{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:dissertations-2320"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:dissertations-2320","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Separation via multi-column pH parametric pumping","abstract":"This thesis presents the study of multi-column pH parametric pumping, a separation technique which applies the principle of parametric pumping and uses pH as control variable. Studies emphasize the mass transfer and the capability of separation by multi-column pH parametric pumping. Many operation modes of multi-column pH parapump are developed for varied objectives of separation. A Two-pH Levels Parapump is capable of enriching the product stream with solute components; a Three-pH Levels Parapump is capable of splitting components into two product streams. The separation capability of multi-column parapump is greatly superior to that of single-column parapump. As compared to cycling zone operation, parametric pumping gives a higher separation factor. Hemoglobin and albumin are chosen for the experimental model system to demonstrate the separation capability of multi-column pH parametric pumping, and to verify the predictability of the models. Presented are the theoretical basis, mathematical models and methods, results of experimental studies and computer exploration, and the correlation of data with models.","abstract_html":"This thesis presents the study of multi-column pH parametric pumping, a separation technique which applies the principle of parametric pumping and uses pH as control variable. Studies emphasize the mass transfer and the capability of separation by multi-column pH parametric pumping. Many operation modes of multi-column pH parapump are developed for varied objectives of separation. A Two-pH Levels Parapump is capable of enriching the product stream with solute components; a Three-pH Levels Parapump is capable of splitting components into two product streams. The separation capability of multi-column parapump is greatly superior to that of single-column parapump. As compared to cycling zone operation, parametric pumping gives a higher separation factor. Hemoglobin and albumin are chosen for the experimental model system to demonstrate the separation capability of multi-column pH parametric pumping, and to verify the predictability of the models. Presented are the theoretical basis, mathematical models and methods, results of experimental studies and computer exploration, and the correlation of data with models.","abstract_has_math":false,"creators":["Yang, Wei Tai"],"institution":null,"degree_name":"Doctor of Engineering Science in Chemical Engineering","degree_level":null,"degree_discipline":"Chemical Engineering and Chemistry","degree_department":null,"school":null,"contributors":["Hung T. Chen","Deran Hanesian","Dimitrios P. Tassios"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:53Z","subjects":["Separation (Technology)","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/dissertations/1265","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/dissertations/1265","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Adissertations-2320","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hung T. Chen","Deran Hanesian","Dimitrios P. Tassios"]},{"key":"dc:creator","label":"Author","values":["Yang, Wei Tai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1981-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering and Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Engineering Science in Chemical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Separation (Technology)","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/dissertations/1265"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the study of multi-column pH parametric pumping, a separation technique which applies the principle of parametric pumping and uses pH as control variable. Studies emphasize the mass transfer and the capability of separation by multi-column pH parametric pumping. Many operation modes of multi-column pH parapump are developed for varied objectives of separation. A Two-pH Levels Parapump is capable of enriching the product stream with solute components; a Three-pH Levels Parapump is capable of splitting components into two product streams. The separation capability of multi-column parapump is greatly superior to that of single-column parapump. As compared to cycling zone operation, parametric pumping gives a higher separation factor. Hemoglobin and albumin are chosen for the experimental model system to demonstrate the separation capability of multi-column pH parametric pumping, and to verify the predictability of the models. Presented are the theoretical basis, mathematical models and methods, results of experimental studies and computer exploration, and the correlation of data with models."]},{"key":"dc:title","label":"Title","values":["Separation via multi-column pH parametric pumping"]}]}],"canonical_facts":{"dc:contributor":["Hung T. Chen","Deran Hanesian","Dimitrios P. Tassios"],"dc:creator":["Yang, Wei Tai"],"dc:date.created":["1981-05-31T07:00:00Z"],"dc:description.abstract":["This thesis presents the study of multi-column pH parametric pumping, a separation technique which applies the principle of parametric pumping and uses pH as control variable. Studies emphasize the mass transfer and the capability of separation by multi-column pH parametric pumping. Many operation modes of multi-column pH parapump are developed for varied objectives of separation. A Two-pH Levels Parapump is capable of enriching the product stream with solute components; a Three-pH Levels Parapump is capable of splitting components into two product streams. The separation capability of multi-column parapump is greatly superior to that of single-column parapump. As compared to cycling zone operation, parametric pumping gives a higher separation factor. Hemoglobin and albumin are chosen for the experimental model system to demonstrate the separation capability of multi-column pH parametric pumping, and to verify the predictability of the models. Presented are the theoretical basis, mathematical models and methods, results of experimental studies and computer exploration, and the correlation of data with models."],"dc:identifier":["https://digitalcommons.njit.edu/dissertations/1265"],"dc:subject":["Separation (Technology)","Chemical Engineering"],"dc:title":["Separation via multi-column pH parametric pumping"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Chemical Engineering and Chemistry"],"thesis:degree_name":["Doctor of Engineering Science in Chemical Engineering"]},"updated_at":"2026-11-19T08:40:53Z"}