{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1830"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1830","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Biomechanical study of performance of a plugged femoral implant coupled with a trochanter cable system using finite element analysis","abstract":"A Finite Element Analysis was conducted to determine the effect of a plug on the performance of the critical section of a femoral implant coupled with a trochanter cable grip system. The critical section was defined near the proximal end of the stem where a hole was designed for the purpose of attaching the cable grip system. Two models were generated for the analysis. One consisted of the critical section with the grip cables and a plug filled in the hole and the other was without the plug. The models were based on design specifications provided by Howmedica Incorporated. Two types of simulations were performed on each model. The static simulation represented the instant the hip is subjected to ftill \"heel strike\" loading conditions during a normal walking cycle. The quasi-dynamic simulations represented two critical subphases of stance (\"heel strike\" and \"foot flat\") where the maximum loads were exerted on the implant. A normal walking speed of 4 km/h was used in the analysis. The cables around the hole were pre-tensioned. Both static and quasi-dynarnic results showed that the von Mises stress concentrations in the plugged model were lower than those in the non-plugged model. That is, a plug added to the hole of a femoral implant adjoined with a cable grip system reduced the critical stress around the hole. In addition, stress distributions within the implant were also altered due to the plug: it shifted the stress concentration away from the hole. Thus, these led to an enhancement in the performance of the implant.","abstract_html":"A Finite Element Analysis was conducted to determine the effect of a plug on the performance of the critical section of a femoral implant coupled with a trochanter cable grip system. The critical section was defined near the proximal end of the stem where a hole was designed for the purpose of attaching the cable grip system. Two models were generated for the analysis. One consisted of the critical section with the grip cables and a plug filled in the hole and the other was without the plug. The models were based on design specifications provided by Howmedica Incorporated. Two types of simulations were performed on each model. The static simulation represented the instant the hip is subjected to ftill &quot;heel strike&quot; loading conditions during a normal walking cycle. The quasi-dynamic simulations represented two critical subphases of stance (&quot;heel strike&quot; and &quot;foot flat&quot;) where the maximum loads were exerted on the implant. A normal walking speed of 4 km/h was used in the analysis. The cables around the hole were pre-tensioned. Both static and quasi-dynarnic results showed that the von Mises stress concentrations in the plugged model were lower than those in the non-plugged model. That is, a plug added to the hole of a femoral implant adjoined with a cable grip system reduced the critical stress around the hole. In addition, stress distributions within the implant were also altered due to the plug: it shifted the stress concentration away from the hole. Thus, these led to an enhancement in the performance of the implant.","abstract_has_math":false,"creators":["Carstarphen, Deanna Yvonne"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Taiming Chu","Micheal W. Dudasik","J. Russell Parsons"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:14Z","subjects":["Femoral implant","Trochanter cable grip system","Von Mises stress concentrations","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/831","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/831","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-1830","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Taiming Chu","Micheal W. Dudasik","J. Russell Parsons"]},{"key":"dc:creator","label":"Author","values":["Carstarphen, Deanna Yvonne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1999-08-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Femoral implant","Trochanter cable grip system","Von Mises stress concentrations","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/831"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A Finite Element Analysis was conducted to determine the effect of a plug on the performance of the critical section of a femoral implant coupled with a trochanter cable grip system. The critical section was defined near the proximal end of the stem where a hole was designed for the purpose of attaching the cable grip system. Two models were generated for the analysis. One consisted of the critical section with the grip cables and a plug filled in the hole and the other was without the plug. The models were based on design specifications provided by Howmedica Incorporated. Two types of simulations were performed on each model. The static simulation represented the instant the hip is subjected to ftill \"heel strike\" loading conditions during a normal walking cycle. The quasi-dynamic simulations represented two critical subphases of stance (\"heel strike\" and \"foot flat\") where the maximum loads were exerted on the implant. A normal walking speed of 4 km/h was used in the analysis. The cables around the hole were pre-tensioned. Both static and quasi-dynarnic results showed that the von Mises stress concentrations in the plugged model were lower than those in the non-plugged model. That is, a plug added to the hole of a femoral implant adjoined with a cable grip system reduced the critical stress around the hole. In addition, stress distributions within the implant were also altered due to the plug: it shifted the stress concentration away from the hole. Thus, these led to an enhancement in the performance of the implant."]},{"key":"dc:title","label":"Title","values":["Biomechanical study of performance of a plugged femoral implant coupled with a trochanter cable system using finite element analysis"]}]}],"canonical_facts":{"dc:contributor":["Taiming Chu","Micheal W. Dudasik","J. Russell Parsons"],"dc:creator":["Carstarphen, Deanna Yvonne"],"dc:date.created":["1999-08-31T07:00:00Z"],"dc:description.abstract":["A Finite Element Analysis was conducted to determine the effect of a plug on the performance of the critical section of a femoral implant coupled with a trochanter cable grip system. The critical section was defined near the proximal end of the stem where a hole was designed for the purpose of attaching the cable grip system. Two models were generated for the analysis. One consisted of the critical section with the grip cables and a plug filled in the hole and the other was without the plug. The models were based on design specifications provided by Howmedica Incorporated. Two types of simulations were performed on each model. The static simulation represented the instant the hip is subjected to ftill \"heel strike\" loading conditions during a normal walking cycle. The quasi-dynamic simulations represented two critical subphases of stance (\"heel strike\" and \"foot flat\") where the maximum loads were exerted on the implant. A normal walking speed of 4 km/h was used in the analysis. The cables around the hole were pre-tensioned. Both static and quasi-dynarnic results showed that the von Mises stress concentrations in the plugged model were lower than those in the non-plugged model. That is, a plug added to the hole of a femoral implant adjoined with a cable grip system reduced the critical stress around the hole. In addition, stress distributions within the implant were also altered due to the plug: it shifted the stress concentration away from the hole. Thus, these led to an enhancement in the performance of the implant."],"dc:identifier":["https://digitalcommons.njit.edu/theses/831"],"dc:subject":["Femoral implant","Trochanter cable grip system","Von Mises stress concentrations","Mechanical Engineering"],"dc:title":["Biomechanical study of performance of a plugged femoral implant coupled with a trochanter cable system using finite element analysis"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["Master of Science in Mechanical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:40:14Z"}