{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2591"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2591","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Design, construction, and operation of water treatment plant residual monofills","abstract":"Due to the stringent environmental regulations, landfilling becomes the most viable option for ultimate disposal of water treatment plant (WTP) residues. At present, most states apply the regulations for municipal solid waste (MSW) landfills to the landfilling of WTP residues. This is too stringent since the WTP residues are not hazardous. Therefore, development of suitable criteria for WTP residual monofills is necessary and urgent. A set of environmental and geotechnical experiments was conducted to characterize WTP residues. It can be concluded that very little leachate will be produced and migration of leachate is unlikely. Also it was noted that insignificant amounts of biogas were produced in the tests conducted. Based on the investigations, it was observed that criteria applicable to MSW landfills regarding liners, leachate and groundwater monitoring systems and gas venting systems can be modified suitably for application to WTP monofills.","abstract_html":"Due to the stringent environmental regulations, landfilling becomes the most viable option for ultimate disposal of water treatment plant (WTP) residues. At present, most states apply the regulations for municipal solid waste (MSW) landfills to the landfilling of WTP residues. This is too stringent since the WTP residues are not hazardous. Therefore, development of suitable criteria for WTP residual monofills is necessary and urgent. A set of environmental and geotechnical experiments was conducted to characterize WTP residues. It can be concluded that very little leachate will be produced and migration of leachate is unlikely. Also it was noted that insignificant amounts of biogas were produced in the tests conducted. Based on the investigations, it was observed that criteria applicable to MSW landfills regarding liners, leachate and groundwater monitoring systems and gas venting systems can be modified suitably for application to WTP monofills.","abstract_has_math":false,"creators":["Bian, Haitao"],"institution":null,"degree_name":"Master of Science in Civil Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Dorairaja Raghu","Edward G. Dauenheimer","Hsin Neng Hsieh"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:16Z","subjects":["Water treatment plants--Design and construction.","Sanitary landfills.","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1592","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1592","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2591","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dorairaja Raghu","Edward G. Dauenheimer","Hsin Neng Hsieh"]},{"key":"dc:creator","label":"Author","values":["Bian, Haitao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1994-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water treatment plants--Design and construction.","Sanitary landfills.","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1592"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Due to the stringent environmental regulations, landfilling becomes the most viable option for ultimate disposal of water treatment plant (WTP) residues. At present, most states apply the regulations for municipal solid waste (MSW) landfills to the landfilling of WTP residues. This is too stringent since the WTP residues are not hazardous. Therefore, development of suitable criteria for WTP residual monofills is necessary and urgent. A set of environmental and geotechnical experiments was conducted to characterize WTP residues. It can be concluded that very little leachate will be produced and migration of leachate is unlikely. Also it was noted that insignificant amounts of biogas were produced in the tests conducted. Based on the investigations, it was observed that criteria applicable to MSW landfills regarding liners, leachate and groundwater monitoring systems and gas venting systems can be modified suitably for application to WTP monofills."]},{"key":"dc:title","label":"Title","values":["Design, construction, and operation of water treatment plant residual monofills"]}]}],"canonical_facts":{"dc:contributor":["Dorairaja Raghu","Edward G. Dauenheimer","Hsin Neng Hsieh"],"dc:creator":["Bian, Haitao"],"dc:date.created":["1994-01-31T08:00:00Z"],"dc:description.abstract":["Due to the stringent environmental regulations, landfilling becomes the most viable option for ultimate disposal of water treatment plant (WTP) residues. At present, most states apply the regulations for municipal solid waste (MSW) landfills to the landfilling of WTP residues. This is too stringent since the WTP residues are not hazardous. Therefore, development of suitable criteria for WTP residual monofills is necessary and urgent. A set of environmental and geotechnical experiments was conducted to characterize WTP residues. It can be concluded that very little leachate will be produced and migration of leachate is unlikely. Also it was noted that insignificant amounts of biogas were produced in the tests conducted. Based on the investigations, it was observed that criteria applicable to MSW landfills regarding liners, leachate and groundwater monitoring systems and gas venting systems can be modified suitably for application to WTP monofills."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1592"],"dc:subject":["Water treatment plants--Design and construction.","Sanitary landfills.","Civil Engineering"],"dc:title":["Design, construction, and operation of water treatment plant residual monofills"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Civil Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:16Z"}