{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2320"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2320","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Acid recovery of cadmium and lead from immobilized activated sludge used to biosorb metals","abstract":"A study of the adsorption and subsequent desorption of heavy metals using various concentrations of hydrochloric acids has been performed. To accomplish this task, the following areas were investigated : immobilization of the sludge, adsorption of heavy metals, various concentrations of acid used as stripping agents, examination of the relative fractions of heavy metals obtained using various stripping agents, and the actual concentration of the acid at a particular fraction. It was observed that water helps in extraction of cadmium to a certain extent, but lead cannot be extracted with water. Also, water mixed with dilute hydrochloric acid is more efficient in extraction of metals as compared with direct addition of strong hydrochloric acid. It was also observed that nitric acid was not a very effective stripping agent as compared with hydrochloric acid.","abstract_html":"A study of the adsorption and subsequent desorption of heavy metals using various concentrations of hydrochloric acids has been performed. To accomplish this task, the following areas were investigated : immobilization of the sludge, adsorption of heavy metals, various concentrations of acid used as stripping agents, examination of the relative fractions of heavy metals obtained using various stripping agents, and the actual concentration of the acid at a particular fraction. It was observed that water helps in extraction of cadmium to a certain extent, but lead cannot be extracted with water. Also, water mixed with dilute hydrochloric acid is more efficient in extraction of metals as compared with direct addition of strong hydrochloric acid. It was also observed that nitric acid was not a very effective stripping agent as compared with hydrochloric acid.","abstract_has_math":false,"creators":["Hartman, Chandrakanth"],"institution":null,"degree_name":"Master of Science in Environmental Science - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["Samir S. Sofer","Richard B. Trattner","Henry Shaw"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:40:48Z","subjects":["Sewage--Purification--Heavy metals removal.","Heavy metals--Absorption and adsorption.","Cadmium.","Lead.","Environmental Sciences"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1321","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1321","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2320","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Samir S. Sofer","Richard B. Trattner","Henry Shaw"]},{"key":"dc:creator","label":"Author","values":["Hartman, Chandrakanth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1991-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Science - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sewage--Purification--Heavy metals removal.","Heavy metals--Absorption and adsorption.","Cadmium.","Lead.","Environmental Sciences"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A study of the adsorption and subsequent desorption of heavy metals using various concentrations of hydrochloric acids has been performed. To accomplish this task, the following areas were investigated : immobilization of the sludge, adsorption of heavy metals, various concentrations of acid used as stripping agents, examination of the relative fractions of heavy metals obtained using various stripping agents, and the actual concentration of the acid at a particular fraction. It was observed that water helps in extraction of cadmium to a certain extent, but lead cannot be extracted with water. Also, water mixed with dilute hydrochloric acid is more efficient in extraction of metals as compared with direct addition of strong hydrochloric acid. It was also observed that nitric acid was not a very effective stripping agent as compared with hydrochloric acid."]},{"key":"dc:title","label":"Title","values":["Acid recovery of cadmium and lead from immobilized activated sludge used to biosorb metals"]}]}],"canonical_facts":{"dc:contributor":["Samir S. Sofer","Richard B. Trattner","Henry Shaw"],"dc:creator":["Hartman, Chandrakanth"],"dc:date.created":["1991-05-31T07:00:00Z"],"dc:description.abstract":["A study of the adsorption and subsequent desorption of heavy metals using various concentrations of hydrochloric acids has been performed. To accomplish this task, the following areas were investigated : immobilization of the sludge, adsorption of heavy metals, various concentrations of acid used as stripping agents, examination of the relative fractions of heavy metals obtained using various stripping agents, and the actual concentration of the acid at a particular fraction. It was observed that water helps in extraction of cadmium to a certain extent, but lead cannot be extracted with water. Also, water mixed with dilute hydrochloric acid is more efficient in extraction of metals as compared with direct addition of strong hydrochloric acid. It was also observed that nitric acid was not a very effective stripping agent as compared with hydrochloric acid."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1321"],"dc:subject":["Sewage--Purification--Heavy metals removal.","Heavy metals--Absorption and adsorption.","Cadmium.","Lead.","Environmental Sciences"],"dc:title":["Acid recovery of cadmium and lead from immobilized activated sludge used to biosorb metals"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Environmental Science - (M.S.)"]},"updated_at":"2026-11-19T08:40:48Z"}