{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2121"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2121","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"A new concept in artificial ligament and tendons modeling : finite element analysis","abstract":"Reconstruction of the Anterior Cruciate Ligament (ACL) has been a major focus in sports medicine for over twenty years. Severe or unrepairable damage of the ACL due to sport injury is a major problem faced by orthopedic surgeons and engineers. To successfully replace or reconstruct an injured ACL, the mechanical properties as well as the dimensional limitation of the material used must be similar to the biological ligaments. Although excessive literature describes experimental investigation on the mechanical property and clinical application of the ligament material, there is no analytical study that describes strains, stresses, and endurance in the bone/ligament/bone complex. The Finite Element Analysis (FEA) is a method to study this problem. The objectives of the present investigation are (1) to develop a finite element model (FEM) of an artificial ligament yarn, the emphasis is put on the development of the elastic FEM, (2) to analyze stress distribution in the ligament yarn fibers due to various loading conditions and designs, and (3) to compare results obtained from the FEA of the elastic model with results obtained from laboratory tensile test. Results obtained from the FEM model of the ACL prosthesis yarn are confirmed by experimental measurements.","abstract_html":"Reconstruction of the Anterior Cruciate Ligament (ACL) has been a major focus in sports medicine for over twenty years. Severe or unrepairable damage of the ACL due to sport injury is a major problem faced by orthopedic surgeons and engineers. To successfully replace or reconstruct an injured ACL, the mechanical properties as well as the dimensional limitation of the material used must be similar to the biological ligaments. Although excessive literature describes experimental investigation on the mechanical property and clinical application of the ligament material, there is no analytical study that describes strains, stresses, and endurance in the bone/ligament/bone complex. The Finite Element Analysis (FEA) is a method to study this problem. The objectives of the present investigation are (1) to develop a finite element model (FEM) of an artificial ligament yarn, the emphasis is put on the development of the elastic FEM, (2) to analyze stress distribution in the ligament yarn fibers due to various loading conditions and designs, and (3) to compare results obtained from the FEA of the elastic model with results obtained from laboratory tensile test. Results obtained from the FEM model of the ACL prosthesis yarn are confirmed by experimental measurements.","abstract_has_math":false,"creators":["Sokol, Miroslaw"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["Taiming Chu","Bernard Koplik","Edward Kin-Ming Wong"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:35Z","subjects":["Ligament prostheses.","Tendons.","Finite element method.","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1122","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1122","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2121","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Taiming Chu","Bernard Koplik","Edward Kin-Ming Wong"]},{"key":"dc:creator","label":"Author","values":["Sokol, Miroslaw"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1996-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ligament prostheses.","Tendons.","Finite element method.","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1122"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Reconstruction of the Anterior Cruciate Ligament (ACL) has been a major focus in sports medicine for over twenty years. Severe or unrepairable damage of the ACL due to sport injury is a major problem faced by orthopedic surgeons and engineers. To successfully replace or reconstruct an injured ACL, the mechanical properties as well as the dimensional limitation of the material used must be similar to the biological ligaments. Although excessive literature describes experimental investigation on the mechanical property and clinical application of the ligament material, there is no analytical study that describes strains, stresses, and endurance in the bone/ligament/bone complex. The Finite Element Analysis (FEA) is a method to study this problem. The objectives of the present investigation are (1) to develop a finite element model (FEM) of an artificial ligament yarn, the emphasis is put on the development of the elastic FEM, (2) to analyze stress distribution in the ligament yarn fibers due to various loading conditions and designs, and (3) to compare results obtained from the FEA of the elastic model with results obtained from laboratory tensile test. Results obtained from the FEM model of the ACL prosthesis yarn are confirmed by experimental measurements."]},{"key":"dc:title","label":"Title","values":["A new concept in artificial ligament and tendons modeling : finite element analysis"]}]}],"canonical_facts":{"dc:contributor":["Taiming Chu","Bernard Koplik","Edward Kin-Ming Wong"],"dc:creator":["Sokol, Miroslaw"],"dc:date.created":["1996-05-31T07:00:00Z"],"dc:description.abstract":["Reconstruction of the Anterior Cruciate Ligament (ACL) has been a major focus in sports medicine for over twenty years. Severe or unrepairable damage of the ACL due to sport injury is a major problem faced by orthopedic surgeons and engineers. To successfully replace or reconstruct an injured ACL, the mechanical properties as well as the dimensional limitation of the material used must be similar to the biological ligaments. Although excessive literature describes experimental investigation on the mechanical property and clinical application of the ligament material, there is no analytical study that describes strains, stresses, and endurance in the bone/ligament/bone complex. The Finite Element Analysis (FEA) is a method to study this problem. The objectives of the present investigation are (1) to develop a finite element model (FEM) of an artificial ligament yarn, the emphasis is put on the development of the elastic FEM, (2) to analyze stress distribution in the ligament yarn fibers due to various loading conditions and designs, and (3) to compare results obtained from the FEA of the elastic model with results obtained from laboratory tensile test. Results obtained from the FEM model of the ACL prosthesis yarn are confirmed by experimental measurements."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1122"],"dc:subject":["Ligament prostheses.","Tendons.","Finite element method.","Biomedical Engineering and Bioengineering"],"dc:title":["A new concept in artificial ligament and tendons modeling : finite element analysis"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:40:35Z"}