{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1759"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1759","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Programmable latching probe microstructures for wafer testing applications","abstract":"The objective of this thesis is to design a programmable wafer testing array on a single chip based on micro electromechanical systems (MEMS) and VLSI. The wafer-scale integration in this thesis is a programmable array of test probes that are used for engineering test of VLSI and ULSI silicon integrated circuits at the wafer level. This consists of two subsystems (1) the VLSI address circuits used for addressing and controlling the MEMS on the chip and (2) the latching probe MEMS microstructure array that actuates into position for testing VLSI wafers. Each of the subsystems have been designed, analyzed and simulated separately. These structures were then integrated into a demonstration 4x4 array forming a programmable probe card. A 3-micrometer critical dimension is used for both the VLSI CMOS and the MEMS physical design layouts. The fabrication technique for the MEMS microstructure is detailed. A standard 12-mask CMOS technology is used for the fabrication of the address circuits.","abstract_html":"The objective of this thesis is to design a programmable wafer testing array on a single chip based on micro electromechanical systems (MEMS) and VLSI. The wafer-scale integration in this thesis is a programmable array of test probes that are used for engineering test of VLSI and ULSI silicon integrated circuits at the wafer level. This consists of two subsystems (1) the VLSI address circuits used for addressing and controlling the MEMS on the chip and (2) the latching probe MEMS microstructure array that actuates into position for testing VLSI wafers. Each of the subsystems have been designed, analyzed and simulated separately. These structures were then integrated into a demonstration 4x4 array forming a programmable probe card. A 3-micrometer critical dimension is used for both the VLSI CMOS and the MEMS physical design layouts. The fabrication technique for the MEMS microstructure is detailed. A standard 12-mask CMOS technology is used for the fabrication of the address circuits.","abstract_has_math":false,"creators":["Sadeq, Salima Taifa"],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["William N. Carr","Roy H. Cornely","Edip Niver"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:39:53Z","subjects":["Programmable wafer testing array","Micro Electromechanical systems (MEMS)","VLSI","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/760","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/760","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-1759","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["William N. Carr","Roy H. Cornely","Edip Niver"]},{"key":"dc:creator","label":"Author","values":["Sadeq, Salima Taifa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2000-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Programmable wafer testing array","Micro Electromechanical systems (MEMS)","VLSI","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/760"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis is to design a programmable wafer testing array on a single chip based on micro electromechanical systems (MEMS) and VLSI. The wafer-scale integration in this thesis is a programmable array of test probes that are used for engineering test of VLSI and ULSI silicon integrated circuits at the wafer level. This consists of two subsystems (1) the VLSI address circuits used for addressing and controlling the MEMS on the chip and (2) the latching probe MEMS microstructure array that actuates into position for testing VLSI wafers. Each of the subsystems have been designed, analyzed and simulated separately. These structures were then integrated into a demonstration 4x4 array forming a programmable probe card. A 3-micrometer critical dimension is used for both the VLSI CMOS and the MEMS physical design layouts. The fabrication technique for the MEMS microstructure is detailed. A standard 12-mask CMOS technology is used for the fabrication of the address circuits."]},{"key":"dc:title","label":"Title","values":["Programmable latching probe microstructures for wafer testing applications"]}]}],"canonical_facts":{"dc:contributor":["William N. Carr","Roy H. Cornely","Edip Niver"],"dc:creator":["Sadeq, Salima Taifa"],"dc:date.created":["2000-05-31T07:00:00Z"],"dc:description.abstract":["The objective of this thesis is to design a programmable wafer testing array on a single chip based on micro electromechanical systems (MEMS) and VLSI. The wafer-scale integration in this thesis is a programmable array of test probes that are used for engineering test of VLSI and ULSI silicon integrated circuits at the wafer level. This consists of two subsystems (1) the VLSI address circuits used for addressing and controlling the MEMS on the chip and (2) the latching probe MEMS microstructure array that actuates into position for testing VLSI wafers. Each of the subsystems have been designed, analyzed and simulated separately. These structures were then integrated into a demonstration 4x4 array forming a programmable probe card. A 3-micrometer critical dimension is used for both the VLSI CMOS and the MEMS physical design layouts. The fabrication technique for the MEMS microstructure is detailed. A standard 12-mask CMOS technology is used for the fabrication of the address circuits."],"dc:identifier":["https://digitalcommons.njit.edu/theses/760"],"dc:subject":["Programmable wafer testing array","Micro Electromechanical systems (MEMS)","VLSI","Electrical and Electronics"],"dc:title":["Programmable latching probe microstructures for wafer testing applications"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:39:53Z"}