{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1868"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1868","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Mutual interference investigation of CEBus and X-10 powerline signaling","abstract":"Powerline control signaling using CEBus has great potential towards inexpensive home automation. CEBus transmits at 10 kBps using spread spectrum in the 100-400 kHz band while X-l0 sends 60 Bps using bursts of 120 kHz carrier on the power line. However, these two signals may destructively interfere when present simultaneously. X-10 is narrow band and interferes with the CEBus spread spectrum signal. This thesis looks into the mutual interference patterns of Power Line CEBus communication in the presence of X-l0 module signaling and visa versa. The investigation encompasses a series of tests and measurements on a Power Line CEBus-X10 test bed. The test bed allows progressively attenuated signal levels of X-10 to interact with CEBus and vice versa. Thus, the probability of success of CEBus and X-10 packets were studied at various levels of CEBus and X-10 in absolute as well as in relative terms in the ranges of approximately 0 to 20 dB. In general, the CEBus signal obstructs the X-10 signal. Weak strength X-l0 does not have any effect on CEBus, but a weak strength CEBus does have a discernable adverse effect on X- 10. For the same levels of attenuation, CEBus packets have a higher probability of survival than X- 10, which can be attributed to the processing gain inherent to the CEBus spead spectrum signaling as well as to the lower detection threshold level of CEBus with respect to X-l0. However, when a strong X- 10 signal interferes with a weak CEBus signal some probability of CEBus packet loss was observed. Simulation studies further illuminated the interference behavior of the CEBus X-l0 cohabitating signals under that scenario.","abstract_html":"Powerline control signaling using CEBus has great potential towards inexpensive home automation. CEBus transmits at 10 kBps using spread spectrum in the 100-400 kHz band while X-l0 sends 60 Bps using bursts of 120 kHz carrier on the power line. However, these two signals may destructively interfere when present simultaneously. X-10 is narrow band and interferes with the CEBus spread spectrum signal. This thesis looks into the mutual interference patterns of Power Line CEBus communication in the presence of X-l0 module signaling and visa versa. The investigation encompasses a series of tests and measurements on a Power Line CEBus-X10 test bed. The test bed allows progressively attenuated signal levels of X-10 to interact with CEBus and vice versa. Thus, the probability of success of CEBus and X-10 packets were studied at various levels of CEBus and X-10 in absolute as well as in relative terms in the ranges of approximately 0 to 20 dB. In general, the CEBus signal obstructs the X-10 signal. Weak strength X-l0 does not have any effect on CEBus, but a weak strength CEBus does have a discernable adverse effect on X- 10. For the same levels of attenuation, CEBus packets have a higher probability of survival than X- 10, which can be attributed to the processing gain inherent to the CEBus spead spectrum signaling as well as to the lower detection threshold level of CEBus with respect to X-l0. However, when a strong X- 10 signal interferes with a weak CEBus signal some probability of CEBus packet loss was observed. Simulation studies further illuminated the interference behavior of the CEBus X-l0 cohabitating signals under that scenario.","abstract_has_math":false,"creators":["Pallithotungal, Sajid"],"institution":null,"degree_name":"Master of Science in Telecommunications - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Constantine N. Manikopoulos","Yun Q. Shi","Dionissios Karvelas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:14Z","subjects":["Household electronics.","Local area networks (Computer networks)","Digital Communications and Networking"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/869","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/869","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-1868","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Constantine N. Manikopoulos","Yun Q. Shi","Dionissios Karvelas"]},{"key":"dc:creator","label":"Author","values":["Pallithotungal, Sajid"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1999-08-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Telecommunications - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Household electronics.","Local area networks (Computer networks)","Digital Communications and Networking"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/869"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Powerline control signaling using CEBus has great potential towards inexpensive home automation. CEBus transmits at 10 kBps using spread spectrum in the 100-400 kHz band while X-l0 sends 60 Bps using bursts of 120 kHz carrier on the power line. However, these two signals may destructively interfere when present simultaneously. X-10 is narrow band and interferes with the CEBus spread spectrum signal. This thesis looks into the mutual interference patterns of Power Line CEBus communication in the presence of X-l0 module signaling and visa versa. The investigation encompasses a series of tests and measurements on a Power Line CEBus-X10 test bed. The test bed allows progressively attenuated signal levels of X-10 to interact with CEBus and vice versa. Thus, the probability of success of CEBus and X-10 packets were studied at various levels of CEBus and X-10 in absolute as well as in relative terms in the ranges of approximately 0 to 20 dB. In general, the CEBus signal obstructs the X-10 signal. Weak strength X-l0 does not have any effect on CEBus, but a weak strength CEBus does have a discernable adverse effect on X- 10. For the same levels of attenuation, CEBus packets have a higher probability of survival than X- 10, which can be attributed to the processing gain inherent to the CEBus spead spectrum signaling as well as to the lower detection threshold level of CEBus with respect to X-l0. However, when a strong X- 10 signal interferes with a weak CEBus signal some probability of CEBus packet loss was observed. Simulation studies further illuminated the interference behavior of the CEBus X-l0 cohabitating signals under that scenario."]},{"key":"dc:title","label":"Title","values":["Mutual interference investigation of CEBus and X-10 powerline signaling"]}]}],"canonical_facts":{"dc:contributor":["Constantine N. Manikopoulos","Yun Q. Shi","Dionissios Karvelas"],"dc:creator":["Pallithotungal, Sajid"],"dc:date.created":["1999-08-31T07:00:00Z"],"dc:description.abstract":["Powerline control signaling using CEBus has great potential towards inexpensive home automation. CEBus transmits at 10 kBps using spread spectrum in the 100-400 kHz band while X-l0 sends 60 Bps using bursts of 120 kHz carrier on the power line. However, these two signals may destructively interfere when present simultaneously. X-10 is narrow band and interferes with the CEBus spread spectrum signal. This thesis looks into the mutual interference patterns of Power Line CEBus communication in the presence of X-l0 module signaling and visa versa. The investigation encompasses a series of tests and measurements on a Power Line CEBus-X10 test bed. The test bed allows progressively attenuated signal levels of X-10 to interact with CEBus and vice versa. Thus, the probability of success of CEBus and X-10 packets were studied at various levels of CEBus and X-10 in absolute as well as in relative terms in the ranges of approximately 0 to 20 dB. In general, the CEBus signal obstructs the X-10 signal. Weak strength X-l0 does not have any effect on CEBus, but a weak strength CEBus does have a discernable adverse effect on X- 10. For the same levels of attenuation, CEBus packets have a higher probability of survival than X- 10, which can be attributed to the processing gain inherent to the CEBus spead spectrum signaling as well as to the lower detection threshold level of CEBus with respect to X-l0. However, when a strong X- 10 signal interferes with a weak CEBus signal some probability of CEBus packet loss was observed. Simulation studies further illuminated the interference behavior of the CEBus X-l0 cohabitating signals under that scenario."],"dc:identifier":["https://digitalcommons.njit.edu/theses/869"],"dc:subject":["Household electronics.","Local area networks (Computer networks)","Digital Communications and Networking"],"dc:title":["Mutual interference investigation of CEBus and X-10 powerline signaling"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Telecommunications - (M.S.)"]},"updated_at":"2026-11-19T08:40:14Z"}