{"id":{"repo_id":"ndsu","oai_identifier":"oai:library.ndsu.edu:10365/26748"},"canonical_url":"https://search.ndltd.org/etd/ndsu/oai:library.ndsu.edu:10365/26748","repository":{"repo_id":"ndsu","name":"North Dakota State University","base_url":"https://library.ndsu.edu/server/oai/request"},"display":{"title":"A Comparative Study of Nitrification in Fargo and Moorhead Distribution Networks","abstract":"Nitrification in water distribution networks has become a growing concern for water supplies in the United States. The use of chloramines as a disinfectant in distribution pipe networks has become increasingly popular to reduce the disinfectant byproducts that are formed with free chlorine. In chloraminated systems there is potential for nitrification to occur because it reduces chloramine residuals. As chloramines decompose in the network, ammonia is released. Nitrifiers oxidize ammonia into nitrites, which react with chloramines resulting in its further reduction. As this cycle continues, chloramines will be consumed faster in the network, causing regrowth of heterotrophic bacteria. A study was conducted to compare the Fargo and Moorhead distribution networks for the occurrence of nitrification and their potential to deteriorate water quality. Each distribution network was analyzed independently for variations in operational conditions and water quality parameters that can serve as indications of nitrification in a distribution network.","abstract_html":"Nitrification in water distribution networks has become a growing concern for water supplies in the United States. The use of chloramines as a disinfectant in distribution pipe networks has become increasingly popular to reduce the disinfectant byproducts that are formed with free chlorine. In chloraminated systems there is potential for nitrification to occur because it reduces chloramine residuals. As chloramines decompose in the network, ammonia is released. Nitrifiers oxidize ammonia into nitrites, which react with chloramines resulting in its further reduction. As this cycle continues, chloramines will be consumed faster in the network, causing regrowth of heterotrophic bacteria. A study was conducted to compare the Fargo and Moorhead distribution networks for the occurrence of nitrification and their potential to deteriorate water quality. Each distribution network was analyzed independently for variations in operational conditions and water quality parameters that can serve as indications of nitrification in a distribution network.","abstract_has_math":false,"creators":["Portlock, Daniel"],"institution":"North Dakota State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T13:32:02Z","subjects":["Water distribution networks -- North Dakota -- Fargo","Water distribution networks -- Minnesota -- Moorhead","Nitrification"],"languages":[],"rights":["NDSU Policy 190.6.2"],"rights_urls":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10365/26748","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10365/26748","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://library.ndsu.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Alibrary.ndsu.edu%3A10365%2F26748","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Portlock, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-11-01T01:16:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-01T01:16:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["North Dakota State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water distribution networks -- North Dakota -- Fargo","Water distribution networks -- Minnesota -- Moorhead"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nitrification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["NDSU Policy 190.6.2"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://www.ndsu.edu/fileadmin/policy/190.pdf"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10365/26748"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Nitrification in water distribution networks has become a growing concern for water supplies in the United States. The use of chloramines as a disinfectant in distribution pipe networks has become increasingly popular to reduce the disinfectant byproducts that are formed with free chlorine. In chloraminated systems there is potential for nitrification to occur because it reduces chloramine residuals. As chloramines decompose in the network, ammonia is released. Nitrifiers oxidize ammonia into nitrites, which react with chloramines resulting in its further reduction. As this cycle continues, chloramines will be consumed faster in the network, causing regrowth of heterotrophic bacteria. A study was conducted to compare the Fargo and Moorhead distribution networks for the occurrence of nitrification and their potential to deteriorate water quality. Each distribution network was analyzed independently for variations in operational conditions and water quality parameters that can serve as indications of nitrification in a distribution network."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Moorhead Water Treatment Plant"]},{"key":"dc:title","label":"Title","values":["A Comparative Study of Nitrification in Fargo and Moorhead Distribution Networks"]}]}],"canonical_facts":{"dc:creator":["Portlock, Daniel"],"dc:date.accessioned":["2017-11-01T01:16:20Z"],"dc:date.available":["2017-11-01T01:16:20Z"],"dc:date.issued":["2012"],"dc:description.abstract":["Nitrification in water distribution networks has become a growing concern for water supplies in the United States. The use of chloramines as a disinfectant in distribution pipe networks has become increasingly popular to reduce the disinfectant byproducts that are formed with free chlorine. In chloraminated systems there is potential for nitrification to occur because it reduces chloramine residuals. As chloramines decompose in the network, ammonia is released. Nitrifiers oxidize ammonia into nitrites, which react with chloramines resulting in its further reduction. As this cycle continues, chloramines will be consumed faster in the network, causing regrowth of heterotrophic bacteria. A study was conducted to compare the Fargo and Moorhead distribution networks for the occurrence of nitrification and their potential to deteriorate water quality. Each distribution network was analyzed independently for variations in operational conditions and water quality parameters that can serve as indications of nitrification in a distribution network."],"dc:description.sponsorship":["Moorhead Water Treatment Plant"],"dc:identifier.uri":["https://hdl.handle.net/10365/26748"],"dc:publisher":["North Dakota State University"],"dc:rights":["NDSU Policy 190.6.2"],"dc:rights.uri":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"dc:subject":["Water distribution networks -- North Dakota -- Fargo","Water distribution networks -- Minnesota -- Moorhead"],"dc:subject.lcsh":["Nitrification"],"dc:title":["A Comparative Study of Nitrification in Fargo and Moorhead Distribution Networks"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T13:32:02Z"}