{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2481"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2481","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"The role of electrical noise in screening transformers prone to failure","abstract":"Insulation used as a barrier between the high voltage and low voltage windings of a transformer has sites of in- homogeneities like pinholes, cracks or voids, developed during the manufacturing process. Thus, these minute air pockets are stressed much more than the solid dielectric, on the application of a voltage stress, because the dielectric constant of the solid insulation is many times that of the air dielectric. As a result, excitation or ionization takes place in the air (gases). The amount of excited or ionized molecules is proportional to the volume of the inhomogenei- ties within the insulation. Therefore, experiments were conducted to monitor the electrical noise generated due to partial ionization of the tiny air gaps in the insulation. This was done by placing the transformer in a plexiglas tubing, around which an antenna was wound. The antenna was connected to a highly sensitive Hammerlund receiver, whose carrier level meter was calibrated in S-units. For 5S units of noise to be generated, the voltage stress required to be applied to the insulation was measured for a sample of three hundred transformers. The voltage readings were analyzed statistically and were found to have a normal distribution. Seven units which gave high voltage readings and seven units which gave low voltage. readings were subjected to accelerated life tests. This data has been analyzed statistically and has been found to be significant. The coefficient of correlation has been found and a linear regression equation has been formulated. The F-test of significance has been applied to the regression equation and has been found to be statistically significant.","abstract_html":"Insulation used as a barrier between the high voltage and low voltage windings of a transformer has sites of in- homogeneities like pinholes, cracks or voids, developed during the manufacturing process. Thus, these minute air pockets are stressed much more than the solid dielectric, on the application of a voltage stress, because the dielectric constant of the solid insulation is many times that of the air dielectric. As a result, excitation or ionization takes place in the air (gases). The amount of excited or ionized molecules is proportional to the volume of the inhomogenei- ties within the insulation. Therefore, experiments were conducted to monitor the electrical noise generated due to partial ionization of the tiny air gaps in the insulation. This was done by placing the transformer in a plexiglas tubing, around which an antenna was wound. The antenna was connected to a highly sensitive Hammerlund receiver, whose carrier level meter was calibrated in S-units. For 5S units of noise to be generated, the voltage stress required to be applied to the insulation was measured for a sample of three hundred transformers. The voltage readings were analyzed statistically and were found to have a normal distribution. Seven units which gave high voltage readings and seven units which gave low voltage. readings were subjected to accelerated life tests. This data has been analyzed statistically and has been found to be significant. The coefficient of correlation has been found and a linear regression equation has been formulated. The F-test of significance has been applied to the regression equation and has been found to be statistically significant.","abstract_has_math":false,"creators":["Shirodkar, Rajeev D."],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Raj Pratap Misra","Mauro Zambuto","W. H. Warren Ball"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:10Z","subjects":["Electronic noise.","Electric transformers.","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1482","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1482","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2481","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Raj Pratap Misra","Mauro Zambuto","W. H. Warren Ball"]},{"key":"dc:creator","label":"Author","values":["Shirodkar, Rajeev D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1983-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electronic noise.","Electric transformers.","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1482"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Insulation used as a barrier between the high voltage and low voltage windings of a transformer has sites of in- homogeneities like pinholes, cracks or voids, developed during the manufacturing process. Thus, these minute air pockets are stressed much more than the solid dielectric, on the application of a voltage stress, because the dielectric constant of the solid insulation is many times that of the air dielectric. As a result, excitation or ionization takes place in the air (gases). The amount of excited or ionized molecules is proportional to the volume of the inhomogenei- ties within the insulation. Therefore, experiments were conducted to monitor the electrical noise generated due to partial ionization of the tiny air gaps in the insulation. This was done by placing the transformer in a plexiglas tubing, around which an antenna was wound. The antenna was connected to a highly sensitive Hammerlund receiver, whose carrier level meter was calibrated in S-units. For 5S units of noise to be generated, the voltage stress required to be applied to the insulation was measured for a sample of three hundred transformers. The voltage readings were analyzed statistically and were found to have a normal distribution. Seven units which gave high voltage readings and seven units which gave low voltage. readings were subjected to accelerated life tests. This data has been analyzed statistically and has been found to be significant. The coefficient of correlation has been found and a linear regression equation has been formulated. The F-test of significance has been applied to the regression equation and has been found to be statistically significant."]},{"key":"dc:title","label":"Title","values":["The role of electrical noise in screening transformers prone to failure"]}]}],"canonical_facts":{"dc:contributor":["Raj Pratap Misra","Mauro Zambuto","W. H. Warren Ball"],"dc:creator":["Shirodkar, Rajeev D."],"dc:date.created":["1983-05-31T07:00:00Z"],"dc:description.abstract":["Insulation used as a barrier between the high voltage and low voltage windings of a transformer has sites of in- homogeneities like pinholes, cracks or voids, developed during the manufacturing process. Thus, these minute air pockets are stressed much more than the solid dielectric, on the application of a voltage stress, because the dielectric constant of the solid insulation is many times that of the air dielectric. As a result, excitation or ionization takes place in the air (gases). The amount of excited or ionized molecules is proportional to the volume of the inhomogenei- ties within the insulation. Therefore, experiments were conducted to monitor the electrical noise generated due to partial ionization of the tiny air gaps in the insulation. This was done by placing the transformer in a plexiglas tubing, around which an antenna was wound. The antenna was connected to a highly sensitive Hammerlund receiver, whose carrier level meter was calibrated in S-units. For 5S units of noise to be generated, the voltage stress required to be applied to the insulation was measured for a sample of three hundred transformers. The voltage readings were analyzed statistically and were found to have a normal distribution. Seven units which gave high voltage readings and seven units which gave low voltage. readings were subjected to accelerated life tests. This data has been analyzed statistically and has been found to be significant. The coefficient of correlation has been found and a linear regression equation has been formulated. The F-test of significance has been applied to the regression equation and has been found to be statistically significant."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1482"],"dc:subject":["Electronic noise.","Electric transformers.","Electrical and Electronics"],"dc:title":["The role of electrical noise in screening transformers prone to failure"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:10Z"}