{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1957"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1957","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Development and field testing of pulse introduction membrane extraction (PIME) for measurement of ground water contamination","abstract":"VOCs are a class of aromatic and aliphatic compounds with a variety of functional groups, and are in general detrimental to human health even at trace levels. Conventional analysis of VOCs in groundwater usually involves sampling at site followed by laboratory analysis. This results in long turn around times, high cost and also errors associated with sample preservation during transportation and storage. In order to address these problems, a field portable instrument referred to as Pulse Introduction Membrane Extraction (PIME) has been developed for monitoring trace level halogenated organic contaminants in ground water. A membrane extraction approach has been used, to selectively extract and concentrate the organics from a complex aqueous matrix with no additional sample preparation, thereby attaining high sensitivity and low detection limits. Using a field portable gas chromatography, analysis of individual discrete as well as continuous on-line monitoring of VOCs in groundwater was performed at a Superfund site. The results of the field test demonstrated that the field-PIME could provide real-time, cost-effective data for site assessment and rapid decision-making. The results from field-PIME analysis were in good agreement with that from a certified reference laboratory. Statistical analysis of this comparative data is also presented.","abstract_html":"VOCs are a class of aromatic and aliphatic compounds with a variety of functional groups, and are in general detrimental to human health even at trace levels. Conventional analysis of VOCs in groundwater usually involves sampling at site followed by laboratory analysis. This results in long turn around times, high cost and also errors associated with sample preservation during transportation and storage. In order to address these problems, a field portable instrument referred to as Pulse Introduction Membrane Extraction (PIME) has been developed for monitoring trace level halogenated organic contaminants in ground water. A membrane extraction approach has been used, to selectively extract and concentrate the organics from a complex aqueous matrix with no additional sample preparation, thereby attaining high sensitivity and low detection limits. Using a field portable gas chromatography, analysis of individual discrete as well as continuous on-line monitoring of VOCs in groundwater was performed at a Superfund site. The results of the field test demonstrated that the field-PIME could provide real-time, cost-effective data for site assessment and rapid decision-making. The results from field-PIME analysis were in good agreement with that from a certified reference laboratory. Statistical analysis of this comparative data is also presented.","abstract_has_math":false,"creators":["San Juan, Anthony"],"institution":null,"degree_name":"Master of Science in Applied Chemistry - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["S. Mitra","Barbara B. Kebbekus","Carol A. Venanzi"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:21Z","subjects":["Water pollution.","Membrane separation.","Volatile organic compounds.","Chemistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/958","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/958","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-1957","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["S. Mitra","Barbara B. Kebbekus","Carol A. Venanzi"]},{"key":"dc:creator","label":"Author","values":["San Juan, Anthony"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1998-08-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Chemistry - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water pollution.","Membrane separation.","Volatile organic compounds.","Chemistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["VOCs are a class of aromatic and aliphatic compounds with a variety of functional groups, and are in general detrimental to human health even at trace levels. Conventional analysis of VOCs in groundwater usually involves sampling at site followed by laboratory analysis. This results in long turn around times, high cost and also errors associated with sample preservation during transportation and storage. In order to address these problems, a field portable instrument referred to as Pulse Introduction Membrane Extraction (PIME) has been developed for monitoring trace level halogenated organic contaminants in ground water. A membrane extraction approach has been used, to selectively extract and concentrate the organics from a complex aqueous matrix with no additional sample preparation, thereby attaining high sensitivity and low detection limits. Using a field portable gas chromatography, analysis of individual discrete as well as continuous on-line monitoring of VOCs in groundwater was performed at a Superfund site. The results of the field test demonstrated that the field-PIME could provide real-time, cost-effective data for site assessment and rapid decision-making. The results from field-PIME analysis were in good agreement with that from a certified reference laboratory. Statistical analysis of this comparative data is also presented."]},{"key":"dc:title","label":"Title","values":["Development and field testing of pulse introduction membrane extraction (PIME) for measurement of ground water contamination"]}]}],"canonical_facts":{"dc:contributor":["S. Mitra","Barbara B. Kebbekus","Carol A. Venanzi"],"dc:creator":["San Juan, Anthony"],"dc:date.created":["1998-08-31T07:00:00Z"],"dc:description.abstract":["VOCs are a class of aromatic and aliphatic compounds with a variety of functional groups, and are in general detrimental to human health even at trace levels. Conventional analysis of VOCs in groundwater usually involves sampling at site followed by laboratory analysis. This results in long turn around times, high cost and also errors associated with sample preservation during transportation and storage. In order to address these problems, a field portable instrument referred to as Pulse Introduction Membrane Extraction (PIME) has been developed for monitoring trace level halogenated organic contaminants in ground water. A membrane extraction approach has been used, to selectively extract and concentrate the organics from a complex aqueous matrix with no additional sample preparation, thereby attaining high sensitivity and low detection limits. Using a field portable gas chromatography, analysis of individual discrete as well as continuous on-line monitoring of VOCs in groundwater was performed at a Superfund site. The results of the field test demonstrated that the field-PIME could provide real-time, cost-effective data for site assessment and rapid decision-making. The results from field-PIME analysis were in good agreement with that from a certified reference laboratory. Statistical analysis of this comparative data is also presented."],"dc:identifier":["https://digitalcommons.njit.edu/theses/958"],"dc:subject":["Water pollution.","Membrane separation.","Volatile organic compounds.","Chemistry"],"dc:title":["Development and field testing of pulse introduction membrane extraction (PIME) for measurement of ground water contamination"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Applied Chemistry - (M.S.)"]},"updated_at":"2026-11-19T08:40:21Z"}