","Z-source","SPWM","SVPWM","ripple","THD","Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.mtu.edu/etds/812"],"render_values":[{"text":"https://digitalcommons.mtu.edu/etds/812","href":"https://digitalcommons.mtu.edu/etds/812","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.37099/mtu.dc.etds/812","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.37099/mtu.dc.etds/812","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.mtu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.mtu.edu%3Aetds-1815","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wayne W. Weaver"]},{"key":"dc:creator","label":"Author","values":["Huang, Zhe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["VSI","CSI","buck/boost","Z-source","SPWM","SVPWM","ripple","THD","Electrical and Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.37099/mtu.dc.etds/812","https://digitalcommons.mtu.edu/etds/812"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The voltage source inverter (VSI) and current voltage source inverter (CSI) are widely used in industrial application. But the traditional VSIs and CSIs have one common problem: can’t boost or buck the voltage come from battery, which make them impossible to be used alone in Hybrid Electric Vehicle (HEV/EV) motor drive application, other issue is the traditional inverter need to add the dead-band time into the control sequence, but it will cause the output waveform distortion. This report presents an impedance source (Z-source network) topology to overcome these problems, it can use one stage instead of two stages (VSI or CSI + boost converter) to buck/boost the voltage come from battery in inverter system. Therefore, the Z-source topology hardware design can reduce switching element, entire system size and weight, minimize the system cost and increase the system efficiency. Also, a modified space vector pulse-width modulation (SVPWM) control method has been selected with the Z-source network together to achieve the best efficiency and lower total harmonic distortion (THD) at different modulation indexes. Finally, the Z-source inverter controlling will modulate under two control sequences: sinusoidal pulse width modulation (SPWM) and SVPWM, and their output voltage, ripple and THD will be compared."]},{"key":"dc:title","label":"Title","values":["SVPWM SWITCHING PATTERN FOR Z-SOURCE INVERTER, SIMULATION AND APPLICATION"]}]}],"canonical_facts":{"dc:contributor":["Wayne W. Weaver"],"dc:creator":["Huang, Zhe"],"dc:date.created":["2014-01-01T08:00:00Z"],"dc:description.abstract":["The voltage source inverter (VSI) and current voltage source inverter (CSI) are widely used in industrial application. But the traditional VSIs and CSIs have one common problem: can’t boost or buck the voltage come from battery, which make them impossible to be used alone in Hybrid Electric Vehicle (HEV/EV) motor drive application, other issue is the traditional inverter need to add the dead-band time into the control sequence, but it will cause the output waveform distortion. This report presents an impedance source (Z-source network) topology to overcome these problems, it can use one stage instead of two stages (VSI or CSI + boost converter) to buck/boost the voltage come from battery in inverter system. Therefore, the Z-source topology hardware design can reduce switching element, entire system size and weight, minimize the system cost and increase the system efficiency. Also, a modified space vector pulse-width modulation (SVPWM) control method has been selected with the Z-source network together to achieve the best efficiency and lower total harmonic distortion (THD) at different modulation indexes. Finally, the Z-source inverter controlling will modulate under two control sequences: sinusoidal pulse width modulation (SPWM) and SVPWM, and their output voltage, ripple and THD will be compared."],"dc:identifier":["10.37099/mtu.dc.etds/812","https://digitalcommons.mtu.edu/etds/812"],"dc:subject":["VSI","CSI","buck/boost","Z-source","SPWM","SVPWM","ripple","THD","Electrical and Computer Engineering"],"dc:title":["SVPWM SWITCHING PATTERN FOR Z-SOURCE INVERTER, SIMULATION AND APPLICATION"],"thesis:degree_discipline":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Master's report"],"thesis:degree_name":["Master of Science in Electrical Engineering (MS)"]},"updated_at":"2026-11-19T08:16:02Z"}