{"id":{"repo_id":"ndsu","oai_identifier":"oai:library.ndsu.edu:10365/28837"},"canonical_url":"https://search.ndltd.org/etd/ndsu/oai:library.ndsu.edu:10365/28837","repository":{"repo_id":"ndsu","name":"North Dakota State University","base_url":"https://library.ndsu.edu/server/oai/request"},"display":{"title":"Impedance-Based Wireless Sensor Network for Metal-Protective Coating Evaluation","abstract":"Research has focused on the influences of flowing fluid on the corrosion of bare metals, but there is little emphasis on the degradation of metal-protective coating. Evaluating the metal-protective coating usually uses the Electrochemical Impedance Spectroscopy (EIS) method. This paper presents a new impedance-based wireless sensor network for metal-protective coating evaluation. This wireless sensor network consists of two parts: impedance-based wireless sensor nodes and a wireless data base that are equipped with a network analyzer (AD5933) and a RF transceiver (CC1111/CC1110). In the experiment, three coating panels are immersed in flowing deionized water (DI water) and one coating panel immersed in stationary DI water. Experimental results demonstrate that this wireless sensor network is capable of evaluating the coating degradation.","abstract_html":"Research has focused on the influences of flowing fluid on the corrosion of bare metals, but there is little emphasis on the degradation of metal-protective coating. Evaluating the metal-protective coating usually uses the Electrochemical Impedance Spectroscopy (EIS) method. This paper presents a new impedance-based wireless sensor network for metal-protective coating evaluation. This wireless sensor network consists of two parts: impedance-based wireless sensor nodes and a wireless data base that are equipped with a network analyzer (AD5933) and a RF transceiver (CC1111/CC1110). In the experiment, three coating panels are immersed in flowing deionized water (DI water) and one coating panel immersed in stationary DI water. Experimental results demonstrate that this wireless sensor network is capable of evaluating the coating degradation.","abstract_has_math":false,"creators":["Yu, Ronghua"],"institution":"North Dakota State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-19T13:46:36Z","subjects":["Wireless sensor networks.","Protective coatings -- Evaluation.","Metal coating -- Evaluation.","Corrosion and anti-corrosives -- Evaluation.","Impedance spectroscopy."],"languages":[],"rights":["NDSU Policy 190.6.2"],"rights_urls":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10365/28837","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10365/28837","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://library.ndsu.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Alibrary.ndsu.edu%3A10365%2F28837","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yu, Ronghua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-29T20:30:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-29T20:30:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["North Dakota State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Wireless sensor networks.","Protective coatings -- Evaluation.","Metal coating -- Evaluation.","Corrosion and anti-corrosives -- Evaluation.","Impedance spectroscopy."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["NDSU Policy 190.6.2"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://www.ndsu.edu/fileadmin/policy/190.pdf"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10365/28837"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Research has focused on the influences of flowing fluid on the corrosion of bare metals, but there is little emphasis on the degradation of metal-protective coating. Evaluating the metal-protective coating usually uses the Electrochemical Impedance Spectroscopy (EIS) method. This paper presents a new impedance-based wireless sensor network for metal-protective coating evaluation. This wireless sensor network consists of two parts: impedance-based wireless sensor nodes and a wireless data base that are equipped with a network analyzer (AD5933) and a RF transceiver (CC1111/CC1110). In the experiment, three coating panels are immersed in flowing deionized water (DI water) and one coating panel immersed in stationary DI water. Experimental results demonstrate that this wireless sensor network is capable of evaluating the coating degradation."]},{"key":"dc:title","label":"Title","values":["Impedance-Based Wireless Sensor Network for Metal-Protective Coating Evaluation"]}]}],"canonical_facts":{"dc:creator":["Yu, Ronghua"],"dc:date.accessioned":["2018-08-29T20:30:34Z"],"dc:date.available":["2018-08-29T20:30:34Z"],"dc:date.issued":["2011"],"dc:description.abstract":["Research has focused on the influences of flowing fluid on the corrosion of bare metals, but there is little emphasis on the degradation of metal-protective coating. Evaluating the metal-protective coating usually uses the Electrochemical Impedance Spectroscopy (EIS) method. This paper presents a new impedance-based wireless sensor network for metal-protective coating evaluation. This wireless sensor network consists of two parts: impedance-based wireless sensor nodes and a wireless data base that are equipped with a network analyzer (AD5933) and a RF transceiver (CC1111/CC1110). In the experiment, three coating panels are immersed in flowing deionized water (DI water) and one coating panel immersed in stationary DI water. Experimental results demonstrate that this wireless sensor network is capable of evaluating the coating degradation."],"dc:identifier.uri":["https://hdl.handle.net/10365/28837"],"dc:publisher":["North Dakota State University"],"dc:rights":["NDSU Policy 190.6.2"],"dc:rights.uri":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"dc:subject.lcsh":["Wireless sensor networks.","Protective coatings -- Evaluation.","Metal coating -- Evaluation.","Corrosion and anti-corrosives -- Evaluation.","Impedance spectroscopy."],"dc:title":["Impedance-Based Wireless Sensor Network for Metal-Protective Coating Evaluation"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T13:46:36Z"}