{"id":{"repo_id":"ndsu","oai_identifier":"oai:library.ndsu.edu:10365/34004"},"canonical_url":"https://search.ndltd.org/etd/ndsu/oai:library.ndsu.edu:10365/34004","repository":{"repo_id":"ndsu","name":"North Dakota State University","base_url":"https://library.ndsu.edu/server/oai/request"},"display":{"title":"On the Feasibility of Machine Learning Algorithms Towards Low-Cost Flow Cytometry","abstract":"Utilization low cost, scalable architectures for detection of specific cells for both mass flow and minute incidence analysis is something that is attractive for the clinical researcher, in order to expand access to otherwise costly devices. We demonstrate the use of a low-cost microfluidics device that performs detection of beads and cells, both for cell counting and for discrete cell type identification. This was accomplished using polymer technology via implementation of polydimethylsiloxane microfluidics, which were created by using a 3-D printed mold, and machine learning technologies with algorithms that can inference and track analyte particles within the microfluidic of interest. Our demonstration of our microfluidics device is proof that creating low cost instruments for analyte detection using current machine learning models and hardware is possible. We foresee the scalability of this design to be immense, in terms of throughput rate, inexpensiveness of product, and multiple different parameters and classes that can be searched for.","abstract_html":"Utilization low cost, scalable architectures for detection of specific cells for both mass flow and minute incidence analysis is something that is attractive for the clinical researcher, in order to expand access to otherwise costly devices. We demonstrate the use of a low-cost microfluidics device that performs detection of beads and cells, both for cell counting and for discrete cell type identification. This was accomplished using polymer technology via implementation of polydimethylsiloxane microfluidics, which were created by using a 3-D printed mold, and machine learning technologies with algorithms that can inference and track analyte particles within the microfluidic of interest. Our demonstration of our microfluidics device is proof that creating low cost instruments for analyte detection using current machine learning models and hardware is possible. We foresee the scalability of this design to be immense, in terms of throughput rate, inexpensiveness of product, and multiple different parameters and classes that can be searched for.","abstract_has_math":false,"creators":["Vandal, Noah"],"institution":"North Dakota State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08-01","date_published":"2023-08-01","updated_at":"2026-11-19T13:49:13Z","subjects":["classification","machine learning","microfluidics","segmentation"],"languages":[],"rights":["NDSU policy 190.6.2"],"rights_urls":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10365/34004","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10365/34004","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://library.ndsu.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Alibrary.ndsu.edu%3A10365%2F34004","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Vandal, Noah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-10-16T19:28:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-10-16T19:28:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-08-01"]},{"key":"dc:publisher","label":"Institution","values":["North Dakota State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["classification","machine learning","microfluidics","segmentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["NDSU policy 190.6.2"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://www.ndsu.edu/fileadmin/policy/190.pdf"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10365/34004"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Utilization low cost, scalable architectures for detection of specific cells for both mass flow and minute incidence analysis is something that is attractive for the clinical researcher, in order to expand access to otherwise costly devices. We demonstrate the use of a low-cost microfluidics device that performs detection of beads and cells, both for cell counting and for discrete cell type identification. This was accomplished using polymer technology via implementation of polydimethylsiloxane microfluidics, which were created by using a 3-D printed mold, and machine learning technologies with algorithms that can inference and track analyte particles within the microfluidic of interest. Our demonstration of our microfluidics device is proof that creating low cost instruments for analyte detection using current machine learning models and hardware is possible. We foresee the scalability of this design to be immense, in terms of throughput rate, inexpensiveness of product, and multiple different parameters and classes that can be searched for."]},{"key":"dc:title","label":"Title","values":["On the Feasibility of Machine Learning Algorithms Towards Low-Cost Flow Cytometry"]}]}],"canonical_facts":{"dc:creator":["Vandal, Noah"],"dc:date.accessioned":["2024-10-16T19:28:37Z"],"dc:date.available":["2024-10-16T19:28:37Z"],"dc:date.issued":["2023-08-01"],"dc:description.abstract":["Utilization low cost, scalable architectures for detection of specific cells for both mass flow and minute incidence analysis is something that is attractive for the clinical researcher, in order to expand access to otherwise costly devices. We demonstrate the use of a low-cost microfluidics device that performs detection of beads and cells, both for cell counting and for discrete cell type identification. This was accomplished using polymer technology via implementation of polydimethylsiloxane microfluidics, which were created by using a 3-D printed mold, and machine learning technologies with algorithms that can inference and track analyte particles within the microfluidic of interest. Our demonstration of our microfluidics device is proof that creating low cost instruments for analyte detection using current machine learning models and hardware is possible. We foresee the scalability of this design to be immense, in terms of throughput rate, inexpensiveness of product, and multiple different parameters and classes that can be searched for."],"dc:identifier.uri":["https://hdl.handle.net/10365/34004"],"dc:publisher":["North Dakota State University"],"dc:rights":["NDSU policy 190.6.2"],"dc:rights.uri":["https://www.ndsu.edu/fileadmin/policy/190.pdf"],"dc:subject":["classification","machine learning","microfluidics","segmentation"],"dc:title":["On the Feasibility of Machine Learning Algorithms Towards Low-Cost Flow Cytometry"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T13:49:13Z"}