{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2002"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2002","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"An investigation into the feasibility of utilizing pneumatic ultrasonic devices coupled with pneumatic fracturing in enhancing removal of volatile organic compounds from soils","abstract":"A bench scale investigation was conducted in a Plexiglass ^{TM} Test cell 1 foot square by 2 feet in height, packed with 400 mesh sand to a density of 100 lb. /ft^3. The sand was contaminated with a mixture of 10% ethanol and 90% water by weight having a total weight of 11.1 pounds, before it was packed in the test cell. A geotextile 1/2 inch thick was used as a simulated fracture and was placed 3 inches from the bottom of the tank. A siren and a whistle were tested in this fracture. The data were divided into a transient, two phase flow region, and a falling rate region similar to drying theory analysis. Free moisture versus time data showed a 39.1% improvement for the siren and a 412.4% improvement for the whistle in the transient region, and a 69% improvement for the siren and a 455 % improvement for the whistle in the falling rate region. Concentration of ethanol versus time data showed a 62.9% improvement for the siren in the transient region and no comparison was established for the whistle. A 192.0% improvement for the siren and a 931.4 % improvement for the whistle were measured in the falling rate region. The average time to reach asymptotic value of 0.01 free moisture with the siren was reduced by 37% and greater than 74.3% with the whistle. The average time to reach an ethanol concentration of 1 ppmv was reduced by greater than 41.3% with the siren and by greater than 74% with the whistle.","abstract_html":"A bench scale investigation was conducted in a Plexiglass ^{TM} Test cell 1 foot square by 2 feet in height, packed with 400 mesh sand to a density of 100 lb. /ft^3. The sand was contaminated with a mixture of 10% ethanol and 90% water by weight having a total weight of 11.1 pounds, before it was packed in the test cell. A geotextile 1/2 inch thick was used as a simulated fracture and was placed 3 inches from the bottom of the tank. A siren and a whistle were tested in this fracture. The data were divided into a transient, two phase flow region, and a falling rate region similar to drying theory analysis. Free moisture versus time data showed a 39.1% improvement for the siren and a 412.4% improvement for the whistle in the transient region, and a 69% improvement for the siren and a 455 % improvement for the whistle in the falling rate region. Concentration of ethanol versus time data showed a 62.9% improvement for the siren in the transient region and no comparison was established for the whistle. A 192.0% improvement for the siren and a 931.4 % improvement for the whistle were measured in the falling rate region. The average time to reach asymptotic value of 0.01 free moisture with the siren was reduced by 37% and greater than 74.3% with the whistle. The average time to reach an ethanol concentration of 1 ppmv was reduced by greater than 41.3% with the siren and by greater than 74% with the whistle.","abstract_has_math":false,"creators":["Fernandez, Hugo J."],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["Deran Hanesian","Angelo J. Perna","John R. Schuring"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:21Z","subjects":["Soil vapor extraction.","Volatile organic compounds.","Pneumatics.","Fracture mechanics.","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1003","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1003","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2002","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Deran Hanesian","Angelo J. Perna","John R. Schuring"]},{"key":"dc:creator","label":"Author","values":["Fernandez, Hugo J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1997-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Soil vapor extraction.","Volatile organic compounds.","Pneumatics.","Fracture mechanics.","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1003"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A bench scale investigation was conducted in a Plexiglass ^{TM} Test cell 1 foot square by 2 feet in height, packed with 400 mesh sand to a density of 100 lb. /ft^3. The sand was contaminated with a mixture of 10% ethanol and 90% water by weight having a total weight of 11.1 pounds, before it was packed in the test cell. A geotextile 1/2 inch thick was used as a simulated fracture and was placed 3 inches from the bottom of the tank. A siren and a whistle were tested in this fracture. The data were divided into a transient, two phase flow region, and a falling rate region similar to drying theory analysis. Free moisture versus time data showed a 39.1% improvement for the siren and a 412.4% improvement for the whistle in the transient region, and a 69% improvement for the siren and a 455 % improvement for the whistle in the falling rate region. Concentration of ethanol versus time data showed a 62.9% improvement for the siren in the transient region and no comparison was established for the whistle. A 192.0% improvement for the siren and a 931.4 % improvement for the whistle were measured in the falling rate region. The average time to reach asymptotic value of 0.01 free moisture with the siren was reduced by 37% and greater than 74.3% with the whistle. The average time to reach an ethanol concentration of 1 ppmv was reduced by greater than 41.3% with the siren and by greater than 74% with the whistle."]},{"key":"dc:title","label":"Title","values":["An investigation into the feasibility of utilizing pneumatic ultrasonic devices coupled with pneumatic fracturing in enhancing removal of volatile organic compounds from soils"]}]}],"canonical_facts":{"dc:contributor":["Deran Hanesian","Angelo J. Perna","John R. Schuring"],"dc:creator":["Fernandez, Hugo J."],"dc:date.created":["1997-05-31T07:00:00Z"],"dc:description.abstract":["A bench scale investigation was conducted in a Plexiglass ^{TM} Test cell 1 foot square by 2 feet in height, packed with 400 mesh sand to a density of 100 lb. /ft^3. The sand was contaminated with a mixture of 10% ethanol and 90% water by weight having a total weight of 11.1 pounds, before it was packed in the test cell. A geotextile 1/2 inch thick was used as a simulated fracture and was placed 3 inches from the bottom of the tank. A siren and a whistle were tested in this fracture. The data were divided into a transient, two phase flow region, and a falling rate region similar to drying theory analysis. Free moisture versus time data showed a 39.1% improvement for the siren and a 412.4% improvement for the whistle in the transient region, and a 69% improvement for the siren and a 455 % improvement for the whistle in the falling rate region. Concentration of ethanol versus time data showed a 62.9% improvement for the siren in the transient region and no comparison was established for the whistle. A 192.0% improvement for the siren and a 931.4 % improvement for the whistle were measured in the falling rate region. The average time to reach asymptotic value of 0.01 free moisture with the siren was reduced by 37% and greater than 74.3% with the whistle. The average time to reach an ethanol concentration of 1 ppmv was reduced by greater than 41.3% with the siren and by greater than 74% with the whistle."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1003"],"dc:subject":["Soil vapor extraction.","Volatile organic compounds.","Pneumatics.","Fracture mechanics.","Chemical Engineering"],"dc:title":["An investigation into the feasibility of utilizing pneumatic ultrasonic devices coupled with pneumatic fracturing in enhancing removal of volatile organic compounds from soils"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:40:21Z"}