{"id":{"repo_id":"ndsu","oai_identifier":"oai:library.ndsu.edu:10365/27875"},"canonical_url":"https://search.ndltd.org/etd/ndsu/oai:library.ndsu.edu:10365/27875","repository":{"repo_id":"ndsu","name":"North Dakota State University","base_url":"https://library.ndsu.edu/server/oai/request"},"display":{"title":"The Effects of the Space Correction Kinesio Taping Method (R) on the Patellofemoral Joint Measured by Diagnostic Ultrasound","abstract":"Background: There is limited quantitative research on joint space measurements to support the use of Kinesio Tape Space Correction Method®. There is limited to no research regarding the use of diagnostic ultrasound to take a measurement of specific joint spaces. Methods: 32 subjects with bilaterally-healthy knees, no reported surgeries or reported allergies to Kinesio Tape®, reported their dominant knee to the researcher, who then measured their patellofemoral joint space with diagnostic ultrasound. Measurements were taken, the Kinesio Tape Space Correction Method® was applied, and left on for 10 minutes with the patient in a non-weight-bearing position. After 10 minutes, the joint space was re-measured. Results: There was a statistically significant difference (t[31]=2.823, p=.008) between pre-and post-taped patella to femur measurements. Conclusion: Results indicate that patellofemoral joint spaces can be increased by the Kinesio Tape Space Correction Method® after 10 minutes of application. Keywords: Kinesio Tape®, Diagnostic Ultrasound, Patellofemoral Joint Space","abstract_html":"Background: There is limited quantitative research on joint space measurements to support the use of Kinesio Tape Space Correction Method®. There is limited to no research regarding the use of diagnostic ultrasound to take a measurement of specific joint spaces. Methods: 32 subjects with bilaterally-healthy knees, no reported surgeries or reported allergies to Kinesio Tape®, reported their dominant knee to the researcher, who then measured their patellofemoral joint space with diagnostic ultrasound. Measurements were taken, the Kinesio Tape Space Correction Method® was applied, and left on for 10 minutes with the patient in a non-weight-bearing position. After 10 minutes, the joint space was re-measured. Results: There was a statistically significant difference (t[31]=2.823, p=.008) between pre-and post-taped patella to femur measurements. Conclusion: Results indicate that patellofemoral joint spaces can be increased by the Kinesio Tape Space Correction Method® after 10 minutes of application. Keywords: Kinesio Tape®, Diagnostic Ultrasound, Patellofemoral Joint Space","abstract_has_math":false,"creators":["Keister, Kassiann Deen"],"institution":"North Dakota State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T13:41:35Z","subjects":[],"languages":[],"rights":["NDSU Policy 190.6.2"],"rights_urls":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10365/27875","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10365/27875","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://library.ndsu.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Alibrary.ndsu.edu%3A10365%2F27875","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Keister, Kassiann Deen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-03-27T18:17:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-03-27T18:17:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["North Dakota State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["NDSU Policy 190.6.2"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://www.ndsu.edu/fileadmin/policy/190.pdf"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10365/27875"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: There is limited quantitative research on joint space measurements to support the use of Kinesio Tape Space Correction Method®. There is limited to no research regarding the use of diagnostic ultrasound to take a measurement of specific joint spaces. Methods: 32 subjects with bilaterally-healthy knees, no reported surgeries or reported allergies to Kinesio Tape®, reported their dominant knee to the researcher, who then measured their patellofemoral joint space with diagnostic ultrasound. Measurements were taken, the Kinesio Tape Space Correction Method® was applied, and left on for 10 minutes with the patient in a non-weight-bearing position. After 10 minutes, the joint space was re-measured. Results: There was a statistically significant difference (t[31]=2.823, p=.008) between pre-and post-taped patella to femur measurements. Conclusion: Results indicate that patellofemoral joint spaces can be increased by the Kinesio Tape Space Correction Method® after 10 minutes of application. Keywords: Kinesio Tape®, Diagnostic Ultrasound, Patellofemoral Joint Space"]},{"key":"dc:title","label":"Title","values":["The Effects of the Space Correction Kinesio Taping Method (R) on the Patellofemoral Joint Measured by Diagnostic Ultrasound"]}]}],"canonical_facts":{"dc:creator":["Keister, Kassiann Deen"],"dc:date.accessioned":["2018-03-27T18:17:51Z"],"dc:date.available":["2018-03-27T18:17:51Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Background: There is limited quantitative research on joint space measurements to support the use of Kinesio Tape Space Correction Method®. There is limited to no research regarding the use of diagnostic ultrasound to take a measurement of specific joint spaces. Methods: 32 subjects with bilaterally-healthy knees, no reported surgeries or reported allergies to Kinesio Tape®, reported their dominant knee to the researcher, who then measured their patellofemoral joint space with diagnostic ultrasound. Measurements were taken, the Kinesio Tape Space Correction Method® was applied, and left on for 10 minutes with the patient in a non-weight-bearing position. After 10 minutes, the joint space was re-measured. Results: There was a statistically significant difference (t[31]=2.823, p=.008) between pre-and post-taped patella to femur measurements. Conclusion: Results indicate that patellofemoral joint spaces can be increased by the Kinesio Tape Space Correction Method® after 10 minutes of application. Keywords: Kinesio Tape®, Diagnostic Ultrasound, Patellofemoral Joint Space"],"dc:identifier.uri":["https://hdl.handle.net/10365/27875"],"dc:publisher":["North Dakota State University"],"dc:rights":["NDSU Policy 190.6.2"],"dc:rights.uri":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"dc:title":["The Effects of the Space Correction Kinesio Taping Method (R) on the Patellofemoral Joint Measured by Diagnostic Ultrasound"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T13:41:35Z"}