{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1902"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1902","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Radiative properties of silicon","abstract":"The objective of this thesis was 1) to study the radiative properties of silicon in the wavelength range of 1 to 20 microns and temperature range of 30 to 1000 C for the development of a multi-wavelength pyrometer 2) to develop a [sic] methodologies for deconvolution of the measured optical properties to yield fundamental optical constants of bulk materials. A novel spectral emissometer has been utilized for measurement of the temperature dependent radiative properties of silicon. The temperature determination capability of the emissometer was tested and verified using a standard thermocouple embedded in a silicon wafer. The temperature measurement accuracy, with the emissometer, was found to be within +/- 10 C of the thermocouple temperature for a temperature range of 30 to 300 C. The experimental results presented in this thesis showed that the measurement of high temperature optical properties could be performed reliably with a novel non-contact, real-time approach using the spectral emissometer. The optical properties of n and p-type lightly and heavily doped silicon wafers were investigated. These studies have led us to establish spectral emissometer as a reliable technique for simultaneous measurements of radiative properties and temperature in the 1-20 um wavelength range.","abstract_html":"The objective of this thesis was 1) to study the radiative properties of silicon in the wavelength range of 1 to 20 microns and temperature range of 30 to 1000 C for the development of a multi-wavelength pyrometer 2) to develop a [sic] methodologies for deconvolution of the measured optical properties to yield fundamental optical constants of bulk materials. A novel spectral emissometer has been utilized for measurement of the temperature dependent radiative properties of silicon. The temperature determination capability of the emissometer was tested and verified using a standard thermocouple embedded in a silicon wafer. The temperature measurement accuracy, with the emissometer, was found to be within +/- 10 C of the thermocouple temperature for a temperature range of 30 to 300 C. The experimental results presented in this thesis showed that the measurement of high temperature optical properties could be performed reliably with a novel non-contact, real-time approach using the spectral emissometer. The optical properties of n and p-type lightly and heavily doped silicon wafers were investigated. These studies have led us to establish spectral emissometer as a reliable technique for simultaneous measurements of radiative properties and temperature in the 1-20 um wavelength range.","abstract_has_math":false,"creators":["Patel, Anamika"],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["N. M. Ravindra","Kenneth Sohn","Edwin Hou"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:14Z","subjects":["Silicon--Thermal Properties","Silicon--Optical Properties","Drinking Water Purification","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/903","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/903","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-1902","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["N. M. Ravindra","Kenneth Sohn","Edwin Hou"]},{"key":"dc:creator","label":"Author","values":["Patel, Anamika"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1998-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Silicon--Thermal Properties","Silicon--Optical Properties","Drinking Water Purification","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/903"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis was 1) to study the radiative properties of silicon in the wavelength range of 1 to 20 microns and temperature range of 30 to 1000 C for the development of a multi-wavelength pyrometer 2) to develop a [sic] methodologies for deconvolution of the measured optical properties to yield fundamental optical constants of bulk materials. A novel spectral emissometer has been utilized for measurement of the temperature dependent radiative properties of silicon. The temperature determination capability of the emissometer was tested and verified using a standard thermocouple embedded in a silicon wafer. The temperature measurement accuracy, with the emissometer, was found to be within +/- 10 C of the thermocouple temperature for a temperature range of 30 to 300 C. The experimental results presented in this thesis showed that the measurement of high temperature optical properties could be performed reliably with a novel non-contact, real-time approach using the spectral emissometer. The optical properties of n and p-type lightly and heavily doped silicon wafers were investigated. These studies have led us to establish spectral emissometer as a reliable technique for simultaneous measurements of radiative properties and temperature in the 1-20 um wavelength range."]},{"key":"dc:title","label":"Title","values":["Radiative properties of silicon"]}]}],"canonical_facts":{"dc:contributor":["N. M. Ravindra","Kenneth Sohn","Edwin Hou"],"dc:creator":["Patel, Anamika"],"dc:date.created":["1998-05-31T07:00:00Z"],"dc:description.abstract":["The objective of this thesis was 1) to study the radiative properties of silicon in the wavelength range of 1 to 20 microns and temperature range of 30 to 1000 C for the development of a multi-wavelength pyrometer 2) to develop a [sic] methodologies for deconvolution of the measured optical properties to yield fundamental optical constants of bulk materials. A novel spectral emissometer has been utilized for measurement of the temperature dependent radiative properties of silicon. The temperature determination capability of the emissometer was tested and verified using a standard thermocouple embedded in a silicon wafer. The temperature measurement accuracy, with the emissometer, was found to be within +/- 10 C of the thermocouple temperature for a temperature range of 30 to 300 C. The experimental results presented in this thesis showed that the measurement of high temperature optical properties could be performed reliably with a novel non-contact, real-time approach using the spectral emissometer. The optical properties of n and p-type lightly and heavily doped silicon wafers were investigated. These studies have led us to establish spectral emissometer as a reliable technique for simultaneous measurements of radiative properties and temperature in the 1-20 um wavelength range."],"dc:identifier":["https://digitalcommons.njit.edu/theses/903"],"dc:subject":["Silicon--Thermal Properties","Silicon--Optical Properties","Drinking Water Purification","Electrical and Electronics"],"dc:title":["Radiative properties of silicon"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:40:14Z"}