{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2265"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2265","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Tantalum silicide variable capacitance rotary micromotors : design and fabrication","abstract":"Tantalum silicide was studied as an alternative microelectromechanical material by fabricating a rotary micromotor utilizing a proven design. This material was used for the rotor, stators, and bearing over a silicon substrate. It has the attraction of potentially reducing the friction which is a major problem with polysilicon-to-polysilicon bearings. The necessity of high aspect ratio features required that a plasma or reactive ion etch with a high degree of anisotropy be developed to etch tantalum silicide films in excess of 1.5um. A sulfur hexafluoride/Freon 115 plasma provided the necessary process control during the etches. The stress present in annealed tantalum silicide films made it necessary to limit the maximum processing temperature to 300 C. These low temperature tantalum silicide films have thus far proved to be inadequate as a microelectromechanical material for the micromotor due to their inability to withstand the hydrofluoric acid release etch.","abstract_html":"Tantalum silicide was studied as an alternative microelectromechanical material by fabricating a rotary micromotor utilizing a proven design. This material was used for the rotor, stators, and bearing over a silicon substrate. It has the attraction of potentially reducing the friction which is a major problem with polysilicon-to-polysilicon bearings. The necessity of high aspect ratio features required that a plasma or reactive ion etch with a high degree of anisotropy be developed to etch tantalum silicide films in excess of 1.5um. A sulfur hexafluoride/Freon 115 plasma provided the necessary process control during the etches. The stress present in annealed tantalum silicide films made it necessary to limit the maximum processing temperature to 300 C. These low temperature tantalum silicide films have thus far proved to be inadequate as a microelectromechanical material for the micromotor due to their inability to withstand the hydrofluoric acid release etch.","abstract_has_math":false,"creators":["Berry, Michael Steven"],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:41Z","subjects":["Tantalum Silicide.","Capacitor motors--Design and construction.","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1266","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1266","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2265","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"]},{"key":"dc:creator","label":"Author","values":["Berry, Michael Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1993-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tantalum Silicide.","Capacitor motors--Design and construction.","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1266"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tantalum silicide was studied as an alternative microelectromechanical material by fabricating a rotary micromotor utilizing a proven design. This material was used for the rotor, stators, and bearing over a silicon substrate. It has the attraction of potentially reducing the friction which is a major problem with polysilicon-to-polysilicon bearings. The necessity of high aspect ratio features required that a plasma or reactive ion etch with a high degree of anisotropy be developed to etch tantalum silicide films in excess of 1.5um. A sulfur hexafluoride/Freon 115 plasma provided the necessary process control during the etches. The stress present in annealed tantalum silicide films made it necessary to limit the maximum processing temperature to 300 C. These low temperature tantalum silicide films have thus far proved to be inadequate as a microelectromechanical material for the micromotor due to their inability to withstand the hydrofluoric acid release etch."]},{"key":"dc:title","label":"Title","values":["Tantalum silicide variable capacitance rotary micromotors : design and fabrication"]}]}],"canonical_facts":{"dc:contributor":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"],"dc:creator":["Berry, Michael Steven"],"dc:date.created":["1993-05-31T07:00:00Z"],"dc:description.abstract":["Tantalum silicide was studied as an alternative microelectromechanical material by fabricating a rotary micromotor utilizing a proven design. This material was used for the rotor, stators, and bearing over a silicon substrate. It has the attraction of potentially reducing the friction which is a major problem with polysilicon-to-polysilicon bearings. The necessity of high aspect ratio features required that a plasma or reactive ion etch with a high degree of anisotropy be developed to etch tantalum silicide films in excess of 1.5um. A sulfur hexafluoride/Freon 115 plasma provided the necessary process control during the etches. The stress present in annealed tantalum silicide films made it necessary to limit the maximum processing temperature to 300 C. These low temperature tantalum silicide films have thus far proved to be inadequate as a microelectromechanical material for the micromotor due to their inability to withstand the hydrofluoric acid release etch."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1266"],"dc:subject":["Tantalum Silicide.","Capacitor motors--Design and construction.","Electrical and Electronics"],"dc:title":["Tantalum silicide variable capacitance rotary micromotors : design and fabrication"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:40:41Z"}