{"id":{"repo_id":"nanyang","oai_identifier":"oai:dr.ntu.edu.sg:10356/53675"},"canonical_url":"https://search.ndltd.org/etd/nanyang/oai:dr.ntu.edu.sg:10356/53675","repository":{"repo_id":"nanyang","name":"Nanyang Technological University","base_url":"https://dr.ntu.edu.sg/oai/request"},"display":{"title":"Comparative study of single-hole orifice and perforated plate for flow balancing in aircraft ECS","abstract":"This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers.","abstract_html":"This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers.","abstract_has_math":false,"creators":["Kurukulasuriya Ranga Prabath Dias."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"School of Mechanical and Aerospace Engineering","contributors":[],"advisors":["Tan Fock Lai"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-27T09:13:22Z","subjects":["DRNTU::Engineering::Aeronautical engineering"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10356/53675","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10356/53675","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ananyang%3Aoai%3Adr.ntu.edu.sg%3A10356%2F53675","prefix":"oai_dc"},"source_record":{"url":"https://dr.ntu.edu.sg/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adr.ntu.edu.sg%3A10356%2F53675","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.school","label":"School","values":["School of Mechanical and Aerospace Engineering"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Tan Fock Lai"]},{"key":"dc:creator","label":"Author","values":["Kurukulasuriya Ranga Prabath Dias."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-06-06T08:47:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-06-06T08:47:10Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2012"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["DRNTU::Engineering::Aeronautical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10356/53675"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c17f4cc6-a1bc-4cfa-98dd-05c112cdadf1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Comparative study of single-hole orifice and perforated plate for flow balancing in aircraft ECS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012</PublicationDate> <Authors> <Author> <DisplayName>Kurukulasuriya Ranga Prabath Dias.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>DRNTU::Engineering::Aeronautical engineering</Keyword> <Abstract>This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (Aerospace Engineering)"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["105 p."]},{"key":"dc:title","label":"Title","values":["Comparative study of single-hole orifice and perforated plate for flow balancing in aircraft ECS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c17f4cc6-a1bc-4cfa-98dd-05c112cdadf1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Comparative study of single-hole orifice and perforated plate for flow balancing in aircraft ECS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012</PublicationDate> <Authors> <Author> <DisplayName>Kurukulasuriya Ranga Prabath Dias.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>DRNTU::Engineering::Aeronautical engineering</Keyword> <Abstract>This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.school":["School of Mechanical and Aerospace Engineering"],"dc:contributor.supervisor":["Tan Fock Lai"],"dc:creator":["Kurukulasuriya Ranga Prabath Dias."],"dc:date.accessioned":["2013-06-06T08:47:10Z"],"dc:date.available":["2013-06-06T08:47:10Z"],"dc:date.copyright":["2012"],"dc:date.issued":["2012"],"dc:description.abstract":["This project simulates and compares the performance of two types of flow restrictors, namely single-hole orifice plate and a perforated plate with similar environmental control systems (ECS) of aircraft’s pressure and flow rate conditions which are ranged from 2988 Pa to 3735 Pa (12-15 inches of water) and 0.04719m3/s to 0.37755m3/s (100 to 800 CFM). The airflow models are studied using Computational Fluid Dynamic (CFD) solver ANSYS 13 and FLUENT with multiple models and varying characteristics, such as orifice geometry in terms of β ratio (dimensionless ratio of orifice hole diameter to pipe diameter ), pressure and inflow rate. The focus of the study is directed towards the change of Reynolds numbers commonly associated with pipeline transportation of air which is from 3,800 to 30,300 Reynolds numbers."],"dc:description.degree":["Master of Science (Aerospace Engineering)"],"dc:format.extent":["105 p."],"dc:identifier.uri":["http://hdl.handle.net/10356/53675"],"dc:language.iso":["en"],"dc:subject":["DRNTU::Engineering::Aeronautical engineering"],"dc:title":["Comparative study of single-hole orifice and perforated plate for flow balancing in aircraft ECS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-27T09:13:22Z"}